Cargando…

Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?

PURPOSE: MRI is a mandatory requirement to accurately plan Stereotactic Radiosurgery (SRS) for Vestibular Schwannomas. However, MRI may be distorted due not only to inhomogeneity of the static magnetic field and gradients but also due to susceptibility‐induced effects, which are more prominent at hi...

Descripción completa

Detalles Bibliográficos
Autores principales: Schmidt, M. A., Wells, E. J., Davison, K., Riddell, A. M., Welsh, L., Saran, F.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965671/
https://www.ncbi.nlm.nih.gov/pubmed/28019663
http://dx.doi.org/10.1002/mp.12068
_version_ 1783325368812306432
author Schmidt, M. A.
Wells, E. J.
Davison, K.
Riddell, A. M.
Welsh, L.
Saran, F.
author_facet Schmidt, M. A.
Wells, E. J.
Davison, K.
Riddell, A. M.
Welsh, L.
Saran, F.
author_sort Schmidt, M. A.
collection PubMed
description PURPOSE: MRI is a mandatory requirement to accurately plan Stereotactic Radiosurgery (SRS) for Vestibular Schwannomas. However, MRI may be distorted due not only to inhomogeneity of the static magnetic field and gradients but also due to susceptibility‐induced effects, which are more prominent at higher magnetic fields. We assess geometrical distortions around air spaces and consider MRI protocol requirements for SRS planning at 3 T. METHODS: Hardware‐related distortion and the effect of incorrect shimming were investigated with structured test objects. The magnetic field was mapped over the head on five volunteers to assess susceptibility‐related distortion in the naso‐oro‐pharyngeal cavities (NOPC) and around the internal ear canal (IAC). RESULTS: Hardware‐related geometric displacements were found to be less than 0.45 mm within the head volume, after distortion correction. Shimming errors can lead to displacements of up to 4 mm, but errors of this magnitude are unlikely to arise in practice. Susceptibility‐related field inhomogeneity was under 3.4 ppm, 2.8 ppm, and 2.7 ppm for the head, NOPC region and IAC region, respectively. For the SRS planning protocol (890 Hz/pixel, approximately 1 mm(3) isotropic), susceptibility‐related displacements were less than 0.5 mm (head), and 0.4 mm (IAC and NOPC). Large displacements are possible in MRI examinations undertaken with lower receiver bandwidth values, commonly used in clinical MRI. Higher receiver bandwidth makes the protocol less vulnerable to sub‐optimal shimming. The shimming volume and the CT‐MR co‐registration must be considered jointly. CONCLUSION: Geometric displacements can be kept under 1 mm in the vicinity of air spaces within the head at 3 T with appropriate setting of the receiver bandwidth, correct shimming and employing distortion correction.
format Online
Article
Text
id pubmed-5965671
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59656712018-05-24 Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate? Schmidt, M. A. Wells, E. J. Davison, K. Riddell, A. M. Welsh, L. Saran, F. Med Phys THERAPEUTIC INTERVENTIONS PURPOSE: MRI is a mandatory requirement to accurately plan Stereotactic Radiosurgery (SRS) for Vestibular Schwannomas. However, MRI may be distorted due not only to inhomogeneity of the static magnetic field and gradients but also due to susceptibility‐induced effects, which are more prominent at higher magnetic fields. We assess geometrical distortions around air spaces and consider MRI protocol requirements for SRS planning at 3 T. METHODS: Hardware‐related distortion and the effect of incorrect shimming were investigated with structured test objects. The magnetic field was mapped over the head on five volunteers to assess susceptibility‐related distortion in the naso‐oro‐pharyngeal cavities (NOPC) and around the internal ear canal (IAC). RESULTS: Hardware‐related geometric displacements were found to be less than 0.45 mm within the head volume, after distortion correction. Shimming errors can lead to displacements of up to 4 mm, but errors of this magnitude are unlikely to arise in practice. Susceptibility‐related field inhomogeneity was under 3.4 ppm, 2.8 ppm, and 2.7 ppm for the head, NOPC region and IAC region, respectively. For the SRS planning protocol (890 Hz/pixel, approximately 1 mm(3) isotropic), susceptibility‐related displacements were less than 0.5 mm (head), and 0.4 mm (IAC and NOPC). Large displacements are possible in MRI examinations undertaken with lower receiver bandwidth values, commonly used in clinical MRI. Higher receiver bandwidth makes the protocol less vulnerable to sub‐optimal shimming. The shimming volume and the CT‐MR co‐registration must be considered jointly. CONCLUSION: Geometric displacements can be kept under 1 mm in the vicinity of air spaces within the head at 3 T with appropriate setting of the receiver bandwidth, correct shimming and employing distortion correction. John Wiley and Sons Inc. 2017-02-16 2017-02 /pmc/articles/PMC5965671/ /pubmed/28019663 http://dx.doi.org/10.1002/mp.12068 Text en © 2017 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle THERAPEUTIC INTERVENTIONS
Schmidt, M. A.
Wells, E. J.
Davison, K.
Riddell, A. M.
Welsh, L.
Saran, F.
Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title_full Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title_fullStr Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title_full_unstemmed Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title_short Stereotactic radiosurgery planning of vestibular schwannomas: Is MRI at 3 Tesla geometrically accurate?
title_sort stereotactic radiosurgery planning of vestibular schwannomas: is mri at 3 tesla geometrically accurate?
topic THERAPEUTIC INTERVENTIONS
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965671/
https://www.ncbi.nlm.nih.gov/pubmed/28019663
http://dx.doi.org/10.1002/mp.12068
work_keys_str_mv AT schmidtma stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate
AT wellsej stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate
AT davisonk stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate
AT riddellam stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate
AT welshl stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate
AT saranf stereotacticradiosurgeryplanningofvestibularschwannomasismriat3teslageometricallyaccurate