Cargando…

Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T

It has been shown that density‐weighted (DW) k‐space sampling with spiral and conventional phase encoding trajectories reduces spatial side lobes in magnetic resonance spectroscopic imaging (MRSI). In this study, we propose a new concentric ring trajectory (CRT) for DW‐MRSI that samples k‐space with...

Descripción completa

Detalles Bibliográficos
Autores principales: Chiew, Mark, Jiang, Wenwen, Burns, Brian, Larson, Peder, Steel, Adam, Jezzard, Peter, Albert Thomas, M., Emir, Uzay E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969060/
https://www.ncbi.nlm.nih.gov/pubmed/29044762
http://dx.doi.org/10.1002/nbm.3838
_version_ 1783325900073336832
author Chiew, Mark
Jiang, Wenwen
Burns, Brian
Larson, Peder
Steel, Adam
Jezzard, Peter
Albert Thomas, M.
Emir, Uzay E.
author_facet Chiew, Mark
Jiang, Wenwen
Burns, Brian
Larson, Peder
Steel, Adam
Jezzard, Peter
Albert Thomas, M.
Emir, Uzay E.
author_sort Chiew, Mark
collection PubMed
description It has been shown that density‐weighted (DW) k‐space sampling with spiral and conventional phase encoding trajectories reduces spatial side lobes in magnetic resonance spectroscopic imaging (MRSI). In this study, we propose a new concentric ring trajectory (CRT) for DW‐MRSI that samples k‐space with a density that is proportional to a spatial, isotropic Hanning window. The properties of two different DW‐CRTs were compared against a radially equidistant (RE) CRT and an echo‐planar spectroscopic imaging (EPSI) trajectory in simulations, phantoms and in vivo experiments. These experiments, conducted at 7 T with a fixed nominal voxel size and matched acquisition times, revealed that the two DW‐CRT designs improved the shape of the spatial response function by suppressing side lobes, also resulting in improved signal‐to‐noise ratio (SNR). High‐quality spectra were acquired for all trajectories from a specific region of interest in the motor cortex with an in‐plane resolution of 7.5 × 7.5 mm(2) in 8 min 3 s. Due to hardware limitations, high‐spatial‐resolution spectra with an in‐plane resolution of 5 × 5 mm(2) and an acquisition time of 12 min 48 s were acquired only for the RE and one of the DW‐CRT trajectories and not for EPSI. For all phantom and in vivo experiments, DW‐CRTs resulted in the highest SNR. The achieved in vivo spectral quality of the DW‐CRT method allowed for reliable metabolic mapping of eight metabolites including N‐acetylaspartylglutamate, γ‐aminobutyric acid and glutathione with Cramér‐Rao lower bounds below 50%, using an LCModel analysis. Finally, high‐quality metabolic mapping of a whole brain slice using DW‐CRT was achieved with a high in‐plane resolution of 5 × 5 mm(2) in a healthy subject. These findings demonstrate that our DW‐CRT MRSI technique can perform robustly on MRI systems and within a clinically feasible acquisition time.
format Online
Article
Text
id pubmed-5969060
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59690602018-05-30 Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T Chiew, Mark Jiang, Wenwen Burns, Brian Larson, Peder Steel, Adam Jezzard, Peter Albert Thomas, M. Emir, Uzay E. NMR Biomed Research Articles It has been shown that density‐weighted (DW) k‐space sampling with spiral and conventional phase encoding trajectories reduces spatial side lobes in magnetic resonance spectroscopic imaging (MRSI). In this study, we propose a new concentric ring trajectory (CRT) for DW‐MRSI that samples k‐space with a density that is proportional to a spatial, isotropic Hanning window. The properties of two different DW‐CRTs were compared against a radially equidistant (RE) CRT and an echo‐planar spectroscopic imaging (EPSI) trajectory in simulations, phantoms and in vivo experiments. These experiments, conducted at 7 T with a fixed nominal voxel size and matched acquisition times, revealed that the two DW‐CRT designs improved the shape of the spatial response function by suppressing side lobes, also resulting in improved signal‐to‐noise ratio (SNR). High‐quality spectra were acquired for all trajectories from a specific region of interest in the motor cortex with an in‐plane resolution of 7.5 × 7.5 mm(2) in 8 min 3 s. Due to hardware limitations, high‐spatial‐resolution spectra with an in‐plane resolution of 5 × 5 mm(2) and an acquisition time of 12 min 48 s were acquired only for the RE and one of the DW‐CRT trajectories and not for EPSI. For all phantom and in vivo experiments, DW‐CRTs resulted in the highest SNR. The achieved in vivo spectral quality of the DW‐CRT method allowed for reliable metabolic mapping of eight metabolites including N‐acetylaspartylglutamate, γ‐aminobutyric acid and glutathione with Cramér‐Rao lower bounds below 50%, using an LCModel analysis. Finally, high‐quality metabolic mapping of a whole brain slice using DW‐CRT was achieved with a high in‐plane resolution of 5 × 5 mm(2) in a healthy subject. These findings demonstrate that our DW‐CRT MRSI technique can perform robustly on MRI systems and within a clinically feasible acquisition time. John Wiley and Sons Inc. 2017-10-18 2018-01 /pmc/articles/PMC5969060/ /pubmed/29044762 http://dx.doi.org/10.1002/nbm.3838 Text en © 2017 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Chiew, Mark
Jiang, Wenwen
Burns, Brian
Larson, Peder
Steel, Adam
Jezzard, Peter
Albert Thomas, M.
Emir, Uzay E.
Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title_full Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title_fullStr Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title_full_unstemmed Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title_short Density‐weighted concentric rings k‐space trajectory for (1)H magnetic resonance spectroscopic imaging at 7 T
title_sort density‐weighted concentric rings k‐space trajectory for (1)h magnetic resonance spectroscopic imaging at 7 t
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969060/
https://www.ncbi.nlm.nih.gov/pubmed/29044762
http://dx.doi.org/10.1002/nbm.3838
work_keys_str_mv AT chiewmark densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT jiangwenwen densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT burnsbrian densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT larsonpeder densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT steeladam densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT jezzardpeter densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT albertthomasm densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t
AT emiruzaye densityweightedconcentricringskspacetrajectoryfor1hmagneticresonancespectroscopicimagingat7t