Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study

INTRODUCTION: The force applied to the teeth by fixed orthopaedic expanders has previously been studied, but not the force applied to the orthodontic mini-implant (OMI) used to expand the maxilla with Hyrax hybrid expanders (HHE). OBJECTIVE: The aim of this article was to evaluate the clinical safet...

Descripción completa

Detalles Bibliográficos
Autores principales: de la Iglesia, Gonzalo, Walter, André, de la Iglesia, Fernando, Winsauer, Heinz, Puigdollers, Andreu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dental Press International 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5962246/
https://www.ncbi.nlm.nih.gov/pubmed/29791684
http://dx.doi.org/10.1590/2177-6709.23.1.037-045.oar
_version_ 1783324865912111104
author de la Iglesia, Gonzalo
Walter, André
de la Iglesia, Fernando
Winsauer, Heinz
Puigdollers, Andreu
author_facet de la Iglesia, Gonzalo
Walter, André
de la Iglesia, Fernando
Winsauer, Heinz
Puigdollers, Andreu
author_sort de la Iglesia, Gonzalo
collection PubMed
description INTRODUCTION: The force applied to the teeth by fixed orthopaedic expanders has previously been studied, but not the force applied to the orthodontic mini-implant (OMI) used to expand the maxilla with Hyrax hybrid expanders (HHE). OBJECTIVE: The aim of this article was to evaluate the clinical safety of the components (OMI, abutment and double wire arms) of three different force-transmitting systems (FTS) for conducting orthopaedic maxillary expansion: Jeil Medical & Tiger Dental™, Microdent™ and Ortholox™. METHODS: For the realization of this in vitro study of the resistance to mechanical load, three different abutment types (bonded, screwed on, and coupling) and three different OMIs’ diameters (Jeil™ 2.5 mm, Microdent™ 1.6 mm and Ortholox™ 2.2 mm) were used. Ten tests for each of these three FTS were carried out in a static lateral load in artificial bone blocks (Sawbones™) by a Galdabini universal testing machine, then comparing its performance. Comparisons of loads, deformations and fractures were carried out by means of radiographs of FTS components in each case. RESULTS: At 1- mm load and within the elastic deformation, FTS values ranged from 67 ± 13 N to 183 ± 48 N. Under great deformations, Jeil & Tiger™ was the one who withstood the greatest loads, with an average 378 ± 22 N; followed by Microdent™, with 201 ± 18 N, and Ortholox™, with 103 ± 10 N. At 3 mm load, the OMIs shaft bends and deforms when the diameter is smaller than 2.5 mm. The abutment fixation is crucial to transmit forces and moments. CONCLUSIONS: The present study shows the importance of a rigid design of the different components of HHEs, and also that HHEs would be suitable for maxillary expansion in adolescents and young adults, since its mean expansion forces exceed 120N. Furthermore, early abutment detachment or smaller mini-implants diameter would only be appropriate for children.
format Online
Article
Text
id pubmed-5962246
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dental Press International
record_format MEDLINE/PubMed
spelling pubmed-59622462018-05-24 Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study de la Iglesia, Gonzalo Walter, André de la Iglesia, Fernando Winsauer, Heinz Puigdollers, Andreu Dental Press J Orthod Original Article INTRODUCTION: The force applied to the teeth by fixed orthopaedic expanders has previously been studied, but not the force applied to the orthodontic mini-implant (OMI) used to expand the maxilla with Hyrax hybrid expanders (HHE). OBJECTIVE: The aim of this article was to evaluate the clinical safety of the components (OMI, abutment and double wire arms) of three different force-transmitting systems (FTS) for conducting orthopaedic maxillary expansion: Jeil Medical & Tiger Dental™, Microdent™ and Ortholox™. METHODS: For the realization of this in vitro study of the resistance to mechanical load, three different abutment types (bonded, screwed on, and coupling) and three different OMIs’ diameters (Jeil™ 2.5 mm, Microdent™ 1.6 mm and Ortholox™ 2.2 mm) were used. Ten tests for each of these three FTS were carried out in a static lateral load in artificial bone blocks (Sawbones™) by a Galdabini universal testing machine, then comparing its performance. Comparisons of loads, deformations and fractures were carried out by means of radiographs of FTS components in each case. RESULTS: At 1- mm load and within the elastic deformation, FTS values ranged from 67 ± 13 N to 183 ± 48 N. Under great deformations, Jeil & Tiger™ was the one who withstood the greatest loads, with an average 378 ± 22 N; followed by Microdent™, with 201 ± 18 N, and Ortholox™, with 103 ± 10 N. At 3 mm load, the OMIs shaft bends and deforms when the diameter is smaller than 2.5 mm. The abutment fixation is crucial to transmit forces and moments. CONCLUSIONS: The present study shows the importance of a rigid design of the different components of HHEs, and also that HHEs would be suitable for maxillary expansion in adolescents and young adults, since its mean expansion forces exceed 120N. Furthermore, early abutment detachment or smaller mini-implants diameter would only be appropriate for children. Dental Press International 2018 /pmc/articles/PMC5962246/ /pubmed/29791684 http://dx.doi.org/10.1590/2177-6709.23.1.037-045.oar Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License
spellingShingle Original Article
de la Iglesia, Gonzalo
Walter, André
de la Iglesia, Fernando
Winsauer, Heinz
Puigdollers, Andreu
Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title_full Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title_fullStr Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title_full_unstemmed Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title_short Stability of the anterior arm of three different Hyrax hybrid expanders: an in vitro study
title_sort stability of the anterior arm of three different hyrax hybrid expanders: an in vitro study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5962246/
https://www.ncbi.nlm.nih.gov/pubmed/29791684
http://dx.doi.org/10.1590/2177-6709.23.1.037-045.oar
work_keys_str_mv AT delaiglesiagonzalo stabilityoftheanteriorarmofthreedifferenthyraxhybridexpandersaninvitrostudy
AT walterandre stabilityoftheanteriorarmofthreedifferenthyraxhybridexpandersaninvitrostudy
AT delaiglesiafernando stabilityoftheanteriorarmofthreedifferenthyraxhybridexpandersaninvitrostudy
AT winsauerheinz stabilityoftheanteriorarmofthreedifferenthyraxhybridexpandersaninvitrostudy
AT puigdollersandreu stabilityoftheanteriorarmofthreedifferenthyraxhybridexpandersaninvitrostudy