Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion

Despite the multitude of stents implanted annually worldwide, the most common complication called in‐stent restenosis still poses a significant risk to patients. Here, a “smart” stent equipped with microscale sensors and wireless interface is developed to enable continuous monitoring of restenosis t...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Xing, Assadsangabi, Babak, Hsiang, York, Takahata, Kenichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5979749/
https://www.ncbi.nlm.nih.gov/pubmed/29876203
http://dx.doi.org/10.1002/advs.201700560
_version_ 1783327760315318272
author Chen, Xing
Assadsangabi, Babak
Hsiang, York
Takahata, Kenichi
author_facet Chen, Xing
Assadsangabi, Babak
Hsiang, York
Takahata, Kenichi
author_sort Chen, Xing
collection PubMed
description Despite the multitude of stents implanted annually worldwide, the most common complication called in‐stent restenosis still poses a significant risk to patients. Here, a “smart” stent equipped with microscale sensors and wireless interface is developed to enable continuous monitoring of restenosis through the implanted stent. This electrically active stent functions as a radiofrequency wireless pressure transducer to track local hemodynamic changes upon a renarrowing condition. The smart stent is devised and constructed to fulfill both engineering and clinical requirements while proving its compatibility with the standard angioplasty procedure. Prototypes pass testing through assembly on balloon catheters withstanding crimping forces of >100 N and balloon expansion pressure up to 16 atm, and show wireless sensing with a resolution of 12.4 mmHg. In a swine model, this device demonstrates wireless detection of blood clot formation, as well as real‐time tracking of local blood pressure change over a range of 108 mmHg that well covers the range involved in human. The demonstrated results are expected to greatly advance smart stent technology toward its clinical practice.
format Online
Article
Text
id pubmed-5979749
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59797492018-06-06 Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion Chen, Xing Assadsangabi, Babak Hsiang, York Takahata, Kenichi Adv Sci (Weinh) Full Papers Despite the multitude of stents implanted annually worldwide, the most common complication called in‐stent restenosis still poses a significant risk to patients. Here, a “smart” stent equipped with microscale sensors and wireless interface is developed to enable continuous monitoring of restenosis through the implanted stent. This electrically active stent functions as a radiofrequency wireless pressure transducer to track local hemodynamic changes upon a renarrowing condition. The smart stent is devised and constructed to fulfill both engineering and clinical requirements while proving its compatibility with the standard angioplasty procedure. Prototypes pass testing through assembly on balloon catheters withstanding crimping forces of >100 N and balloon expansion pressure up to 16 atm, and show wireless sensing with a resolution of 12.4 mmHg. In a swine model, this device demonstrates wireless detection of blood clot formation, as well as real‐time tracking of local blood pressure change over a range of 108 mmHg that well covers the range involved in human. The demonstrated results are expected to greatly advance smart stent technology toward its clinical practice. John Wiley and Sons Inc. 2018-02-16 /pmc/articles/PMC5979749/ /pubmed/29876203 http://dx.doi.org/10.1002/advs.201700560 Text en © 2017 The Authors. Published by WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Papers
Chen, Xing
Assadsangabi, Babak
Hsiang, York
Takahata, Kenichi
Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title_full Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title_fullStr Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title_full_unstemmed Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title_short Enabling Angioplasty‐Ready “Smart” Stents to Detect In‐Stent Restenosis and Occlusion
title_sort enabling angioplasty‐ready “smart” stents to detect in‐stent restenosis and occlusion
topic Full Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5979749/
https://www.ncbi.nlm.nih.gov/pubmed/29876203
http://dx.doi.org/10.1002/advs.201700560
work_keys_str_mv AT chenxing enablingangioplastyreadysmartstentstodetectinstentrestenosisandocclusion
AT assadsangabibabak enablingangioplastyreadysmartstentstodetectinstentrestenosisandocclusion
AT hsiangyork enablingangioplastyreadysmartstentstodetectinstentrestenosisandocclusion
AT takahatakenichi enablingangioplastyreadysmartstentstodetectinstentrestenosisandocclusion