Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs

BACKGROUND: Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine. OBJECTIVE: To compare angiographic measurements using two commonly employed reference calibration...

Descripción completa

Detalles Bibliográficos
Autores principales: Markovic, Lauren E., Scansen, Brian A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980279/
https://www.ncbi.nlm.nih.gov/pubmed/29528135
http://dx.doi.org/10.1111/jvim.15082
_version_ 1783327858872025088
author Markovic, Lauren E.
Scansen, Brian A.
author_facet Markovic, Lauren E.
Scansen, Brian A.
author_sort Markovic, Lauren E.
collection PubMed
description BACKGROUND: Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine. OBJECTIVE: To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR). ANIMALS: Thirty‐five client‐owned dogs undergoing transcatheter intervention. METHODS: Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired t‐test, the method of Bland and Altman, and Passing‐Bablok regression. RESULTS: A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (P < .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, P = .0003). CONCLUSIONS AND CLINICAL IMPORTANCE: Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs.
format Online
Article
Text
id pubmed-5980279
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-59802792018-06-06 Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs Markovic, Lauren E. Scansen, Brian A. J Vet Intern Med SMALL ANIMAL BACKGROUND: Different methods to perform reference calibration of an angiographic image exist; however, a prospective comparison of calibration methods has yet to be investigated in veterinary medicine. OBJECTIVE: To compare angiographic measurements using two commonly employed reference calibration methods, an esophageal pigtail marker catheter (EC) versus a radiopaque table ruler (TR). ANIMALS: Thirty‐five client‐owned dogs undergoing transcatheter intervention. METHODS: Prospective comparison study. Two reference calibration methods, EC and TR, were recorded in dogs undergoing transcatheter procedures from May 2016 to July 2017. Relevant measurements were performed in triplicate and averaged after image calibration to either EC or TR. Comparisons between methods were made by correlation, paired t‐test, the method of Bland and Altman, and Passing‐Bablok regression. RESULTS: A total of 39 angiographic structures were measured. Interventions included balloon pulmonary valvuloplasty (n = 21), patent ductus arteriosus occlusion (n = 11), subaortic or sub‐pulmonary balloon dilatation (n = 4), and cor triatriatum membranostomy (n = 3). Angiographic measurements were larger when calibrated to EC versus TR (P < .0001). The mean bias was 0.86 mm, with greater bias for larger measurements. The EC measurements were ∼10% greater than TR based on regression analysis. Weight was correlated to the difference between methods (ρ = 0.55, P = .0003). CONCLUSIONS AND CLINICAL IMPORTANCE: Angiographic image calibration using a ruler placed on the fluoroscopy table underestimates the size of a structure by ∼10% as compared with a marker catheter placed within the esophagus. This effect is greatest when measuring larger structures such as the pulmonary valve annulus and in larger dogs. John Wiley and Sons Inc. 2018-03-12 2018 /pmc/articles/PMC5980279/ /pubmed/29528135 http://dx.doi.org/10.1111/jvim.15082 Text en Copyright © 2018 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle SMALL ANIMAL
Markovic, Lauren E.
Scansen, Brian A.
Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_fullStr Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_full_unstemmed Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_short Effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
title_sort effect of calibration methods on the accuracy of angiographic measurements during transcatheter procedures in dogs
topic SMALL ANIMAL
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980279/
https://www.ncbi.nlm.nih.gov/pubmed/29528135
http://dx.doi.org/10.1111/jvim.15082
work_keys_str_mv AT markoviclaurene effectofcalibrationmethodsontheaccuracyofangiographicmeasurementsduringtranscatheterproceduresindogs
AT scansenbriana effectofcalibrationmethodsontheaccuracyofangiographicmeasurementsduringtranscatheterproceduresindogs