Cargando…
Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
West Asia Organization for Cancer Prevention
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980870/ https://www.ncbi.nlm.nih.gov/pubmed/29281866 http://dx.doi.org/10.22034/APJCP.2017.18.12.3195 |
_version_ | 1783327927495032832 |
---|---|
author | Moghadam, Reza Nafisi Amlelshahbaz, Amir Pasha Namiranian, Nasim Sobhan-Ardekani, Mohammad Emami-Meybodi, Mahmood Dehghan, Ali Rahmanian, Masoud Razavi-Ratki, Seid Kazem |
author_facet | Moghadam, Reza Nafisi Amlelshahbaz, Amir Pasha Namiranian, Nasim Sobhan-Ardekani, Mohammad Emami-Meybodi, Mahmood Dehghan, Ali Rahmanian, Masoud Razavi-Ratki, Seid Kazem |
author_sort | Moghadam, Reza Nafisi |
collection | PubMed |
description | OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. METHODS: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). RESULTS: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. CONCLUSION: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar. |
format | Online Article Text |
id | pubmed-5980870 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | West Asia Organization for Cancer Prevention |
record_format | MEDLINE/PubMed |
spelling | pubmed-59808702018-06-06 Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis Moghadam, Reza Nafisi Amlelshahbaz, Amir Pasha Namiranian, Nasim Sobhan-Ardekani, Mohammad Emami-Meybodi, Mahmood Dehghan, Ali Rahmanian, Masoud Razavi-Ratki, Seid Kazem Asian Pac J Cancer Prev Review OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. METHODS: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). RESULTS: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. CONCLUSION: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar. West Asia Organization for Cancer Prevention 2017 /pmc/articles/PMC5980870/ /pubmed/29281866 http://dx.doi.org/10.22034/APJCP.2017.18.12.3195 Text en Copyright: © Asian Pacific Journal of Cancer Prevention http://creativecommons.org/licenses/BY-SA/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License |
spellingShingle | Review Moghadam, Reza Nafisi Amlelshahbaz, Amir Pasha Namiranian, Nasim Sobhan-Ardekani, Mohammad Emami-Meybodi, Mahmood Dehghan, Ali Rahmanian, Masoud Razavi-Ratki, Seid Kazem Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title | Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title_full | Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title_fullStr | Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title_full_unstemmed | Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title_short | Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis |
title_sort | comparative diagnostic performance of ultrasonography and 99mtc-sestamibi scintigraphy for parathyroid adenoma in primary hyperparathyroidism; systematic review and meta-analysis |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980870/ https://www.ncbi.nlm.nih.gov/pubmed/29281866 http://dx.doi.org/10.22034/APJCP.2017.18.12.3195 |
work_keys_str_mv | AT moghadamrezanafisi comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT amlelshahbazamirpasha comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT namiraniannasim comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT sobhanardekanimohammad comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT emamimeybodimahmood comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT dehghanali comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT rahmanianmasoud comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis AT razaviratkiseidkazem comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis |