Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy

To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-...

Descripción completa

Detalles Bibliográficos
Autores principales: Yeap, P L, Noble, D J, Harrison, K, Bates, A M, Burnet, N G, Jena, R, Romanchikova, M, Sutcliffe, M P F, Thomas, S J, Barnett, G C, Benson, R J, Jefferies, S J, Parker, M A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IOP Publishing 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5952263/
https://www.ncbi.nlm.nih.gov/pubmed/28573978
http://dx.doi.org/10.1088/1361-6560/aa76aa
_version_ 1783323151387590656
author Yeap, P L
Noble, D J
Harrison, K
Bates, A M
Burnet, N G
Jena, R
Romanchikova, M
Sutcliffe, M P F
Thomas, S J
Barnett, G C
Benson, R J
Jefferies, S J
Parker, M A
author_facet Yeap, P L
Noble, D J
Harrison, K
Bates, A M
Burnet, N G
Jena, R
Romanchikova, M
Sutcliffe, M P F
Thomas, S J
Barnett, G C
Benson, R J
Jefferies, S J
Parker, M A
author_sort Yeap, P L
collection PubMed
description To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text] , and the median DBC is ([Formula: see text] ) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text] ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord.
format Online
Article
Text
id pubmed-5952263
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher IOP Publishing
record_format MEDLINE/PubMed
spelling pubmed-59522632018-05-18 Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy Yeap, P L Noble, D J Harrison, K Bates, A M Burnet, N G Jena, R Romanchikova, M Sutcliffe, M P F Thomas, S J Barnett, G C Benson, R J Jefferies, S J Parker, M A Phys Med Biol Paper To determine delivered dose to the spinal cord, a technique has been developed to propagate manual contours from kilovoltage computed-tomography (kVCT) scans for treatment planning to megavoltage computed-tomography (MVCT) guidance scans. The technique uses the Elastix software to perform intensity-based deformable image registration of each kVCT scan to the associated MVCT scans. The registration transform is then applied to contours of the spinal cord drawn manually on the kVCT scan, to obtain contour positions on the MVCT scans. Different registration strategies have been investigated, with performance evaluated by comparing the resulting auto-contours with manual contours, drawn by oncologists. The comparison metrics include the conformity index (CI), and the distance between centres (DBC). With optimised registration, auto-contours generally agree well with manual contours. Considering all 30 MVCT scans for each of three patients, the median CI is [Formula: see text] , and the median DBC is ([Formula: see text] ) mm. An intra-observer comparison for the same scans gives a median CI of [Formula: see text] and a DBC of ([Formula: see text] ) mm. Good levels of conformity are also obtained when auto-contours are compared with manual contours from one observer for a single MVCT scan for each of 30 patients, and when they are compared with manual contours from six observers for two MVCT scans for each of three patients. Using the auto-contours to estimate organ position at treatment time, a preliminary study of 33 patients who underwent radiotherapy for head-and-neck cancers indicates good agreement between planned and delivered dose to the spinal cord. IOP Publishing 2017-08-07 2017-07-12 /pmc/articles/PMC5952263/ /pubmed/28573978 http://dx.doi.org/10.1088/1361-6560/aa76aa Text en © 2017 Institute of Physics and Engineering in Medicine http://creativecommons.org/licenses/by/3.0/ Original content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence (http://creativecommons.org/licenses/by/3.0) . Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.
spellingShingle Paper
Yeap, P L
Noble, D J
Harrison, K
Bates, A M
Burnet, N G
Jena, R
Romanchikova, M
Sutcliffe, M P F
Thomas, S J
Barnett, G C
Benson, R J
Jefferies, S J
Parker, M A
Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title_full Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title_fullStr Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title_full_unstemmed Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title_short Automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
title_sort automatic contour propagation using deformable image registration to determine delivered dose to spinal cord in head-and-neck cancer radiotherapy
topic Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5952263/
https://www.ncbi.nlm.nih.gov/pubmed/28573978
http://dx.doi.org/10.1088/1361-6560/aa76aa
work_keys_str_mv AT yeappl automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT nobledj automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT harrisonk automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT batesam automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT burnetng automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT jenar automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT romanchikovam automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT sutcliffempf automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT thomassj automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT barnettgc automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT bensonrj automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT jefferiessj automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy
AT parkerma automaticcontourpropagationusingdeformableimageregistrationtodeterminedelivereddosetospinalcordinheadandneckcancerradiotherapy