Cargando…
Definition of fields margins for palliative radiotherapy of pancreatic carcinoma
The present study aimed to provide practical guidelines for palliative treatment of advanced carcinoma of the pancreas (CAP) with the 2D technique. Fifteen patients with locally advanced CAP consecutively treated with radiation therapy at the Radiation Oncology Center, Research and Care Foundation ‘...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
D.A. Spandidos
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5958799/ https://www.ncbi.nlm.nih.gov/pubmed/29844901 http://dx.doi.org/10.3892/mco.2018.1605 |
_version_ | 1783324293994643456 |
---|---|
author | Buwenge, Milly Marinelli, Alfonso Deodato, Francesco Macchia, Gabriella Wondemagegnhu, Tigeneh Salah, Tareq Cammelli, Silvia Uddin, A. F. M. Kamal Sumon, Mostafa A. Donati, Constanza M. Cilla, Savino Morganti, Alessio G. |
author_facet | Buwenge, Milly Marinelli, Alfonso Deodato, Francesco Macchia, Gabriella Wondemagegnhu, Tigeneh Salah, Tareq Cammelli, Silvia Uddin, A. F. M. Kamal Sumon, Mostafa A. Donati, Constanza M. Cilla, Savino Morganti, Alessio G. |
author_sort | Buwenge, Milly |
collection | PubMed |
description | The present study aimed to provide practical guidelines for palliative treatment of advanced carcinoma of the pancreas (CAP) with the 2D technique. Fifteen patients with locally advanced CAP consecutively treated with radiation therapy at the Radiation Oncology Center, Research and Care Foundation ‘Giovanni Paolo II’ (Campobasso, Italy) underwent computed tomography simulation in supine position. Definition of the clinical target volume (CTV) included the head and body of the pancreas, and the retropancreatic space. The planning target volume was defined by adding a margin of 14 mm to the CTV in the cranio-caudal direction and of 11 mm in radial direction. For each patient, 3 treatment plans were calculated using a cobalt source, 6 MV photons and 15 MV photons (box technique). Beams were drawn using the primary collimators without using multileaf collimators, and progressively optimized in order to respect the minimum dose (D(min)>90%) constraint. Once the final plan was achieved, distances of the fields edges from a set of reference points (bony or duodenal landmarks) were measured. Using this technique, 15 anterior-posterior and postero-anterior (AP-PA) beams and 15 pairs of lateral-lateral (LL) beams were defined for the different patients. Finally, the single minimal AP-PA and LL beams able to include the 15 sets of AP-PA and LL beams were defined. The results of this analysis are reported in tabular form. Guidelines are provided for treatment based on cobalt unit or Linear accelerator (both 6 and 15 MV photons). This study provides information regarding field size and position. A dosimetric study has been planned to identify the dose to be administered with this technique taking into account current dose-volume constraints. |
format | Online Article Text |
id | pubmed-5958799 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | D.A. Spandidos |
record_format | MEDLINE/PubMed |
spelling | pubmed-59587992018-05-29 Definition of fields margins for palliative radiotherapy of pancreatic carcinoma Buwenge, Milly Marinelli, Alfonso Deodato, Francesco Macchia, Gabriella Wondemagegnhu, Tigeneh Salah, Tareq Cammelli, Silvia Uddin, A. F. M. Kamal Sumon, Mostafa A. Donati, Constanza M. Cilla, Savino Morganti, Alessio G. Mol Clin Oncol Articles The present study aimed to provide practical guidelines for palliative treatment of advanced carcinoma of the pancreas (CAP) with the 2D technique. Fifteen patients with locally advanced CAP consecutively treated with radiation therapy at the Radiation Oncology Center, Research and Care Foundation ‘Giovanni Paolo II’ (Campobasso, Italy) underwent computed tomography simulation in supine position. Definition of the clinical target volume (CTV) included the head and body of the pancreas, and the retropancreatic space. The planning target volume was defined by adding a margin of 14 mm to the CTV in the cranio-caudal direction and of 11 mm in radial direction. For each patient, 3 treatment plans were calculated using a cobalt source, 6 MV photons and 15 MV photons (box technique). Beams were drawn using the primary collimators without using multileaf collimators, and progressively optimized in order to respect the minimum dose (D(min)>90%) constraint. Once the final plan was achieved, distances of the fields edges from a set of reference points (bony or duodenal landmarks) were measured. Using this technique, 15 anterior-posterior and postero-anterior (AP-PA) beams and 15 pairs of lateral-lateral (LL) beams were defined for the different patients. Finally, the single minimal AP-PA and LL beams able to include the 15 sets of AP-PA and LL beams were defined. The results of this analysis are reported in tabular form. Guidelines are provided for treatment based on cobalt unit or Linear accelerator (both 6 and 15 MV photons). This study provides information regarding field size and position. A dosimetric study has been planned to identify the dose to be administered with this technique taking into account current dose-volume constraints. D.A. Spandidos 2018-06 2018-04-12 /pmc/articles/PMC5958799/ /pubmed/29844901 http://dx.doi.org/10.3892/mco.2018.1605 Text en Copyright: © Buwenge et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made. |
spellingShingle | Articles Buwenge, Milly Marinelli, Alfonso Deodato, Francesco Macchia, Gabriella Wondemagegnhu, Tigeneh Salah, Tareq Cammelli, Silvia Uddin, A. F. M. Kamal Sumon, Mostafa A. Donati, Constanza M. Cilla, Savino Morganti, Alessio G. Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title | Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title_full | Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title_fullStr | Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title_full_unstemmed | Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title_short | Definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
title_sort | definition of fields margins for palliative radiotherapy of pancreatic carcinoma |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5958799/ https://www.ncbi.nlm.nih.gov/pubmed/29844901 http://dx.doi.org/10.3892/mco.2018.1605 |
work_keys_str_mv | AT buwengemilly definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT marinellialfonso definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT deodatofrancesco definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT macchiagabriella definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT wondemagegnhutigeneh definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT salahtareq definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT cammellisilvia definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT uddinafmkamal definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT sumonmostafaa definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT donaticonstanzam definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT cillasavino definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma AT morgantialessiog definitionoffieldsmarginsforpalliativeradiotherapyofpancreaticcarcinoma |