Cargando…

Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation

BACKGROUND: Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. The purpose of this study was to compare graft healing in the femoral tunnel, implant-related failure, and clinical resul...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, Jin Hwan, Ko, Taeg Su, Lee, Yong Seuk, Jeong, Hwa Jae, Park, Jong Kuen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Orthopaedic Association 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5964263/
https://www.ncbi.nlm.nih.gov/pubmed/29854338
http://dx.doi.org/10.4055/cios.2018.10.2.157
_version_ 1783325151797968896
author Ahn, Jin Hwan
Ko, Taeg Su
Lee, Yong Seuk
Jeong, Hwa Jae
Park, Jong Kuen
author_facet Ahn, Jin Hwan
Ko, Taeg Su
Lee, Yong Seuk
Jeong, Hwa Jae
Park, Jong Kuen
author_sort Ahn, Jin Hwan
collection PubMed
description BACKGROUND: Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. The purpose of this study was to compare graft healing in the femoral tunnel, implant-related failure, and clinical results between fixed- and adjustable-length loop devices in outside-in ACL reconstruction. METHODS: A total of 109 patients who underwent ACL reconstruction using the outside-in technique from December 2010 to July 2014 were included. For femoral graft fixation, a fixed-length loop device was used in 48 patients (fixed-loop group) and an adjustable-length loop device was used in 61 patients (adjustable-loop group). For evaluation of graft healing in the femoral tunnel, magnetic resonance imaging was performed at postoperative 6 months and the signal-to-noise ratios (SNRs) of the tendon graft and tendon-bone interface in the femoral bone tunnel were evaluated. The presence of synovial fluid was evaluated to determine loop lengthening at the femoral tunnel exit. Clinical results assessed using International Knee Documentation Committee score, Tegner-Lysholm Knee Scoring scale, and knee instability tests were compared between groups. RESULTS: The SNRs of the tendon graft and tendon-bone interface were not statistically different between groups. The presence of synovial fluid at the femoral exit showed no statistical difference between groups. Clinical results were not significantly different between groups. CONCLUSIONS: The adjustable-length loop device provided comparable graft healing, implant-related failure, and clinical results with the fixed-length loop device, allowing adaptation of the graft to the different tunnel lengths. Therefore, it could be effectively used with an adjustment according to the femoral tunnel length.
format Online
Article
Text
id pubmed-5964263
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Orthopaedic Association
record_format MEDLINE/PubMed
spelling pubmed-59642632018-06-01 Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation Ahn, Jin Hwan Ko, Taeg Su Lee, Yong Seuk Jeong, Hwa Jae Park, Jong Kuen Clin Orthop Surg Original Article BACKGROUND: Cortical suspensory femoral fixation is commonly performed for graft fixation to the femur in anterior cruciate ligament (ACL) reconstruction using hamstring tendons. The purpose of this study was to compare graft healing in the femoral tunnel, implant-related failure, and clinical results between fixed- and adjustable-length loop devices in outside-in ACL reconstruction. METHODS: A total of 109 patients who underwent ACL reconstruction using the outside-in technique from December 2010 to July 2014 were included. For femoral graft fixation, a fixed-length loop device was used in 48 patients (fixed-loop group) and an adjustable-length loop device was used in 61 patients (adjustable-loop group). For evaluation of graft healing in the femoral tunnel, magnetic resonance imaging was performed at postoperative 6 months and the signal-to-noise ratios (SNRs) of the tendon graft and tendon-bone interface in the femoral bone tunnel were evaluated. The presence of synovial fluid was evaluated to determine loop lengthening at the femoral tunnel exit. Clinical results assessed using International Knee Documentation Committee score, Tegner-Lysholm Knee Scoring scale, and knee instability tests were compared between groups. RESULTS: The SNRs of the tendon graft and tendon-bone interface were not statistically different between groups. The presence of synovial fluid at the femoral exit showed no statistical difference between groups. Clinical results were not significantly different between groups. CONCLUSIONS: The adjustable-length loop device provided comparable graft healing, implant-related failure, and clinical results with the fixed-length loop device, allowing adaptation of the graft to the different tunnel lengths. Therefore, it could be effectively used with an adjustment according to the femoral tunnel length. The Korean Orthopaedic Association 2018-06 2018-05-18 /pmc/articles/PMC5964263/ /pubmed/29854338 http://dx.doi.org/10.4055/cios.2018.10.2.157 Text en Copyright © 2018 by The Korean Orthopaedic Association http://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Ahn, Jin Hwan
Ko, Taeg Su
Lee, Yong Seuk
Jeong, Hwa Jae
Park, Jong Kuen
Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title_full Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title_fullStr Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title_full_unstemmed Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title_short Magnetic Resonance Imaging and Clinical Results of Outside-in Anterior Cruciate Ligament Reconstruction: A Comparison of Fixed- and Adjustable-Length Loop Cortical Fixation
title_sort magnetic resonance imaging and clinical results of outside-in anterior cruciate ligament reconstruction: a comparison of fixed- and adjustable-length loop cortical fixation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5964263/
https://www.ncbi.nlm.nih.gov/pubmed/29854338
http://dx.doi.org/10.4055/cios.2018.10.2.157
work_keys_str_mv AT ahnjinhwan magneticresonanceimagingandclinicalresultsofoutsideinanteriorcruciateligamentreconstructionacomparisonoffixedandadjustablelengthloopcorticalfixation
AT kotaegsu magneticresonanceimagingandclinicalresultsofoutsideinanteriorcruciateligamentreconstructionacomparisonoffixedandadjustablelengthloopcorticalfixation
AT leeyongseuk magneticresonanceimagingandclinicalresultsofoutsideinanteriorcruciateligamentreconstructionacomparisonoffixedandadjustablelengthloopcorticalfixation
AT jeonghwajae magneticresonanceimagingandclinicalresultsofoutsideinanteriorcruciateligamentreconstructionacomparisonoffixedandadjustablelengthloopcorticalfixation
AT parkjongkuen magneticresonanceimagingandclinicalresultsofoutsideinanteriorcruciateligamentreconstructionacomparisonoffixedandadjustablelengthloopcorticalfixation