Cargando…

Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report

INTRODUCTION: While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of re...

Descripción completa

Detalles Bibliográficos
Autores principales: Vincent, John, Alshaygy, Ibrahim, Muir, Jeffrey M, Kuzyk, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5974678/
https://www.ncbi.nlm.nih.gov/pubmed/29854694
http://dx.doi.org/10.13107/jocr.2250-0685.996
_version_ 1783326863537471488
author Vincent, John
Alshaygy, Ibrahim
Muir, Jeffrey M
Kuzyk, Paul
author_facet Vincent, John
Alshaygy, Ibrahim
Muir, Jeffrey M
Kuzyk, Paul
author_sort Vincent, John
collection PubMed
description INTRODUCTION: While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. CASE REPORT: An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. CONCLUSIONS: In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery.
format Online
Article
Text
id pubmed-5974678
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-59746782018-05-31 Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report Vincent, John Alshaygy, Ibrahim Muir, Jeffrey M Kuzyk, Paul J Orthop Case Rep Case Report INTRODUCTION: While intraoperative navigation systems have been shown to improve outcomes in primary total hip arthroplasty (THA), their use in the context of revision has been largely overlooked. This case report presents the first documented use of an imageless navigation tool in the context of revision THA, and an unexpected benefit to the surgical procedure as a result. CASE REPORT: An 84-year-old female patient presented following five episodes of dislocation of the left hip and with pain in the left buttock, groin, and posterior aspect of her hip. Relevant surgical history included primary hip arthroplasty in 1999 and the first revision in 2014. Preoperative analysis revealed a constrained liner that had become disengaged and migrated inferiorly, lodging at the distal aspect of the femoral neck. Acetabular protrusion was also noted. The pre-operative plan included the replacement of the fragmented liner and likely of the acetabular cup due to hardware failure. Intraoperative assessment, however, revealed that the cup was in good condition and would be difficult to remove due to substantial bony ingrowth. With the assistance of imageless navigation, the orientation of the acetabular cup was determined and a new constrained liner was cemented into the preexisting acetabular component at an altered orientation, correcting anteversion by 7°. CONCLUSIONS: In revision hip arthroplasty cases, image-based navigation is limited by the presence of existing implants and corresponding metal artefact. This case demonstrates the successful use of an imageless navigation tool for revision surgery. Use of navigation led to the unexpected intraoperative discovery that the acetabular cup was in an acceptable state, and allowed the surgical team to correct the position of the cup using a constrained liner, thus preserving the cup. This significantly benefitted patient outcome, due to the risks associated with the removal of a firmly fixated acetabular cup. While more extensive research is required, this case demonstrates that imageless navigation may be an indispensable tool for revision surgery. Indian Orthopaedic Research Group 2018 /pmc/articles/PMC5974678/ /pubmed/29854694 http://dx.doi.org/10.13107/jocr.2250-0685.996 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Vincent, John
Alshaygy, Ibrahim
Muir, Jeffrey M
Kuzyk, Paul
Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title_full Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title_fullStr Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title_full_unstemmed Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title_short Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report
title_sort preservation of the acetabular cup during revision total hip arthroplasty using a novel mini-navigation tool: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5974678/
https://www.ncbi.nlm.nih.gov/pubmed/29854694
http://dx.doi.org/10.13107/jocr.2250-0685.996
work_keys_str_mv AT vincentjohn preservationoftheacetabularcupduringrevisiontotalhiparthroplastyusinganovelmininavigationtoolacasereport
AT alshaygyibrahim preservationoftheacetabularcupduringrevisiontotalhiparthroplastyusinganovelmininavigationtoolacasereport
AT muirjeffreym preservationoftheacetabularcupduringrevisiontotalhiparthroplastyusinganovelmininavigationtoolacasereport
AT kuzykpaul preservationoftheacetabularcupduringrevisiontotalhiparthroplastyusinganovelmininavigationtoolacasereport