Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique
In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965769/ https://www.ncbi.nlm.nih.gov/pubmed/29776934 http://dx.doi.org/10.1136/bcr-2017-222703 |
_version_ | 1783325376587497472 |
---|---|
author | Sirakov, Stanimir S Sirakov, Alexander Hristov, Hristo Raychev, Radoslav |
author_facet | Sirakov, Stanimir S Sirakov, Alexander Hristov, Hristo Raychev, Radoslav |
author_sort | Sirakov, Stanimir S |
collection | PubMed |
description | In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coil delivery, while maintaining parent vessel patency. This case highlights the unique and safe applicability of two crossed Comaneci devices in a ruptured aneurysm with unfavourable anatomy, ultimately resulting in complete aneurysm obliteration. To our knowledge, this is the first reported case of double Comaneci usage in a wide-neck ruptured aneurysm. This technique can be potentially applied in challenging wide-neck bifurcation aneurysms, particularly when double antiplatelet therapy is of concern. |
format | Online Article Text |
id | pubmed-5965769 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-59657692018-05-31 Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique Sirakov, Stanimir S Sirakov, Alexander Hristov, Hristo Raychev, Radoslav BMJ Case Rep Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation) In this report, we present a novel technique of successful coil embolisation using temporary deployment of two Comaneci devices placed in Y configuration across a wide-neck ruptured basilar tip aneurysm. The placement of two devices across the wide aneurysm neck allowed optimal coverage for safe coil delivery, while maintaining parent vessel patency. This case highlights the unique and safe applicability of two crossed Comaneci devices in a ruptured aneurysm with unfavourable anatomy, ultimately resulting in complete aneurysm obliteration. To our knowledge, this is the first reported case of double Comaneci usage in a wide-neck ruptured aneurysm. This technique can be potentially applied in challenging wide-neck bifurcation aneurysms, particularly when double antiplatelet therapy is of concern. BMJ Publishing Group 2018-05-18 /pmc/articles/PMC5965769/ /pubmed/29776934 http://dx.doi.org/10.1136/bcr-2017-222703 Text en © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation) Sirakov, Stanimir S Sirakov, Alexander Hristov, Hristo Raychev, Radoslav Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title | Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title_full | Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title_fullStr | Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title_full_unstemmed | Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title_short | Coiling of ruptured, wide-necked basilar tip aneurysm using double Comaneci technique |
title_sort | coiling of ruptured, wide-necked basilar tip aneurysm using double comaneci technique |
topic | Novel Treatment (New Drug/Intervention; Established Drug/Procedure in New Situation) |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5965769/ https://www.ncbi.nlm.nih.gov/pubmed/29776934 http://dx.doi.org/10.1136/bcr-2017-222703 |
work_keys_str_mv | AT sirakovstanimirs coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique AT sirakovalexander coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique AT hristovhristo coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique AT raychevradoslav coilingofrupturedwideneckedbasilartipaneurysmusingdoublecomanecitechnique |