Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation

BACKGROUND: The present study was performed with the aim of comparing the peak inspiratory pressure and lung dynamic compliance between a classic laryngeal mask airway (LMA) and an endotracheal tube in children under mechanical ventilation. MATERIALS AND METHODS: In this study, 30 children aged 1 to...

Descripción completa

Detalles Bibliográficos
Autores principales: Mahdavi, Alireza, Razavi, Seyed Sajad, Malekianzadeh, Bita, Sadeghi, Afsaneh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: National Research Institute of Tuberculosis and Lung Disease 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5971760/
https://www.ncbi.nlm.nih.gov/pubmed/29849686
_version_ 1783326325768978432
author Mahdavi, Alireza
Razavi, Seyed Sajad
Malekianzadeh, Bita
Sadeghi, Afsaneh
author_facet Mahdavi, Alireza
Razavi, Seyed Sajad
Malekianzadeh, Bita
Sadeghi, Afsaneh
author_sort Mahdavi, Alireza
collection PubMed
description BACKGROUND: The present study was performed with the aim of comparing the peak inspiratory pressure and lung dynamic compliance between a classic laryngeal mask airway (LMA) and an endotracheal tube in children under mechanical ventilation. MATERIALS AND METHODS: In this study, 30 children aged 1 to 7 years with a physical condition of ASA I–II who were admitted for operations to repair inguinal hernias, hydroceles, or hypospadias were randomly enrolled. After induction of anesthesia, the appropriate laryngeal mask was used for each patient and they were placed under pressure-controlled mechanical ventilation. The peak inspiratory pressure was adjusted and recorded to obtain an appropriate tidal volume, then the laryngeal mask was removed and the appropriate size uncuffed endotracheal tube was inserted and the patient was placed again under controlled mechanical ventilation. The required settings were adjusted and peak inspiratory pressure and tidal volume were measured and recorded by the ventilator. Dynamic compliance was also calculated in both cases using the appropriate formula. RESULTS: The results showed that peak inspiratory pressure (PIP) with the use of LMA in children under mechanical ventilation was less than the PIP with the use of an endotracheal tube (p<0.05). Also, the pulmonary dynamic compliance with a laryngeal mask was greater than the use of an endotracheal tube (p<0.05). CONCLUSION: A laryngeal mask airway due to its low airway resistance and high dynamic compliance is an acceptable alternative to a tracheal tube during mechanical ventilation and it can be a good alternative to the endotracheal tube, especially during mechanical ventilation of children, in whom avoidance of barotrauma is desirable.
format Online
Article
Text
id pubmed-5971760
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher National Research Institute of Tuberculosis and Lung Disease
record_format MEDLINE/PubMed
spelling pubmed-59717602018-05-30 Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation Mahdavi, Alireza Razavi, Seyed Sajad Malekianzadeh, Bita Sadeghi, Afsaneh Tanaffos Original Article BACKGROUND: The present study was performed with the aim of comparing the peak inspiratory pressure and lung dynamic compliance between a classic laryngeal mask airway (LMA) and an endotracheal tube in children under mechanical ventilation. MATERIALS AND METHODS: In this study, 30 children aged 1 to 7 years with a physical condition of ASA I–II who were admitted for operations to repair inguinal hernias, hydroceles, or hypospadias were randomly enrolled. After induction of anesthesia, the appropriate laryngeal mask was used for each patient and they were placed under pressure-controlled mechanical ventilation. The peak inspiratory pressure was adjusted and recorded to obtain an appropriate tidal volume, then the laryngeal mask was removed and the appropriate size uncuffed endotracheal tube was inserted and the patient was placed again under controlled mechanical ventilation. The required settings were adjusted and peak inspiratory pressure and tidal volume were measured and recorded by the ventilator. Dynamic compliance was also calculated in both cases using the appropriate formula. RESULTS: The results showed that peak inspiratory pressure (PIP) with the use of LMA in children under mechanical ventilation was less than the PIP with the use of an endotracheal tube (p<0.05). Also, the pulmonary dynamic compliance with a laryngeal mask was greater than the use of an endotracheal tube (p<0.05). CONCLUSION: A laryngeal mask airway due to its low airway resistance and high dynamic compliance is an acceptable alternative to a tracheal tube during mechanical ventilation and it can be a good alternative to the endotracheal tube, especially during mechanical ventilation of children, in whom avoidance of barotrauma is desirable. National Research Institute of Tuberculosis and Lung Disease 2017-06 /pmc/articles/PMC5971760/ /pubmed/29849686 Text en Copyright© 2017 National Research Institute of Tuberculosis and Lung Disease http://creativecommons.org/licenses/by/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Mahdavi, Alireza
Razavi, Seyed Sajad
Malekianzadeh, Bita
Sadeghi, Afsaneh
Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title_full Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title_fullStr Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title_full_unstemmed Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title_short Comparison of the Peak Inspiratory Pressure and Lung Dynamic Compliance between a Classic Laryngeal Mask Airway and an Endotracheal Tube in Children Under Mechanical Ventilation
title_sort comparison of the peak inspiratory pressure and lung dynamic compliance between a classic laryngeal mask airway and an endotracheal tube in children under mechanical ventilation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5971760/
https://www.ncbi.nlm.nih.gov/pubmed/29849686
work_keys_str_mv AT mahdavialireza comparisonofthepeakinspiratorypressureandlungdynamiccompliancebetweenaclassiclaryngealmaskairwayandanendotrachealtubeinchildrenundermechanicalventilation
AT razaviseyedsajad comparisonofthepeakinspiratorypressureandlungdynamiccompliancebetweenaclassiclaryngealmaskairwayandanendotrachealtubeinchildrenundermechanicalventilation
AT malekianzadehbita comparisonofthepeakinspiratorypressureandlungdynamiccompliancebetweenaclassiclaryngealmaskairwayandanendotrachealtubeinchildrenundermechanicalventilation
AT sadeghiafsaneh comparisonofthepeakinspiratorypressureandlungdynamiccompliancebetweenaclassiclaryngealmaskairwayandanendotrachealtubeinchildrenundermechanicalventilation