Cargando…

Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor

This study aims to assess non-contact respiration measurement during the exercise stress test using an upright bicycle ergometer and to evaluate the ventilation threshold value. We propose the tracking of the chest and abdomen by applying the motion capture function of the Kinect V2 sensor to cope w...

Descripción completa

Detalles Bibliográficos
Autores principales: Aoki, Hirooki, Nakamura, Hidetoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969190/
https://www.ncbi.nlm.nih.gov/pubmed/29910327
http://dx.doi.org/10.3390/sports6010023
_version_ 1783325922549563392
author Aoki, Hirooki
Nakamura, Hidetoshi
author_facet Aoki, Hirooki
Nakamura, Hidetoshi
author_sort Aoki, Hirooki
collection PubMed
description This study aims to assess non-contact respiration measurement during the exercise stress test using an upright bicycle ergometer and to evaluate the ventilation threshold value. We propose the tracking of the chest and abdomen by applying the motion capture function of the Kinect V2 sensor to cope with an increase in physical exercise accompanied by an increase in exercise intensity. In the proposed method, the region enclosed by the four joints corresponding to the left and right shoulders and the right and left hip extracted using the Kinect sensor is set as the region of interest. The region is updated in response to changes in body movements. By extracting the signal of the pedaling frequency component from the time series data of the volume in the region, only the volume change due to respiration was extracted. The point at which the increased rate of the volume change elevates is estimated as the ventilation threshold. The assessment of the efficacy of the proposed method by comparative analysis using an expiration gas analyzer confirmed that non-contact respiration evaluation is possible with an exercise intensity of about 160 W. Furthermore, the ventilation threshold estimated by the proposed method is ±10 W of the estimated value by expiratory gas analyzer.
format Online
Article
Text
id pubmed-5969190
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-59691902018-06-13 Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor Aoki, Hirooki Nakamura, Hidetoshi Sports (Basel) Article This study aims to assess non-contact respiration measurement during the exercise stress test using an upright bicycle ergometer and to evaluate the ventilation threshold value. We propose the tracking of the chest and abdomen by applying the motion capture function of the Kinect V2 sensor to cope with an increase in physical exercise accompanied by an increase in exercise intensity. In the proposed method, the region enclosed by the four joints corresponding to the left and right shoulders and the right and left hip extracted using the Kinect sensor is set as the region of interest. The region is updated in response to changes in body movements. By extracting the signal of the pedaling frequency component from the time series data of the volume in the region, only the volume change due to respiration was extracted. The point at which the increased rate of the volume change elevates is estimated as the ventilation threshold. The assessment of the efficacy of the proposed method by comparative analysis using an expiration gas analyzer confirmed that non-contact respiration evaluation is possible with an exercise intensity of about 160 W. Furthermore, the ventilation threshold estimated by the proposed method is ±10 W of the estimated value by expiratory gas analyzer. MDPI 2018-03-13 /pmc/articles/PMC5969190/ /pubmed/29910327 http://dx.doi.org/10.3390/sports6010023 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Aoki, Hirooki
Nakamura, Hidetoshi
Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title_full Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title_fullStr Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title_full_unstemmed Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title_short Non-Contact Respiration Measurement during Exercise Tolerance Test by Using Kinect Sensor
title_sort non-contact respiration measurement during exercise tolerance test by using kinect sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5969190/
https://www.ncbi.nlm.nih.gov/pubmed/29910327
http://dx.doi.org/10.3390/sports6010023
work_keys_str_mv AT aokihirooki noncontactrespirationmeasurementduringexercisetolerancetestbyusingkinectsensor
AT nakamurahidetoshi noncontactrespirationmeasurementduringexercisetolerancetestbyusingkinectsensor