Cargando…

Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy

PURPOSE: High tibial osteotomy (HTO) has been adopted as an effective surgery for medial degeneration of the osteoarthritis (OA) knee. However, satisfactory outcomes necessitate the precise creation and distraction of osteotomized wedges and the use of intraoperative X-ray images to continually moni...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Jesse Chieh-Szu, Chen, Cheng-Fong, Luo, Chu-An, Chang, Ming-Chau, Lee, Oscar K., Huang, Ye, Lin, Shang-Chih
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5964591/
https://www.ncbi.nlm.nih.gov/pubmed/29854810
http://dx.doi.org/10.1155/2018/9246529
_version_ 1783325208514396160
author Yang, Jesse Chieh-Szu
Chen, Cheng-Fong
Luo, Chu-An
Chang, Ming-Chau
Lee, Oscar K.
Huang, Ye
Lin, Shang-Chih
author_facet Yang, Jesse Chieh-Szu
Chen, Cheng-Fong
Luo, Chu-An
Chang, Ming-Chau
Lee, Oscar K.
Huang, Ye
Lin, Shang-Chih
author_sort Yang, Jesse Chieh-Szu
collection PubMed
description PURPOSE: High tibial osteotomy (HTO) has been adopted as an effective surgery for medial degeneration of the osteoarthritis (OA) knee. However, satisfactory outcomes necessitate the precise creation and distraction of osteotomized wedges and the use of intraoperative X-ray images to continually monitor the wedge-related manipulation. Thus HTO is highly technique-demanding and has a high radiation exposure. We report a patient-specific instrument (PSI) guide for the precise creation and distraction of HTO wedge. METHODS: This study first parameterized five HTO procedures to serve as a design rationale for an innovative PSI guide. Preoperative X-ray and computed tomography- (CT-) scanning images were used to design and fabricate PSI guides for clinical use. The weight-bearing line (WBL) of the ten patients was shifted to the Fujisawa's point and instrumented using the TomoFix system. The radiological results of the PSI-guided HTO surgery were evaluated by the WBL percentage and tibial slope. RESULTS: All patients consistently showed an increased range of motion and a decrease in pain and discomfort at about three-month follow-up. This study demonstrates the satisfactory accuracy of the WBL adjustment and tibial slope maintenance after HTO with PSI guide. For all patients, the average pre- and postoperative WBL are, respectively, 14.2% and 60.2%, while the tibial slopes are 9.9 and 10.1 degrees. The standard deviations are 2.78 and 0.36, respectively, in postoperative WBL and tibial slope. The relative errors of the pre- and postoperative WBL percentage and tibial slope averaged 4.9% and 4.1%, respectively. CONCLUSION: Instead of using navigator systems, this study integrated 2D and 3D preoperative planning to create a PSI guide that could most likely render the outcomes close to the planning. The PSI guide is a precise procedure that is time-saving, radiation-reducing, and relatively easy to use. Precise osteotomy and good short-term results were achieved with the PSI guide.
format Online
Article
Text
id pubmed-5964591
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-59645912018-05-31 Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy Yang, Jesse Chieh-Szu Chen, Cheng-Fong Luo, Chu-An Chang, Ming-Chau Lee, Oscar K. Huang, Ye Lin, Shang-Chih Biomed Res Int Research Article PURPOSE: High tibial osteotomy (HTO) has been adopted as an effective surgery for medial degeneration of the osteoarthritis (OA) knee. However, satisfactory outcomes necessitate the precise creation and distraction of osteotomized wedges and the use of intraoperative X-ray images to continually monitor the wedge-related manipulation. Thus HTO is highly technique-demanding and has a high radiation exposure. We report a patient-specific instrument (PSI) guide for the precise creation and distraction of HTO wedge. METHODS: This study first parameterized five HTO procedures to serve as a design rationale for an innovative PSI guide. Preoperative X-ray and computed tomography- (CT-) scanning images were used to design and fabricate PSI guides for clinical use. The weight-bearing line (WBL) of the ten patients was shifted to the Fujisawa's point and instrumented using the TomoFix system. The radiological results of the PSI-guided HTO surgery were evaluated by the WBL percentage and tibial slope. RESULTS: All patients consistently showed an increased range of motion and a decrease in pain and discomfort at about three-month follow-up. This study demonstrates the satisfactory accuracy of the WBL adjustment and tibial slope maintenance after HTO with PSI guide. For all patients, the average pre- and postoperative WBL are, respectively, 14.2% and 60.2%, while the tibial slopes are 9.9 and 10.1 degrees. The standard deviations are 2.78 and 0.36, respectively, in postoperative WBL and tibial slope. The relative errors of the pre- and postoperative WBL percentage and tibial slope averaged 4.9% and 4.1%, respectively. CONCLUSION: Instead of using navigator systems, this study integrated 2D and 3D preoperative planning to create a PSI guide that could most likely render the outcomes close to the planning. The PSI guide is a precise procedure that is time-saving, radiation-reducing, and relatively easy to use. Precise osteotomy and good short-term results were achieved with the PSI guide. Hindawi 2018-05-08 /pmc/articles/PMC5964591/ /pubmed/29854810 http://dx.doi.org/10.1155/2018/9246529 Text en Copyright © 2018 Jesse Chieh-Szu Yang et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yang, Jesse Chieh-Szu
Chen, Cheng-Fong
Luo, Chu-An
Chang, Ming-Chau
Lee, Oscar K.
Huang, Ye
Lin, Shang-Chih
Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title_full Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title_fullStr Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title_full_unstemmed Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title_short Clinical Experience Using a 3D-Printed Patient-Specific Instrument for Medial Opening Wedge High Tibial Osteotomy
title_sort clinical experience using a 3d-printed patient-specific instrument for medial opening wedge high tibial osteotomy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5964591/
https://www.ncbi.nlm.nih.gov/pubmed/29854810
http://dx.doi.org/10.1155/2018/9246529
work_keys_str_mv AT yangjessechiehszu clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT chenchengfong clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT luochuan clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT changmingchau clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT leeoscark clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT huangye clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy
AT linshangchih clinicalexperienceusinga3dprintedpatientspecificinstrumentformedialopeningwedgehightibialosteotomy