Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring

BACKGROUND: Reliability cannot be achieved in a clinical laboratory through the control of accuracy in the analytical phase of the testing process alone. Indeed a "mistake" can be defined as any defect occuring during the testing process. In the analysis of clinical specimens, there are ma...

Descripción completa

Detalles Bibliográficos
Autor principal: Wiwanitkit, Viroj
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2001
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC59663/
https://www.ncbi.nlm.nih.gov/pubmed/11696253
http://dx.doi.org/10.1186/1472-6890-1-5
_version_ 1782120097236647936
author Wiwanitkit, Viroj
author_facet Wiwanitkit, Viroj
author_sort Wiwanitkit, Viroj
collection PubMed
description BACKGROUND: Reliability cannot be achieved in a clinical laboratory through the control of accuracy in the analytical phase of the testing process alone. Indeed a "mistake" can be defined as any defect occuring during the testing process. In the analysis of clinical specimens, there are many possible preanalytical sources of error. Therefore, the application of quality system to laboratory testing requires total quality management throughout the laboratory process, including the preanalytical and postanalytical phases. ISO 9002:1994 is a model for quality assurance in production, installation, and servicing, which includes a number of clauses providing guidance for implementation in clinical laboratories. Our laboratory at King Chulalongkorn Memorial Hospital, the largest Thai Red Cross Society hospital, is the first clinical laboratory in Thailand with ISO 9002:1994 certified for the whole unit. METHOD: In this study, we evaluated the frequency and types of preanalytical mistakes found in our laboratory, by monitoring specimens requested for laboratory analyses from both in-patient and out-patient divisions for 6 months. RESULT: Among a total of 935,896 specimens for 941,902 analyses, 1,048 findings were confirmed as preanalytical mistakes; this was a relative frequency of 0.11 % (1,048/935,896). A total of 1,240 mistakes were identified during the study period. Comparing the preanalytical mistakes to other mistakes in the laboratory process monitored in the same setting and period, the distribution of mistakes was: preanalytical 84.52 % (1,048 mistakes), analytical 4.35 % (54 mistakes), and postanalytical 11.13 % (138 mistakes). Of 1,048 preanalytical mistakes, 998 (95.2%) originated in the care units. All preanalytical mistakes, except for 12 (1.15 %) relating to the laboratory barcode reading machine, were due to human error. CONCLUSION: Most mistakes occurred before samples were analysed, either during sampling or preparation for analysis. This suggests that co-operation with clinicians and personnel outside the laboratory is still the key to improvement of laboratory quality.
format Text
id pubmed-59663
institution National Center for Biotechnology Information
language English
publishDate 2001
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-596632001-11-06 Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring Wiwanitkit, Viroj BMC Clin Pathol Research Article BACKGROUND: Reliability cannot be achieved in a clinical laboratory through the control of accuracy in the analytical phase of the testing process alone. Indeed a "mistake" can be defined as any defect occuring during the testing process. In the analysis of clinical specimens, there are many possible preanalytical sources of error. Therefore, the application of quality system to laboratory testing requires total quality management throughout the laboratory process, including the preanalytical and postanalytical phases. ISO 9002:1994 is a model for quality assurance in production, installation, and servicing, which includes a number of clauses providing guidance for implementation in clinical laboratories. Our laboratory at King Chulalongkorn Memorial Hospital, the largest Thai Red Cross Society hospital, is the first clinical laboratory in Thailand with ISO 9002:1994 certified for the whole unit. METHOD: In this study, we evaluated the frequency and types of preanalytical mistakes found in our laboratory, by monitoring specimens requested for laboratory analyses from both in-patient and out-patient divisions for 6 months. RESULT: Among a total of 935,896 specimens for 941,902 analyses, 1,048 findings were confirmed as preanalytical mistakes; this was a relative frequency of 0.11 % (1,048/935,896). A total of 1,240 mistakes were identified during the study period. Comparing the preanalytical mistakes to other mistakes in the laboratory process monitored in the same setting and period, the distribution of mistakes was: preanalytical 84.52 % (1,048 mistakes), analytical 4.35 % (54 mistakes), and postanalytical 11.13 % (138 mistakes). Of 1,048 preanalytical mistakes, 998 (95.2%) originated in the care units. All preanalytical mistakes, except for 12 (1.15 %) relating to the laboratory barcode reading machine, were due to human error. CONCLUSION: Most mistakes occurred before samples were analysed, either during sampling or preparation for analysis. This suggests that co-operation with clinicians and personnel outside the laboratory is still the key to improvement of laboratory quality. BioMed Central 2001-10-16 /pmc/articles/PMC59663/ /pubmed/11696253 http://dx.doi.org/10.1186/1472-6890-1-5 Text en Copyright © 2001 Wiwanitkit; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
Wiwanitkit, Viroj
Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title_full Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title_fullStr Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title_full_unstemmed Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title_short Types and frequency of preanalytical mistakes in the first Thai ISO 9002:1994 certified clinical laboratory, a 6 – month monitoring
title_sort types and frequency of preanalytical mistakes in the first thai iso 9002:1994 certified clinical laboratory, a 6 – month monitoring
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC59663/
https://www.ncbi.nlm.nih.gov/pubmed/11696253
http://dx.doi.org/10.1186/1472-6890-1-5
work_keys_str_mv AT wiwanitkitviroj typesandfrequencyofpreanalyticalmistakesinthefirstthaiiso90021994certifiedclinicallaboratorya6monthmonitoring