Cargando…

Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants

The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted t...

Descripción completa

Detalles Bibliográficos
Autores principales: Ihde, Stefan, Pałka, Łukasz, Janeczek, Maciej, Kosior, Piotr, Kiryk, Jan, Dobrzyński, Maciej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5949185/
https://www.ncbi.nlm.nih.gov/pubmed/29854483
http://dx.doi.org/10.1155/2018/4671482
_version_ 1783322697604792320
author Ihde, Stefan
Pałka, Łukasz
Janeczek, Maciej
Kosior, Piotr
Kiryk, Jan
Dobrzyński, Maciej
author_facet Ihde, Stefan
Pałka, Łukasz
Janeczek, Maciej
Kosior, Piotr
Kiryk, Jan
Dobrzyński, Maciej
author_sort Ihde, Stefan
collection PubMed
description The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted to the clinic. Teeth 11 and 21 were extracted, and two long one-piece implants were inserted at extraction sockets in one surgical session under local anesthesia. Temporary composite crowns were placed in the patient on the same day. After 3 months, the single-phase two-layer impression was made and the composite crowns were replaced with metal-ceramic crowns. After 12 months, satisfactory aesthetic and functional results were obtained.
format Online
Article
Text
id pubmed-5949185
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-59491852018-05-31 Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants Ihde, Stefan Pałka, Łukasz Janeczek, Maciej Kosior, Piotr Kiryk, Jan Dobrzyński, Maciej Case Rep Dent Case Report The aim of this article was to present the clinical application of a new, smooth surfaced one-piece bicortical screw implant with immediate loading protocol. An 18-year-old, healthy male patient with a history of total dislocation and replantation of teeth 11 and 21 in early childhood was admitted to the clinic. Teeth 11 and 21 were extracted, and two long one-piece implants were inserted at extraction sockets in one surgical session under local anesthesia. Temporary composite crowns were placed in the patient on the same day. After 3 months, the single-phase two-layer impression was made and the composite crowns were replaced with metal-ceramic crowns. After 12 months, satisfactory aesthetic and functional results were obtained. Hindawi 2018-04-29 /pmc/articles/PMC5949185/ /pubmed/29854483 http://dx.doi.org/10.1155/2018/4671482 Text en Copyright © 2018 Stefan Ihde et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Ihde, Stefan
Pałka, Łukasz
Janeczek, Maciej
Kosior, Piotr
Kiryk, Jan
Dobrzyński, Maciej
Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title_full Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title_fullStr Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title_full_unstemmed Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title_short Bite Reconstruction in the Aesthetic Zone Using One-Piece Bicortical Screw Implants
title_sort bite reconstruction in the aesthetic zone using one-piece bicortical screw implants
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5949185/
https://www.ncbi.nlm.nih.gov/pubmed/29854483
http://dx.doi.org/10.1155/2018/4671482
work_keys_str_mv AT ihdestefan bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants
AT pałkałukasz bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants
AT janeczekmaciej bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants
AT kosiorpiotr bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants
AT kirykjan bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants
AT dobrzynskimaciej bitereconstructionintheaestheticzoneusingonepiecebicorticalscrewimplants