Cargando…

Adjustments of haptics length for tilted intraocular lens after intrascleral fixation

PURPOSE: To report the findings and surgical techniques on two cases of severe tilting of an intraocular lens (IOL) that had been implanted with intrascleral fixation and the tilting was detected by anterior segment optical coherence tomography (AS-OCT). OBSERVATIONS: Two patients underwent flanged...

Descripción completa

Detalles Bibliográficos
Autores principales: Kurimori, Helena Yuri, Inoue, Makoto, Hirakata, Akito
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5956722/
https://www.ncbi.nlm.nih.gov/pubmed/29780933
http://dx.doi.org/10.1016/j.ajoc.2018.02.025
_version_ 1783323934300569600
author Kurimori, Helena Yuri
Inoue, Makoto
Hirakata, Akito
author_facet Kurimori, Helena Yuri
Inoue, Makoto
Hirakata, Akito
author_sort Kurimori, Helena Yuri
collection PubMed
description PURPOSE: To report the findings and surgical techniques on two cases of severe tilting of an intraocular lens (IOL) that had been implanted with intrascleral fixation and the tilting was detected by anterior segment optical coherence tomography (AS-OCT). OBSERVATIONS: Two patients underwent flanged intrascleral fixation of an IOL with the double needle technique. AS-OCT showed that the tilt of IOL was 25.3° in Case 1 and was 38.1° in Case 2, and a second surgery was planned to reduce the IOL tilt. Both edges of the flanged haptics were externalized and shortened by 2–3 mm. Then, the haptics edges were inserted intrasclerally. The tilt of the IOLs was reduced to 7.7° and 5.7°, and the myopia-shifted refraction was reduced from −2.75 diopters (D) and −4.50 D to −0.13 D and −0.50 D of the approximate planned refraction in the two cases. CONCLUSIONS AND IMPORTANCE: An excessive tilt of an intrasclerally fixed IOL can be corrected by shortening the length of the haptics. AS-OCT was useful in not only detecting the tilted IOL but also in monitoring the degree of tilt after adjustment surgery.
format Online
Article
Text
id pubmed-5956722
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-59567222018-05-18 Adjustments of haptics length for tilted intraocular lens after intrascleral fixation Kurimori, Helena Yuri Inoue, Makoto Hirakata, Akito Am J Ophthalmol Case Rep Case report PURPOSE: To report the findings and surgical techniques on two cases of severe tilting of an intraocular lens (IOL) that had been implanted with intrascleral fixation and the tilting was detected by anterior segment optical coherence tomography (AS-OCT). OBSERVATIONS: Two patients underwent flanged intrascleral fixation of an IOL with the double needle technique. AS-OCT showed that the tilt of IOL was 25.3° in Case 1 and was 38.1° in Case 2, and a second surgery was planned to reduce the IOL tilt. Both edges of the flanged haptics were externalized and shortened by 2–3 mm. Then, the haptics edges were inserted intrasclerally. The tilt of the IOLs was reduced to 7.7° and 5.7°, and the myopia-shifted refraction was reduced from −2.75 diopters (D) and −4.50 D to −0.13 D and −0.50 D of the approximate planned refraction in the two cases. CONCLUSIONS AND IMPORTANCE: An excessive tilt of an intrasclerally fixed IOL can be corrected by shortening the length of the haptics. AS-OCT was useful in not only detecting the tilted IOL but also in monitoring the degree of tilt after adjustment surgery. Elsevier 2018-03-01 /pmc/articles/PMC5956722/ /pubmed/29780933 http://dx.doi.org/10.1016/j.ajoc.2018.02.025 Text en © 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case report
Kurimori, Helena Yuri
Inoue, Makoto
Hirakata, Akito
Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title_full Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title_fullStr Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title_full_unstemmed Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title_short Adjustments of haptics length for tilted intraocular lens after intrascleral fixation
title_sort adjustments of haptics length for tilted intraocular lens after intrascleral fixation
topic Case report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5956722/
https://www.ncbi.nlm.nih.gov/pubmed/29780933
http://dx.doi.org/10.1016/j.ajoc.2018.02.025
work_keys_str_mv AT kurimorihelenayuri adjustmentsofhapticslengthfortiltedintraocularlensafterintrascleralfixation
AT inouemakoto adjustmentsofhapticslengthfortiltedintraocularlensafterintrascleralfixation
AT hirakataakito adjustmentsofhapticslengthfortiltedintraocularlensafterintrascleralfixation