Cargando…
3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+)
We developed an asymmetric fluorescent sensor 1 for Cu(2+), based on 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY), by introducing 4-carboxyphenyl and bis(pyridin-2-ylmethyl)amine groups at the 5- and 3-positions, respectively, of the BODIPY core. We then investigated the photophysical and cat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978191/ https://www.ncbi.nlm.nih.gov/pubmed/29772719 http://dx.doi.org/10.3390/ma11050814 |
_version_ | 1783327488867303424 |
---|---|
author | Hafuka, Akira Satoh, Hisashi Yamada, Koji Takahashi, Masahiro Okabe, Satoshi |
author_facet | Hafuka, Akira Satoh, Hisashi Yamada, Koji Takahashi, Masahiro Okabe, Satoshi |
author_sort | Hafuka, Akira |
collection | PubMed |
description | We developed an asymmetric fluorescent sensor 1 for Cu(2+), based on 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY), by introducing 4-carboxyphenyl and bis(pyridin-2-ylmethyl)amine groups at the 5- and 3-positions, respectively, of the BODIPY core. We then investigated the photophysical and cation-sensing properties of the sensor. BODIPY 1 showed large absorption and fluorescence spectral shifts on binding to Cu(2+). The fluorescence peak at 580 nm red-shifted to 620 nm. The binding stoichiometry of BODIPY 1 and Cu(2+) was 1:3. The ratio of the fluorescence intensity at 620 nm to that at 580 nm (F(620)/F(580)) increased with increasing concentration of Cu(2+) (3–10 equiv); this enabled ratiometric determination of Cu(2+). Although BODIPY 1 showed good selectivity for Cu(2+), there was an interfering effect of Fe(3+). BODIPY 1 could be used for the naked-eye detection of Cu(2+) in a water-containing sample. |
format | Online Article Text |
id | pubmed-5978191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-59781912018-05-31 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) Hafuka, Akira Satoh, Hisashi Yamada, Koji Takahashi, Masahiro Okabe, Satoshi Materials (Basel) Article We developed an asymmetric fluorescent sensor 1 for Cu(2+), based on 4,4-difluoro-4-bora-3a,4a-diaza-s-indacene (BODIPY), by introducing 4-carboxyphenyl and bis(pyridin-2-ylmethyl)amine groups at the 5- and 3-positions, respectively, of the BODIPY core. We then investigated the photophysical and cation-sensing properties of the sensor. BODIPY 1 showed large absorption and fluorescence spectral shifts on binding to Cu(2+). The fluorescence peak at 580 nm red-shifted to 620 nm. The binding stoichiometry of BODIPY 1 and Cu(2+) was 1:3. The ratio of the fluorescence intensity at 620 nm to that at 580 nm (F(620)/F(580)) increased with increasing concentration of Cu(2+) (3–10 equiv); this enabled ratiometric determination of Cu(2+). Although BODIPY 1 showed good selectivity for Cu(2+), there was an interfering effect of Fe(3+). BODIPY 1 could be used for the naked-eye detection of Cu(2+) in a water-containing sample. MDPI 2018-05-16 /pmc/articles/PMC5978191/ /pubmed/29772719 http://dx.doi.org/10.3390/ma11050814 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Hafuka, Akira Satoh, Hisashi Yamada, Koji Takahashi, Masahiro Okabe, Satoshi 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title | 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title_full | 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title_fullStr | 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title_full_unstemmed | 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title_short | 3-[Bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-BODIPY as Ratiometric Fluorescent Sensor for Cu(2+) |
title_sort | 3-[bis(pyridin-2-ylmethyl)amino]-5-(4-carboxyphenyl)-bodipy as ratiometric fluorescent sensor for cu(2+) |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978191/ https://www.ncbi.nlm.nih.gov/pubmed/29772719 http://dx.doi.org/10.3390/ma11050814 |
work_keys_str_mv | AT hafukaakira 3bispyridin2ylmethylamino54carboxyphenylbodipyasratiometricfluorescentsensorforcu2 AT satohhisashi 3bispyridin2ylmethylamino54carboxyphenylbodipyasratiometricfluorescentsensorforcu2 AT yamadakoji 3bispyridin2ylmethylamino54carboxyphenylbodipyasratiometricfluorescentsensorforcu2 AT takahashimasahiro 3bispyridin2ylmethylamino54carboxyphenylbodipyasratiometricfluorescentsensorforcu2 AT okabesatoshi 3bispyridin2ylmethylamino54carboxyphenylbodipyasratiometricfluorescentsensorforcu2 |