Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis

OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid a...

Descripción completa

Detalles Bibliográficos
Autores principales: Moghadam, Reza Nafisi, Amlelshahbaz, Amir Pasha, Namiranian, Nasim, Sobhan-Ardekani, Mohammad, Emami-Meybodi, Mahmood, Dehghan, Ali, Rahmanian, Masoud, Razavi-Ratki, Seid Kazem
Formato: Online Artículo Texto
Lenguaje:English
Publicado: West Asia Organization for Cancer Prevention 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980870/
https://www.ncbi.nlm.nih.gov/pubmed/29281866
http://dx.doi.org/10.22034/APJCP.2017.18.12.3195
_version_ 1783327927495032832
author Moghadam, Reza Nafisi
Amlelshahbaz, Amir Pasha
Namiranian, Nasim
Sobhan-Ardekani, Mohammad
Emami-Meybodi, Mahmood
Dehghan, Ali
Rahmanian, Masoud
Razavi-Ratki, Seid Kazem
author_facet Moghadam, Reza Nafisi
Amlelshahbaz, Amir Pasha
Namiranian, Nasim
Sobhan-Ardekani, Mohammad
Emami-Meybodi, Mahmood
Dehghan, Ali
Rahmanian, Masoud
Razavi-Ratki, Seid Kazem
author_sort Moghadam, Reza Nafisi
collection PubMed
description OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. METHODS: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). RESULTS: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. CONCLUSION: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar.
format Online
Article
Text
id pubmed-5980870
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher West Asia Organization for Cancer Prevention
record_format MEDLINE/PubMed
spelling pubmed-59808702018-06-06 Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis Moghadam, Reza Nafisi Amlelshahbaz, Amir Pasha Namiranian, Nasim Sobhan-Ardekani, Mohammad Emami-Meybodi, Mahmood Dehghan, Ali Rahmanian, Masoud Razavi-Ratki, Seid Kazem Asian Pac J Cancer Prev Review OBJECTIVE: Ultrasonography (US) and parathyroid scintigraphy (PS) with 99mTc-MIBI are common methods for preoperative localization of parathyroid adenomas but there discrepancies exist with regard to diagnostic accuracy. The aim of the study was to compare PS and US for localization of parathyroid adenoma with a systematic review and meta-analysis of the literature. METHODS: Pub Med, Scopus (EMbase), Web of Science and the reference lists of all included studies were searched up to 1st January 2016. The search strategy was according PICO characteristics. Heterogeneity between the studies was accounted by P < 0.1. Point estimates were pooled estimate of sensitivity, specificity and positive predictive value of SPECT and ultrasonography with 99% confidence intervals (CIs) by pooling available data. Data analysis was performed using Meta-DiSc software (version 1.4). RESULTS: Among 188 studies and after deletion of duplicated studies (75), a total of 113 titles and abstracts were studied. From these, 12 studies were selected. The meta-analysis determined a pooled sensitivity for scintigraphy of 83% [99% confidence interval (CI) 96.358 -97.412] and for ultra-sonography of 80% [99% confidence interval (CI) 76-83]. Similar results for specificity were also obtained for both approache. CONCLUSION: According this meta- analysis, there were no significant differences between the two methods in terms of sensitivity and specificity. There were overlaps in 99% confidence intervals. Also features of the two methods are similar. West Asia Organization for Cancer Prevention 2017 /pmc/articles/PMC5980870/ /pubmed/29281866 http://dx.doi.org/10.22034/APJCP.2017.18.12.3195 Text en Copyright: © Asian Pacific Journal of Cancer Prevention http://creativecommons.org/licenses/BY-SA/4.0 This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License
spellingShingle Review
Moghadam, Reza Nafisi
Amlelshahbaz, Amir Pasha
Namiranian, Nasim
Sobhan-Ardekani, Mohammad
Emami-Meybodi, Mahmood
Dehghan, Ali
Rahmanian, Masoud
Razavi-Ratki, Seid Kazem
Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title_full Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title_fullStr Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title_full_unstemmed Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title_short Comparative Diagnostic Performance of Ultrasonography and 99mTc-Sestamibi Scintigraphy for Parathyroid Adenoma in Primary Hyperparathyroidism; Systematic Review and Meta-Analysis
title_sort comparative diagnostic performance of ultrasonography and 99mtc-sestamibi scintigraphy for parathyroid adenoma in primary hyperparathyroidism; systematic review and meta-analysis
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5980870/
https://www.ncbi.nlm.nih.gov/pubmed/29281866
http://dx.doi.org/10.22034/APJCP.2017.18.12.3195
work_keys_str_mv AT moghadamrezanafisi comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT amlelshahbazamirpasha comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT namiraniannasim comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT sobhanardekanimohammad comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT emamimeybodimahmood comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT dehghanali comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT rahmanianmasoud comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis
AT razaviratkiseidkazem comparativediagnosticperformanceofultrasonographyand99mtcsestamibiscintigraphyforparathyroidadenomainprimaryhyperparathyroidismsystematicreviewandmetaanalysis