PURPOSE: The feasibility of magnetic resonance image (MRI)‐based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Padilla‐Cabal, Fatima, Georg, Dietmar, Fuchs, Hermann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969113/
https://www.ncbi.nlm.nih.gov/pubmed/29532490
http://dx.doi.org/10.1002/mp.12854
_version_ 1783325908971552768
author Padilla‐Cabal, Fatima
Georg, Dietmar
Fuchs, Hermann
author_facet Padilla‐Cabal, Fatima
Georg, Dietmar
Fuchs, Hermann
author_sort Padilla‐Cabal, Fatima
collection PubMed
description PURPOSE: The feasibility of magnetic resonance image (MRI)‐based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field regions of up to 3 T. METHODS: Monte Carlo (MC) simulations using the GATE 7.1/GEANT4.9.4p02 toolkit were performed to generate calibration and benchmarking data for the PBA. Dose distributions from proton beams in the clinical required energy range 60–250 MeV impinging on a 400 × 400 × 400 mm(3) water phantom and transverse magnetic fields ranging from 0 to 3 T were considered. Energy depositions in homogeneous and heterogeneous phantoms filled with water, adipose, bone, and air were evaluated for proton energies of 80, 150, and 240 MeV, combining a trajectory calculation method and look‐up tables (LUT). A novel parametrization model, using independent tailed Gauss fitting functions, was employed to describe the nonsymmetric shape of lateral beam profiles. Integrated depth‐dose curves (IDD), lateral dose profiles, and two‐dimensional dose distributions calculated with the PBA were compared with results from MC simulations to assess the performance of the algorithm. A gamma index criterion of 2%/2 mm was used for analysis. RESULTS: A close to perfect agreement was observed for PB‐based dose calculations in water in magnetic fields of 0.5, 1.5, and 3 T. IDD functions showed differences between the PBA and MC of less than 0.1% before the Bragg peak, and deviations of 2–8% in the distal energy falloff region. Gamma index pass rates higher than 99% and mean values lower than 0.1 were encountered for all analyzed configurations. For homogeneous phantoms, only the full bone configuration offered deviations in the Bragg peak position of up to 1.7% and overestimations of the lateral beam spot width for high‐energy protons and magnetic field intensities. An excellent agreement between PBA and MC dose calculation was also achieved using slab‐like and lateral heterogeneous phantoms, with gamma index passing rates above 98% and mean values between 0.1 and 0.2. As expected, agreement reduced for high‐energy protons and high‐intensity magnetic fields, although results remained good enough to be considered for future implementation in clinical practice. CONCLUSIONS: The proposed pencil beam algorithm for protons can accurately account for dose distortion effects induced by external magnetic fields. The application of an analytical model for dose estimation and corrections reduces the calculation times considerably, making the presented PBA a suitable candidate for integration in a treatment planning system.
format Online
Article
Text
id pubmed-5969113
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59691132018-05-30 A pencil beam algorithm for magnetic resonance image‐guided proton therapy Padilla‐Cabal, Fatima Georg, Dietmar Fuchs, Hermann Med Phys EMERGING IMAGING AND THERAPY MODALITIES PURPOSE: The feasibility of magnetic resonance image (MRI)‐based proton therapy is based, among several other factors, on the implementation of appropriate extensions on current dose calculation methods. This work aims to develop a pencil beam algorithm (PBA) for dose calculation of proton beams within magnetic field regions of up to 3 T. METHODS: Monte Carlo (MC) simulations using the GATE 7.1/GEANT4.9.4p02 toolkit were performed to generate calibration and benchmarking data for the PBA. Dose distributions from proton beams in the clinical required energy range 60–250 MeV impinging on a 400 × 400 × 400 mm(3) water phantom and transverse magnetic fields ranging from 0 to 3 T were considered. Energy depositions in homogeneous and heterogeneous phantoms filled with water, adipose, bone, and air were evaluated for proton energies of 80, 150, and 240 MeV, combining a trajectory calculation method and look‐up tables (LUT). A novel parametrization model, using independent tailed Gauss fitting functions, was employed to describe the nonsymmetric shape of lateral beam profiles. Integrated depth‐dose curves (IDD), lateral dose profiles, and two‐dimensional dose distributions calculated with the PBA were compared with results from MC simulations to assess the performance of the algorithm. A gamma index criterion of 2%/2 mm was used for analysis. RESULTS: A close to perfect agreement was observed for PB‐based dose calculations in water in magnetic fields of 0.5, 1.5, and 3 T. IDD functions showed differences between the PBA and MC of less than 0.1% before the Bragg peak, and deviations of 2–8% in the distal energy falloff region. Gamma index pass rates higher than 99% and mean values lower than 0.1 were encountered for all analyzed configurations. For homogeneous phantoms, only the full bone configuration offered deviations in the Bragg peak position of up to 1.7% and overestimations of the lateral beam spot width for high‐energy protons and magnetic field intensities. An excellent agreement between PBA and MC dose calculation was also achieved using slab‐like and lateral heterogeneous phantoms, with gamma index passing rates above 98% and mean values between 0.1 and 0.2. As expected, agreement reduced for high‐energy protons and high‐intensity magnetic fields, although results remained good enough to be considered for future implementation in clinical practice. CONCLUSIONS: The proposed pencil beam algorithm for protons can accurately account for dose distortion effects induced by external magnetic fields. The application of an analytical model for dose estimation and corrections reduces the calculation times considerably, making the presented PBA a suitable candidate for integration in a treatment planning system. John Wiley and Sons Inc. 2018-03-30 2018-05 /pmc/articles/PMC5969113/ /pubmed/29532490 http://dx.doi.org/10.1002/mp.12854 Text en © 2018 The Authors. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle EMERGING IMAGING AND THERAPY MODALITIES
Padilla‐Cabal, Fatima
Georg, Dietmar
Fuchs, Hermann
A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title_full A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title_fullStr A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title_full_unstemmed A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title_short A pencil beam algorithm for magnetic resonance image‐guided proton therapy
title_sort pencil beam algorithm for magnetic resonance image‐guided proton therapy
topic EMERGING IMAGING AND THERAPY MODALITIES
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969113/
https://www.ncbi.nlm.nih.gov/pubmed/29532490
http://dx.doi.org/10.1002/mp.12854
work_keys_str_mv AT padillacabalfatima apencilbeamalgorithmformagneticresonanceimageguidedprotontherapy
AT georgdietmar apencilbeamalgorithmformagneticresonanceimageguidedprotontherapy
AT fuchshermann apencilbeamalgorithmformagneticresonanceimageguidedprotontherapy
AT padillacabalfatima pencilbeamalgorithmformagneticresonanceimageguidedprotontherapy
AT georgdietmar pencilbeamalgorithmformagneticresonanceimageguidedprotontherapy
AT fuchshermann pencilbeamalgorithmformagneticresonanceimageguidedprotontherapy