Cargando…

Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering

INTRODUCTION: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. MATERIALS AND M...

Descripción completa

Detalles Bibliográficos
Autores principales: Qi, Jie, Zhang, Huang, Wang, Yingzhou, Mani, Mohan Prasath, Jaganathan, Saravana Kumar
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5955049/
https://www.ncbi.nlm.nih.gov/pubmed/29785105
http://dx.doi.org/10.2147/IJN.S151242
_version_ 1783323634967773184
author Qi, Jie
Zhang, Huang
Wang, Yingzhou
Mani, Mohan Prasath
Jaganathan, Saravana Kumar
author_facet Qi, Jie
Zhang, Huang
Wang, Yingzhou
Mani, Mohan Prasath
Jaganathan, Saravana Kumar
author_sort Qi, Jie
collection PubMed
description INTRODUCTION: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. MATERIALS AND METHODS: In this study, the hybrid scaffold based on polyvinyl alcohol (PVA) blended with metallocene polyethylene (mPE) and plectranthus amboinicus (PA) was fabricated for bone tissue engineering via electrospinning. The fabricated hybrid nanocomposites were characterized by scanning electron microscopy (SEM), Fourier transform and infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), contact angle measurement, and atomic force microscopy (AFM). Furthermore, activated partial thromboplastin time (APTT), prothrombin time (PT), and hemolytic assays were used to investigate the blood compatibility of the prepared hybrid nanocomposites. RESULTS: The prepared hybrid nanocomposites showed reduced fiber diameter (238±45 nm) and also increased porosity (87%) with decreased pore diameter (340±86 nm) compared with pure PVA. The interactions between PVA, mPE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa). The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs). CONCLUSION: The prepared nanocomposites exhibited better physico-chemical properties, sufficient porosity, mechanical strength, and blood compatibility, which favors it as a valuable candidate in bone tissue engineering for repairing the bone defects.
format Online
Article
Text
id pubmed-5955049
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-59550492018-05-21 Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering Qi, Jie Zhang, Huang Wang, Yingzhou Mani, Mohan Prasath Jaganathan, Saravana Kumar Int J Nanomedicine Original Research INTRODUCTION: Currently, the design of extracellular matrix (ECM) with nanoscale properties in bone tissue engineering is challenging. For bone tissue engineering, the ECM must have certain properties such as being nontoxic, highly porous, and should not cause foreign body reactions. MATERIALS AND METHODS: In this study, the hybrid scaffold based on polyvinyl alcohol (PVA) blended with metallocene polyethylene (mPE) and plectranthus amboinicus (PA) was fabricated for bone tissue engineering via electrospinning. The fabricated hybrid nanocomposites were characterized by scanning electron microscopy (SEM), Fourier transform and infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), contact angle measurement, and atomic force microscopy (AFM). Furthermore, activated partial thromboplastin time (APTT), prothrombin time (PT), and hemolytic assays were used to investigate the blood compatibility of the prepared hybrid nanocomposites. RESULTS: The prepared hybrid nanocomposites showed reduced fiber diameter (238±45 nm) and also increased porosity (87%) with decreased pore diameter (340±86 nm) compared with pure PVA. The interactions between PVA, mPE, and PA were identified by the formation of the additional peaks as revealed in FTIR. Furthermore, the prepared hybrid nanocomposites showed a decreased contact angle of 51°±1.32° indicating a hydrophilic nature and exhibited lower thermal stability compared to pristine PVA. Moreover, the mechanical results revealed that the electrospun scaffold showed an improved tensile strength of 3.55±0.29 MPa compared with the pristine PVA (1.8±0.52 MPa). The prepared hybrid nanocomposites showed delayed blood clotting as noted in APTT and PT assays indicating better blood compatibility. Moreover, the hemolysis assay revealed that the hybrid nanocomposites exhibited a low hemolytic index of 0.6% compared with pure PVA, which was 1.6% suggesting the safety of the developed nanocomposite to red blood cells (RBCs). CONCLUSION: The prepared nanocomposites exhibited better physico-chemical properties, sufficient porosity, mechanical strength, and blood compatibility, which favors it as a valuable candidate in bone tissue engineering for repairing the bone defects. Dove Medical Press 2018-05-11 /pmc/articles/PMC5955049/ /pubmed/29785105 http://dx.doi.org/10.2147/IJN.S151242 Text en © 2018 Qi et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Qi, Jie
Zhang, Huang
Wang, Yingzhou
Mani, Mohan Prasath
Jaganathan, Saravana Kumar
Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_full Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_fullStr Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_full_unstemmed Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_short Development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (PVA/mPE/PA) for bone tissue engineering
title_sort development and blood compatibility assessment of electrospun polyvinyl alcohol blended with metallocene polyethylene and plectranthus amboinicus (pva/mpe/pa) for bone tissue engineering
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5955049/
https://www.ncbi.nlm.nih.gov/pubmed/29785105
http://dx.doi.org/10.2147/IJN.S151242
work_keys_str_mv AT qijie developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT zhanghuang developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT wangyingzhou developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT manimohanprasath developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering
AT jaganathansaravanakumar developmentandbloodcompatibilityassessmentofelectrospunpolyvinylalcoholblendedwithmetallocenepolyethyleneandplectranthusamboinicuspvampepaforbonetissueengineering