Cargando…
Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases
PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed usin...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966470/ https://www.ncbi.nlm.nih.gov/pubmed/29147744 http://dx.doi.org/10.1007/s00167-017-4800-7 |
_version_ | 1783325465143934976 |
---|---|
author | Schoenmakers, Daphne A. L. Schotanus, Martijn G. M. Boonen, Bert Kort, Nanne P. |
author_facet | Schoenmakers, Daphne A. L. Schotanus, Martijn G. M. Boonen, Bert Kort, Nanne P. |
author_sort | Schoenmakers, Daphne A. L. |
collection | PubMed |
description | PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed using PSI. MATERIALS AND METHODS: A total of 184 consecutive patients (200 TKA) were evaluated. Outcome measures included implant survival rate, adverse events, and the following patient-reported outcome measures (PROMs); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Pain Visual Analogue Score (VAS) and EuroQol-5D Score (EQ-5D). RESULTS: Revision surgery was performed for late secondary prosthetic joint infection (n = 1, total revision), aseptic loosening (n = 1, tibial component revision), instability (n = 1, isolated polyethylene insert exchange), and polyethylene insert breakage (n = 1, isolated polyethylene insert exchange). Other adverse events were as follows: debridement, antibiotics and implant retention for early prosthetic joint infection (n = 1), surgical debridement for haemarthrosis (n = 1), superficial wound infection (n = 2), thromboembolic events (n = 2), compartment syndrome (n = 1), and nerve injury (n = 2). All median outcome scores for patient reported outcome measures at 5 years improved significantly compared with the preoperative values (p ≤ 0.05). Median outcome scores were not significantly different between 1- and 5-year moments of follow-up, except for a significant decrease of EQ-VAS (p ≤ 0.05) between these two follow-up moments. CONCLUSION: PROMs are consistent for 5-year follow-up of TKA using PSI. After 5 years of follow-up, revision surgery for any reason occurred in four patients (2%). LEVEL OF EVIDENCE: III. |
format | Online Article Text |
id | pubmed-5966470 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-59664702018-06-04 Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases Schoenmakers, Daphne A. L. Schotanus, Martijn G. M. Boonen, Bert Kort, Nanne P. Knee Surg Sports Traumatol Arthrosc Knee PURPOSE: The purpose of this study was to evaluate the 5-year follow-up results of the first 200 total knee arthroplasties (TKA) performed by one high-volume surgeon, using patient-specific information (PSI). To date, there has been no other research into the mid-term follow-up of TKA performed using PSI. MATERIALS AND METHODS: A total of 184 consecutive patients (200 TKA) were evaluated. Outcome measures included implant survival rate, adverse events, and the following patient-reported outcome measures (PROMs); Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), Pain Visual Analogue Score (VAS) and EuroQol-5D Score (EQ-5D). RESULTS: Revision surgery was performed for late secondary prosthetic joint infection (n = 1, total revision), aseptic loosening (n = 1, tibial component revision), instability (n = 1, isolated polyethylene insert exchange), and polyethylene insert breakage (n = 1, isolated polyethylene insert exchange). Other adverse events were as follows: debridement, antibiotics and implant retention for early prosthetic joint infection (n = 1), surgical debridement for haemarthrosis (n = 1), superficial wound infection (n = 2), thromboembolic events (n = 2), compartment syndrome (n = 1), and nerve injury (n = 2). All median outcome scores for patient reported outcome measures at 5 years improved significantly compared with the preoperative values (p ≤ 0.05). Median outcome scores were not significantly different between 1- and 5-year moments of follow-up, except for a significant decrease of EQ-VAS (p ≤ 0.05) between these two follow-up moments. CONCLUSION: PROMs are consistent for 5-year follow-up of TKA using PSI. After 5 years of follow-up, revision surgery for any reason occurred in four patients (2%). LEVEL OF EVIDENCE: III. Springer Berlin Heidelberg 2017-11-17 2018 /pmc/articles/PMC5966470/ /pubmed/29147744 http://dx.doi.org/10.1007/s00167-017-4800-7 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Knee Schoenmakers, Daphne A. L. Schotanus, Martijn G. M. Boonen, Bert Kort, Nanne P. Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title | Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title_full | Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title_fullStr | Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title_full_unstemmed | Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title_short | Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
title_sort | consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases |
topic | Knee |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966470/ https://www.ncbi.nlm.nih.gov/pubmed/29147744 http://dx.doi.org/10.1007/s00167-017-4800-7 |
work_keys_str_mv | AT schoenmakersdaphneal consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases AT schotanusmartijngm consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases AT boonenbert consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases AT kortnannep consistencyinpatientreportedoutcomemeasuresaftertotalkneearthroplastyusingpatientspecificinstrumentationa5yearfollowupof200consecutivecases |