Cargando…
Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles
Bubbly flows are commonly used in various applications and their measurement is an important research topic. The ultrasound pulse-echo technique allows for the detection of each bubble and the measurement of the position of its surface. However, so far it has been used only to measure single bubbles...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982422/ https://www.ncbi.nlm.nih.gov/pubmed/29693582 http://dx.doi.org/10.3390/s18051327 |
_version_ | 1783328238151401472 |
---|---|
author | Povolny, Antonin Kikura, Hiroshige Ihara, Tomonori |
author_facet | Povolny, Antonin Kikura, Hiroshige Ihara, Tomonori |
author_sort | Povolny, Antonin |
collection | PubMed |
description | Bubbly flows are commonly used in various applications and their measurement is an important research topic. The ultrasound pulse-echo technique allows for the detection of each bubble and the measurement of the position of its surface. However, so far it has been used only to measure single bubbles. This paper investigates whether the pulse-echo technique can be applied for measuring multiple bubbles concurrently. The ultrasonic transducer wavelength and diameter were selected based on expected bubble diameters so that each bubble produced a strong reflection. The pulse-echo was implemented to obtain good accuracy without sacrificing the signal processing speed. A tracking technique was developed for the purpose of connecting detected reflections to trajectories. The technique was tested experimentally by measuring the horizontal position of rising air bubbles in a water tank. The results show that the pulse-echo technique can detect multiple bubbles concurrently. The pulse-echo technique detected almost the same number of bubbles as a high-speed video. For average void fractions up to around [Formula: see text] (and instantaneous void fraction reaching [Formula: see text]), the rate of bubbles missed by the pulse-echo and the rate of noise trajectories both stayed less than 5%. The error rate increased with the void fraction, limiting the technique’s application range. |
format | Online Article Text |
id | pubmed-5982422 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-59824222018-06-05 Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles Povolny, Antonin Kikura, Hiroshige Ihara, Tomonori Sensors (Basel) Article Bubbly flows are commonly used in various applications and their measurement is an important research topic. The ultrasound pulse-echo technique allows for the detection of each bubble and the measurement of the position of its surface. However, so far it has been used only to measure single bubbles. This paper investigates whether the pulse-echo technique can be applied for measuring multiple bubbles concurrently. The ultrasonic transducer wavelength and diameter were selected based on expected bubble diameters so that each bubble produced a strong reflection. The pulse-echo was implemented to obtain good accuracy without sacrificing the signal processing speed. A tracking technique was developed for the purpose of connecting detected reflections to trajectories. The technique was tested experimentally by measuring the horizontal position of rising air bubbles in a water tank. The results show that the pulse-echo technique can detect multiple bubbles concurrently. The pulse-echo technique detected almost the same number of bubbles as a high-speed video. For average void fractions up to around [Formula: see text] (and instantaneous void fraction reaching [Formula: see text]), the rate of bubbles missed by the pulse-echo and the rate of noise trajectories both stayed less than 5%. The error rate increased with the void fraction, limiting the technique’s application range. MDPI 2018-04-25 /pmc/articles/PMC5982422/ /pubmed/29693582 http://dx.doi.org/10.3390/s18051327 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Povolny, Antonin Kikura, Hiroshige Ihara, Tomonori Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title | Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title_full | Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title_fullStr | Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title_full_unstemmed | Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title_short | Ultrasound Pulse-Echo Coupled with a Tracking Technique for Simultaneous Measurement of Multiple Bubbles |
title_sort | ultrasound pulse-echo coupled with a tracking technique for simultaneous measurement of multiple bubbles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982422/ https://www.ncbi.nlm.nih.gov/pubmed/29693582 http://dx.doi.org/10.3390/s18051327 |
work_keys_str_mv | AT povolnyantonin ultrasoundpulseechocoupledwithatrackingtechniqueforsimultaneousmeasurementofmultiplebubbles AT kikurahiroshige ultrasoundpulseechocoupledwithatrackingtechniqueforsimultaneousmeasurementofmultiplebubbles AT iharatomonori ultrasoundpulseechocoupledwithatrackingtechniqueforsimultaneousmeasurementofmultiplebubbles |