Cargando…

The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure

BACKGROUND: The thoracic fluid content (TFC) and its percent change compared to the baseline (TFCd0%) derived from a bioreactance technique using a noninvasive cardiac output monitoring (NICOM) device correlate well with the amount of fluid removal in patients undergoing hemodialysis and with intrao...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoon, Tae-Gyoon, Jang, Kyunghwan, Oh, Chung-Sik, Kim, Seong-Hyop, Kang, Woon-Seok
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966686/
https://www.ncbi.nlm.nih.gov/pubmed/29854747
http://dx.doi.org/10.1155/2018/3635708
_version_ 1783325505612677120
author Yoon, Tae-Gyoon
Jang, Kyunghwan
Oh, Chung-Sik
Kim, Seong-Hyop
Kang, Woon-Seok
author_facet Yoon, Tae-Gyoon
Jang, Kyunghwan
Oh, Chung-Sik
Kim, Seong-Hyop
Kang, Woon-Seok
author_sort Yoon, Tae-Gyoon
collection PubMed
description BACKGROUND: The thoracic fluid content (TFC) and its percent change compared to the baseline (TFCd0%) derived from a bioreactance technique using a noninvasive cardiac output monitoring (NICOM) device correlate well with the amount of fluid removal in patients undergoing hemodialysis and with intraoperative fluid balance in pediatric patients undergoing cardiac surgery. We hypothesized that TFC or TFCd0% would also be a useful indicator allowing fluid management in pediatric patients undergoing a Fontan procedure. METHODS: The medical records of patients who underwent an elective Fontan procedure were reviewed retrospectively. The intraoperative variables recorded at two time points were used in the analysis: when the NICOM data obtained just after anesthesia induction (T0) and just before transfer of the patient from the operating room to the ICU (T1). The analyzed variables were hemodynamic parameters, TFC, TFCd0%, stroke volume variation, body weight gain, change in the central venous pressure, and difference in the TFC (ΔTFC). RESULTS: The correlation coefficient between TFCd0% and body weight gain was 0.546 (p = 0.01); between TFCd0% and body weight gain% 0.572 (p = 0.007); and between TFCd0% and intraoperative fluid balance 0.554 (p = 0.009). The coefficient of determination derived from a linear regression analysis of TFCd0% versus body weight gain was 0.30 (p = 0.01); between TFCd0% and body weight gain% 0.33 (p = 0.007); and between TFCd0% and intraoperative fluid balance 0.31 (p = 0.009). CONCLUSIONS: TFCd0% correlated well with body weight gain, body weight gain%, and intraoperative fluid balance. It is a useful indicator in the intraoperative fluid management of pediatric patients undergoing a Fontan procedure. TRIAL REGISTRATION: This trial is registered with Clinical Research Information Service KCT0002062.
format Online
Article
Text
id pubmed-5966686
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-59666862018-05-31 The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure Yoon, Tae-Gyoon Jang, Kyunghwan Oh, Chung-Sik Kim, Seong-Hyop Kang, Woon-Seok Biomed Res Int Research Article BACKGROUND: The thoracic fluid content (TFC) and its percent change compared to the baseline (TFCd0%) derived from a bioreactance technique using a noninvasive cardiac output monitoring (NICOM) device correlate well with the amount of fluid removal in patients undergoing hemodialysis and with intraoperative fluid balance in pediatric patients undergoing cardiac surgery. We hypothesized that TFC or TFCd0% would also be a useful indicator allowing fluid management in pediatric patients undergoing a Fontan procedure. METHODS: The medical records of patients who underwent an elective Fontan procedure were reviewed retrospectively. The intraoperative variables recorded at two time points were used in the analysis: when the NICOM data obtained just after anesthesia induction (T0) and just before transfer of the patient from the operating room to the ICU (T1). The analyzed variables were hemodynamic parameters, TFC, TFCd0%, stroke volume variation, body weight gain, change in the central venous pressure, and difference in the TFC (ΔTFC). RESULTS: The correlation coefficient between TFCd0% and body weight gain was 0.546 (p = 0.01); between TFCd0% and body weight gain% 0.572 (p = 0.007); and between TFCd0% and intraoperative fluid balance 0.554 (p = 0.009). The coefficient of determination derived from a linear regression analysis of TFCd0% versus body weight gain was 0.30 (p = 0.01); between TFCd0% and body weight gain% 0.33 (p = 0.007); and between TFCd0% and intraoperative fluid balance 0.31 (p = 0.009). CONCLUSIONS: TFCd0% correlated well with body weight gain, body weight gain%, and intraoperative fluid balance. It is a useful indicator in the intraoperative fluid management of pediatric patients undergoing a Fontan procedure. TRIAL REGISTRATION: This trial is registered with Clinical Research Information Service KCT0002062. Hindawi 2018-05-09 /pmc/articles/PMC5966686/ /pubmed/29854747 http://dx.doi.org/10.1155/2018/3635708 Text en Copyright © 2018 Tae-Gyoon Yoon et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Yoon, Tae-Gyoon
Jang, Kyunghwan
Oh, Chung-Sik
Kim, Seong-Hyop
Kang, Woon-Seok
The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title_full The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title_fullStr The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title_full_unstemmed The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title_short The Correlation between the Change in Thoracic Fluid Content and the Change in Patient Body Weight in Fontan Procedure
title_sort correlation between the change in thoracic fluid content and the change in patient body weight in fontan procedure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5966686/
https://www.ncbi.nlm.nih.gov/pubmed/29854747
http://dx.doi.org/10.1155/2018/3635708
work_keys_str_mv AT yoontaegyoon thecorrelationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT jangkyunghwan thecorrelationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT ohchungsik thecorrelationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT kimseonghyop thecorrelationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT kangwoonseok thecorrelationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT yoontaegyoon correlationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT jangkyunghwan correlationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT ohchungsik correlationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT kimseonghyop correlationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure
AT kangwoonseok correlationbetweenthechangeinthoracicfluidcontentandthechangeinpatientbodyweightinfontanprocedure