Cargando…

Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study

BACKGROUND: Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo m...

Descripción completa

Detalles Bibliográficos
Autores principales: Rao, Suman, Thankachan, Prashanth, Amrutur, Bharadwaj, Washington, Maryann, Mony, Prem K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5961490/
https://www.ncbi.nlm.nih.gov/pubmed/29796294
http://dx.doi.org/10.1186/s40814-018-0293-5
_version_ 1783324726959013888
author Rao, Suman
Thankachan, Prashanth
Amrutur, Bharadwaj
Washington, Maryann
Mony, Prem K.
author_facet Rao, Suman
Thankachan, Prashanth
Amrutur, Bharadwaj
Washington, Maryann
Mony, Prem K.
author_sort Rao, Suman
collection PubMed
description BACKGROUND: Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo mother care (KMC) adherence in a continuous and real-time manner remotely for several days’ duration in hospital and home settings. Using an innovative remote biomonitoring device to measure both temperature and baby position, we undertook a techno-feasibility study in preparation for a clinical trial. METHODS: We designed and developed a wearable sensor for tracking KMC adherence and neonatal temperature, using social innovation design principles. After screening mother-infant dyads using clinical and logistic eligibility criteria, we piloted this wearable sensor along with a gateway device and the commercial cellular network. The dyads were recruited during hospitalization and followed up in the hospital and home phases for several days. Simple descriptive statistical analysis was undertaken. RESULTS: Recruitment rate was 50% (6/12), and consenting rate was 83% (5/6) during a 2-month period. These five neonates contributed a total of 39 study days (15 hospital days and 24 home days). Their mean [± standard deviation (S.D.)] birth weight was 1490 (± 244) g. The mean (± S.D.) of the vital signs for the five babies was temperature [36.5 °C (± 0.3)], heart rate [146.5/min (± 14)], and oxygen saturation [94% (± 4)]. No severe or moderate side-effects were noted; one baby developed mild dermatitis under the device that was transient and self-limiting, yielding an incidence proportion of 20% and incidence rate of 2.6/100 person-days. None of the mothers reported any discomfort with the use of the device. Temperatures detected from 81 paired readings revealed that those from the wearable sensor were 0.2 °C lower than those detected by clinical thermometers [36.4 (± 0.7) vs 36.6 (± 0.3); < 0.001]. There was also iterative feedback that was useful for hardware and software design specifications of the wearable sensor, the gateway device, and the analytics platform. Lastly, lessons were learnt with regard to the logistics of research team interactions with healthcare professionals and study participants during the hospitalization and post-discharge home phases of the study. CONCLUSIONS: The pilot study has shown that it is feasible and acceptable to track KMC adherence as well as maternal and newborn temperatures in a potentially safe manner on a real-time mode for several days’ duration during hospitalization and home phases. The pilot has also helped inform modifications in clinical monitoring, technological modifications, and logistics planning in preparation for the definitive clinical trial. TRIAL REGISTRATION: Clinical Trials Registry of India, CTRI/2017/09/009789
format Online
Article
Text
id pubmed-5961490
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-59614902018-05-24 Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study Rao, Suman Thankachan, Prashanth Amrutur, Bharadwaj Washington, Maryann Mony, Prem K. Pilot Feasibility Stud Research BACKGROUND: Remote biomonitoring of vital parameters in hospitals and homes has the potential to improve coverage and quality of maternal and neonatal health. Wearable sensors coupled with modern information and communication technology now offer an opportunity to monitor temperatures and kangaroo mother care (KMC) adherence in a continuous and real-time manner remotely for several days’ duration in hospital and home settings. Using an innovative remote biomonitoring device to measure both temperature and baby position, we undertook a techno-feasibility study in preparation for a clinical trial. METHODS: We designed and developed a wearable sensor for tracking KMC adherence and neonatal temperature, using social innovation design principles. After screening mother-infant dyads using clinical and logistic eligibility criteria, we piloted this wearable sensor along with a gateway device and the commercial cellular network. The dyads were recruited during hospitalization and followed up in the hospital and home phases for several days. Simple descriptive statistical analysis was undertaken. RESULTS: Recruitment rate was 50% (6/12), and consenting rate was 83% (5/6) during a 2-month period. These five neonates contributed a total of 39 study days (15 hospital days and 24 home days). Their mean [± standard deviation (S.D.)] birth weight was 1490 (± 244) g. The mean (± S.D.) of the vital signs for the five babies was temperature [36.5 °C (± 0.3)], heart rate [146.5/min (± 14)], and oxygen saturation [94% (± 4)]. No severe or moderate side-effects were noted; one baby developed mild dermatitis under the device that was transient and self-limiting, yielding an incidence proportion of 20% and incidence rate of 2.6/100 person-days. None of the mothers reported any discomfort with the use of the device. Temperatures detected from 81 paired readings revealed that those from the wearable sensor were 0.2 °C lower than those detected by clinical thermometers [36.4 (± 0.7) vs 36.6 (± 0.3); < 0.001]. There was also iterative feedback that was useful for hardware and software design specifications of the wearable sensor, the gateway device, and the analytics platform. Lastly, lessons were learnt with regard to the logistics of research team interactions with healthcare professionals and study participants during the hospitalization and post-discharge home phases of the study. CONCLUSIONS: The pilot study has shown that it is feasible and acceptable to track KMC adherence as well as maternal and newborn temperatures in a potentially safe manner on a real-time mode for several days’ duration during hospitalization and home phases. The pilot has also helped inform modifications in clinical monitoring, technological modifications, and logistics planning in preparation for the definitive clinical trial. TRIAL REGISTRATION: Clinical Trials Registry of India, CTRI/2017/09/009789 BioMed Central 2018-05-21 /pmc/articles/PMC5961490/ /pubmed/29796294 http://dx.doi.org/10.1186/s40814-018-0293-5 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Rao, Suman
Thankachan, Prashanth
Amrutur, Bharadwaj
Washington, Maryann
Mony, Prem K.
Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_full Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_fullStr Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_full_unstemmed Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_short Continuous, real-time monitoring of neonatal position and temperature during Kangaroo Mother Care using a wearable sensor: a techno-feasibility pilot study
title_sort continuous, real-time monitoring of neonatal position and temperature during kangaroo mother care using a wearable sensor: a techno-feasibility pilot study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5961490/
https://www.ncbi.nlm.nih.gov/pubmed/29796294
http://dx.doi.org/10.1186/s40814-018-0293-5
work_keys_str_mv AT raosuman continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT thankachanprashanth continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT amruturbharadwaj continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT washingtonmaryann continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy
AT monypremk continuousrealtimemonitoringofneonatalpositionandtemperatureduringkangaroomothercareusingawearablesensoratechnofeasibilitypilotstudy