Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation
BACKGROUND: In the last few years, there has been an increasing interest in the use of robotic devices to objectively quantify motor performance of patients after brain damage. Although these robot-derived measures can potentially add meaningful information about the patient’s dexterity, as well as...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5956822/ https://www.ncbi.nlm.nih.gov/pubmed/29769127 http://dx.doi.org/10.1186/s12984-018-0385-8 |
_version_ | 1783323958068641792 |
---|---|
author | Germanotta, Marco Cruciani, Arianna Pecchioli, Cristiano Loreti, Simona Spedicato, Albino Meotti, Matteo Mosca, Rita Speranza, Gabriele Cecchi, Francesca Giannarelli, Giorgia Padua, Luca Aprile, Irene |
author_facet | Germanotta, Marco Cruciani, Arianna Pecchioli, Cristiano Loreti, Simona Spedicato, Albino Meotti, Matteo Mosca, Rita Speranza, Gabriele Cecchi, Francesca Giannarelli, Giorgia Padua, Luca Aprile, Irene |
author_sort | Germanotta, Marco |
collection | PubMed |
description | BACKGROUND: In the last few years, there has been an increasing interest in the use of robotic devices to objectively quantify motor performance of patients after brain damage. Although these robot-derived measures can potentially add meaningful information about the patient’s dexterity, as well as be used as outcome measurements after the rehabilitation treatment, they need to be validated before being used in clinical practice. The present work aims to evaluate the reliability, the validity and the discriminant ability of the metrics provided by a novel robotic device for upper limb rehabilitation. METHODS: Forty-eight patients with sub-acute stroke and 40 age-matched healthy subjects were involved in this study. Clinical evaluation included: Fugl-Meyer Assessment for the upper limb, Action Research Arm Test, and Barthel Index. Robotic evaluation of the upper limb performance consisted of 14 measures of motor ability quantifying the dexterity in performing planar reaching movements. Patients were evaluated twice, one day apart, to assess the reliability of the robotic metrics, using the Intraclass Correlation Coefficient. Validity was assessed by analyzing the correlation of the robotic metrics with the clinical scales, by means of the Spearman’s Correlation Coefficient. Finally, the ability of the robotic metrics to distinguish between patients with stroke and healthy subjects was investigated with t-tests and the Effect Size. RESULTS: Reliability was found to be excellent for 12 measures and from moderate to good for the remaining 2. Most of the robotic indices were strongly correlated with the clinical scales, while a few showed a moderate correlation and only one was not correlated with the Barthel Index and weakly correlated with the remain two. Finally, all but one the provided metrics were able to discriminate between the two groups, with large effect sizes for most of them. CONCLUSION: We found that all the robotic indices except one provided by a novel robotic device for upper limb rehabilitation are reliable, sensitive and strongly correlated both with motor and disability clinical scales. Therefore, this device is suitable as evaluation tool for the upper limb motor performance of patients with sub-acute stroke in clinical practice. TRIAL REGISTRATION: NCT02879279. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12984-018-0385-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5956822 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-59568222018-05-24 Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation Germanotta, Marco Cruciani, Arianna Pecchioli, Cristiano Loreti, Simona Spedicato, Albino Meotti, Matteo Mosca, Rita Speranza, Gabriele Cecchi, Francesca Giannarelli, Giorgia Padua, Luca Aprile, Irene J Neuroeng Rehabil Research BACKGROUND: In the last few years, there has been an increasing interest in the use of robotic devices to objectively quantify motor performance of patients after brain damage. Although these robot-derived measures can potentially add meaningful information about the patient’s dexterity, as well as be used as outcome measurements after the rehabilitation treatment, they need to be validated before being used in clinical practice. The present work aims to evaluate the reliability, the validity and the discriminant ability of the metrics provided by a novel robotic device for upper limb rehabilitation. METHODS: Forty-eight patients with sub-acute stroke and 40 age-matched healthy subjects were involved in this study. Clinical evaluation included: Fugl-Meyer Assessment for the upper limb, Action Research Arm Test, and Barthel Index. Robotic evaluation of the upper limb performance consisted of 14 measures of motor ability quantifying the dexterity in performing planar reaching movements. Patients were evaluated twice, one day apart, to assess the reliability of the robotic metrics, using the Intraclass Correlation Coefficient. Validity was assessed by analyzing the correlation of the robotic metrics with the clinical scales, by means of the Spearman’s Correlation Coefficient. Finally, the ability of the robotic metrics to distinguish between patients with stroke and healthy subjects was investigated with t-tests and the Effect Size. RESULTS: Reliability was found to be excellent for 12 measures and from moderate to good for the remaining 2. Most of the robotic indices were strongly correlated with the clinical scales, while a few showed a moderate correlation and only one was not correlated with the Barthel Index and weakly correlated with the remain two. Finally, all but one the provided metrics were able to discriminate between the two groups, with large effect sizes for most of them. CONCLUSION: We found that all the robotic indices except one provided by a novel robotic device for upper limb rehabilitation are reliable, sensitive and strongly correlated both with motor and disability clinical scales. Therefore, this device is suitable as evaluation tool for the upper limb motor performance of patients with sub-acute stroke in clinical practice. TRIAL REGISTRATION: NCT02879279. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12984-018-0385-8) contains supplementary material, which is available to authorized users. BioMed Central 2018-05-16 /pmc/articles/PMC5956822/ /pubmed/29769127 http://dx.doi.org/10.1186/s12984-018-0385-8 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Germanotta, Marco Cruciani, Arianna Pecchioli, Cristiano Loreti, Simona Spedicato, Albino Meotti, Matteo Mosca, Rita Speranza, Gabriele Cecchi, Francesca Giannarelli, Giorgia Padua, Luca Aprile, Irene Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title | Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title_full | Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title_fullStr | Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title_full_unstemmed | Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title_short | Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
title_sort | reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5956822/ https://www.ncbi.nlm.nih.gov/pubmed/29769127 http://dx.doi.org/10.1186/s12984-018-0385-8 |
work_keys_str_mv | AT germanottamarco reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT crucianiarianna reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT pecchiolicristiano reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT loretisimona reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT spedicatoalbino reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT meottimatteo reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT moscarita reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT speranzagabriele reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT cecchifrancesca reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT giannarelligiorgia reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT padualuca reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation AT aprileirene reliabilityvalidityanddiscriminantabilityoftheinstrumentalindicesprovidedbyanovelplanarroboticdeviceforupperlimbrehabilitation |