Cargando…

Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique

In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sirakov, Stanimir S, Sirakov, Alexander, Hristov, Hristo, Raychev, Radoslav
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965769/
https://www.ncbi.nlm.nih.gov/pubmed/29776934
http://dx.doi.org/10.1136/bcr-2017-222703
_version_ 1783325376587497472
author Sirakov, Stanimir S
Sirakov, Alexander
Hristov, Hristo
Raychev, Radoslav
author_facet Sirakov, Stanimir S
Sirakov, Alexander
Hristov, Hristo
Raychev, Radoslav
author_sort Sirakov, Stanimir S
collection PubMed
description In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coil delivery, while maintaining parent vessel patency. This case highlights the unique and safe applicability of two crossed Comaneci devices in a ruptured aneurysm with unfavourable anatomy, ultimately resulting in complete aneurysm obliteration. To our knowledge, this is the first reported case of double Comaneci usage in a wide-neck ruptured aneurysm. This technique can be potentially applied in challenging wide-neck bifurcation aneurysms, particularly when double antiplatelet therapy is of concern.
format Online
Article
Text
id pubmed-5965769
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-59657692018-05-31 Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique Sirakov, Stanimir S Sirakov, Alexander Hristov, Hristo Raychev, Radoslav BMJ Case Rep Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation) In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coil delivery, while maintaining parent vessel patency. This case highlights the unique and safe applicability of two crossed Comaneci devices in a ruptured aneurysm with unfavourable anatomy, ultimately resulting in complete aneurysm obliteration. To our knowledge, this is the first reported case of double Comaneci usage in a wide-neck ruptured aneurysm. This technique can be potentially applied in challenging wide-neck bifurcation aneurysms, particularly when double antiplatelet therapy is of concern. BMJ Publishing Group 2018-05-18 /pmc/articles/PMC5965769/ /pubmed/29776934 http://dx.doi.org/10.1136/bcr-2017-222703 Text en © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation)
Sirakov, Stanimir S
Sirakov, Alexander
Hristov, Hristo
Raychev, Radoslav
Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title_full Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title_fullStr Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title_full_unstemmed Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title_short Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
title_sort coiling of ruptured, wide-necked basilar tip aneurysm using double comaneci technique
topic Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation)
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965769/
https://www.ncbi.nlm.nih.gov/pubmed/29776934
http://dx.doi.org/10.1136/bcr-2017-222703
work_keys_str_mv AT sirakovstanimirs coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique
AT sirakovalexander coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique
AT hristovhristo coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique
AT raychevradoslav coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique