Cargando…

Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases

PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Schoenmakers, Daphne A. L., Schotanus, Martijn G. M., Boonen, Bert, Kort, Nanne P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966470/
https://www.ncbi.nlm.nih.gov/pubmed/29147744
http://dx.doi.org/10.1007/s00167-017-4800-7
_version_ 1783325465143934976
author Schoenmakers, Daphne A. L.
Schotanus, Martijn G. M.
Boonen, Bert
Kort, Nanne P.
author_facet Schoenmakers, Daphne A. L.
Schotanus, Martijn G. M.
Boonen, Bert
Kort, Nanne P.
author_sort Schoenmakers, Daphne A. L.
collection PubMed
description PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed using PSI. MATERIALS AND METHODS: A total of 184 consecutive patients (200 TKA) were evaluated. Outcome measures included implant survival rate, adverse events, and the following patient-reported outcome measures (PROMs); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Pain Visual Analogue Score (VAS) and EuroQol-5D Score (EQ-5D). RESULTS: Revision surgery was performed for late secondary prosthetic joint infection (n = 1, total revision), aseptic loosening (n = 1, tibial component revision), instability (n = 1, isolated polyethylene insert exchange), and polyethylene insert breakage (n = 1, isolated polyethylene insert exchange). Other adverse events were as follows: debridement, antibiotics and implant retention for early prosthetic joint infection (n = 1), surgical debridement for haemarthrosis (n = 1), superficial wound infection (n = 2), thromboembolic events (n = 2), compartment syndrome (n = 1), and nerve injury (n = 2). All median outcome scores for patient reported outcome measures at 5 years improved significantly compared with the preoperative values (p ≤ 0.05). Median outcome scores were not significantly different between 1- and 5-year moments of follow-up, except for a significant decrease of EQ-VAS (p ≤ 0.05) between these two follow-up moments. CONCLUSION: PROMs are consistent for 5-year follow-up of TKA using PSI. After 5 years of follow-up, revision surgery for any reason occurred in four patients (2%). LEVEL OF EVIDENCE: III.
format Online
Article
Text
id pubmed-5966470
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-59664702018-06-04 Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases Schoenmakers, Daphne A. L. Schotanus, Martijn G. M. Boonen, Bert Kort, Nanne P. Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed using PSI. MATERIALS AND METHODS: A total of 184 consecutive patients (200 TKA) were evaluated. Outcome measures included implant survival rate, adverse events, and the following patient-reported outcome measures (PROMs); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Pain Visual Analogue Score (VAS) and EuroQol-5D Score (EQ-5D). RESULTS: Revision surgery was performed for late secondary prosthetic joint infection (n = 1, total revision), aseptic loosening (n = 1, tibial component revision), instability (n = 1, isolated polyethylene insert exchange), and polyethylene insert breakage (n = 1, isolated polyethylene insert exchange). Other adverse events were as follows: debridement, antibiotics and implant retention for early prosthetic joint infection (n = 1), surgical debridement for haemarthrosis (n = 1), superficial wound infection (n = 2), thromboembolic events (n = 2), compartment syndrome (n = 1), and nerve injury (n = 2). All median outcome scores for patient reported outcome measures at 5 years improved significantly compared with the preoperative values (p ≤ 0.05). Median outcome scores were not significantly different between 1- and 5-year moments of follow-up, except for a significant decrease of EQ-VAS (p ≤ 0.05) between these two follow-up moments. CONCLUSION: PROMs are consistent for 5-year follow-up of TKA using PSI. After 5 years of follow-up, revision surgery for any reason occurred in four patients (2%). LEVEL OF EVIDENCE: III. Springer Berlin Heidelberg 2017-11-17 2018 /pmc/articles/PMC5966470/ /pubmed/29147744 http://dx.doi.org/10.1007/s00167-017-4800-7 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Knee
Schoenmakers, Daphne A. L.
Schotanus, Martijn G. M.
Boonen, Bert
Kort, Nanne P.
Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title_full Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title_fullStr Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title_full_unstemmed Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title_short Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
title_sort consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
topic Knee
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966470/
https://www.ncbi.nlm.nih.gov/pubmed/29147744
http://dx.doi.org/10.1007/s00167-017-4800-7
work_keys_str_mv AT schoenmakersdaphneal consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases
AT schotanusmartijngm consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases
AT boonenbert consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases
AT kortnannep consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases