Cargando…

Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique

PURPOSE: The addition of a braided bio‐absorbable vicryl coating to the surface of radioactive seeds used for low dose rate (LDR) prostate brachytherapy is intended to reduce the incidence of seed movement and migration. Here, we present a single‐institution study of the frequency and severity of se...

Descripción completa

Detalles Bibliográficos
Autores principales: Warrell, Gregory R., Xing, Yan, Podder, Tarun K., Traughber, Bryan J., Ellis, Rodney J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978941/
https://www.ncbi.nlm.nih.gov/pubmed/29667307
http://dx.doi.org/10.1002/acm2.12254
_version_ 1783327588531306496
author Warrell, Gregory R.
Xing, Yan
Podder, Tarun K.
Traughber, Bryan J.
Ellis, Rodney J.
author_facet Warrell, Gregory R.
Xing, Yan
Podder, Tarun K.
Traughber, Bryan J.
Ellis, Rodney J.
author_sort Warrell, Gregory R.
collection PubMed
description PURPOSE: The addition of a braided bio‐absorbable vicryl coating to the surface of radioactive seeds used for low dose rate (LDR) prostate brachytherapy is intended to reduce the incidence of seed movement and migration. Here, we present a single‐institution study of the frequency and severity of seed slippage (initial seed movement) of coated seeds in comparison with uncoated seeds. METHODS: Forty‐seven patients received permanent prostate brachytherapy, with either coated (n = 26) or uncoated (n = 21) seeds. AgX100 (125)I seeds, coated or uncoated, and uncoated Model 200 (103)Pd seeds were used. During the ultrasound‐guided implantation procedure, each implanted seed was categorized as having remained in the implanted position after being placed, having moved slightly, or having left the ultrasound field of view. RESULTS: 3.1% of the coated seeds (AgX100 seeds, n = 70) and 6.9% of the uncoated seeds (AgX100 and Model 200 seeds, n = 128) were observed to have moved at least 2 mm from their initial implant positions, respectively. The difference in incidence of this movement was 54.4% (P = 0.0026). Coated AgX100 seeds demonstrated a 66.7% lower rate of movement of at least 2 mm than that for uncoated AgX100 seeds (P = 0.038), and a 49.0% lower rate than that for Model 200 seeds (P = 0.021). While no significant differences were noted in prescription dose coverage of the prostate or the studied dosimetric parameters for the organs at risk between the coated and uncoated seeds (P > 0.05) in the CT‐based Day‐0 postoperative plans, the limited sample size and differences in energies between the (125)I and (103)Pd seeds make further analysis of postoperative dosimetric coverage difficult without additional data directly comparing the coated and uncoated (125)I seeds. CONCLUSION: When the vicryl coating is used, seeds have a significantly lower propensity to slip from their initial implant locations. This may help maintain dosimetric integrity, warranting further study of postoperative dosimetry.
format Online
Article
Text
id pubmed-5978941
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59789412018-06-01 Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique Warrell, Gregory R. Xing, Yan Podder, Tarun K. Traughber, Bryan J. Ellis, Rodney J. J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: The addition of a braided bio‐absorbable vicryl coating to the surface of radioactive seeds used for low dose rate (LDR) prostate brachytherapy is intended to reduce the incidence of seed movement and migration. Here, we present a single‐institution study of the frequency and severity of seed slippage (initial seed movement) of coated seeds in comparison with uncoated seeds. METHODS: Forty‐seven patients received permanent prostate brachytherapy, with either coated (n = 26) or uncoated (n = 21) seeds. AgX100 (125)I seeds, coated or uncoated, and uncoated Model 200 (103)Pd seeds were used. During the ultrasound‐guided implantation procedure, each implanted seed was categorized as having remained in the implanted position after being placed, having moved slightly, or having left the ultrasound field of view. RESULTS: 3.1% of the coated seeds (AgX100 seeds, n = 70) and 6.9% of the uncoated seeds (AgX100 and Model 200 seeds, n = 128) were observed to have moved at least 2 mm from their initial implant positions, respectively. The difference in incidence of this movement was 54.4% (P = 0.0026). Coated AgX100 seeds demonstrated a 66.7% lower rate of movement of at least 2 mm than that for uncoated AgX100 seeds (P = 0.038), and a 49.0% lower rate than that for Model 200 seeds (P = 0.021). While no significant differences were noted in prescription dose coverage of the prostate or the studied dosimetric parameters for the organs at risk between the coated and uncoated seeds (P > 0.05) in the CT‐based Day‐0 postoperative plans, the limited sample size and differences in energies between the (125)I and (103)Pd seeds make further analysis of postoperative dosimetric coverage difficult without additional data directly comparing the coated and uncoated (125)I seeds. CONCLUSION: When the vicryl coating is used, seeds have a significantly lower propensity to slip from their initial implant locations. This may help maintain dosimetric integrity, warranting further study of postoperative dosimetry. John Wiley and Sons Inc. 2018-04-17 /pmc/articles/PMC5978941/ /pubmed/29667307 http://dx.doi.org/10.1002/acm2.12254 Text en © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Warrell, Gregory R.
Xing, Yan
Podder, Tarun K.
Traughber, Bryan J.
Ellis, Rodney J.
Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title_full Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title_fullStr Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title_full_unstemmed Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title_short Reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
title_sort reduction of seed motion using a bio‐absorbable polymer coating during permanent prostate brachytherapy using a mick applicator technique
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5978941/
https://www.ncbi.nlm.nih.gov/pubmed/29667307
http://dx.doi.org/10.1002/acm2.12254
work_keys_str_mv AT warrellgregoryr reductionofseedmotionusingabioabsorbablepolymercoatingduringpermanentprostatebrachytherapyusingamickapplicatortechnique
AT xingyan reductionofseedmotionusingabioabsorbablepolymercoatingduringpermanentprostatebrachytherapyusingamickapplicatortechnique
AT poddertarunk reductionofseedmotionusingabioabsorbablepolymercoatingduringpermanentprostatebrachytherapyusingamickapplicatortechnique
AT traughberbryanj reductionofseedmotionusingabioabsorbablepolymercoatingduringpermanentprostatebrachytherapyusingamickapplicatortechnique
AT ellisrodneyj reductionofseedmotionusingabioabsorbablepolymercoatingduringpermanentprostatebrachytherapyusingamickapplicatortechnique