A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures
The birth of smart materials such as piezoelectric (PZT) transducers has aided in revolutionizing the field of structural health monitoring (SHM) based on non-destructive testing (NDT) methods. While a relatively new NDT method known as the electromechanical (EMI) technique has been investigated for...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982675/ https://www.ncbi.nlm.nih.gov/pubmed/29695067 http://dx.doi.org/10.3390/s18051307 |
_version_ | 1783328288051036160 |
---|---|
author | Na, Wongi S. Baek, Jongdae |
author_facet | Na, Wongi S. Baek, Jongdae |
author_sort | Na, Wongi S. |
collection | PubMed |
description | The birth of smart materials such as piezoelectric (PZT) transducers has aided in revolutionizing the field of structural health monitoring (SHM) based on non-destructive testing (NDT) methods. While a relatively new NDT method known as the electromechanical (EMI) technique has been investigated for more than two decades, there are still various problems that must be solved before it is applied to real structures. The technique, which has a significant potential to contribute to the creation of one of the most effective SHM systems, involves the use of a single PZT for exciting and sensing of the host structure. In this paper, studies applied for the past decade related to the EMI technique have been reviewed to understand its trend. In addition, new concepts and ideas proposed by various authors are also surveyed, and the paper concludes with a discussion of the potential directions for future works. |
format | Online Article Text |
id | pubmed-5982675 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-59826752018-06-05 A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures Na, Wongi S. Baek, Jongdae Sensors (Basel) Review The birth of smart materials such as piezoelectric (PZT) transducers has aided in revolutionizing the field of structural health monitoring (SHM) based on non-destructive testing (NDT) methods. While a relatively new NDT method known as the electromechanical (EMI) technique has been investigated for more than two decades, there are still various problems that must be solved before it is applied to real structures. The technique, which has a significant potential to contribute to the creation of one of the most effective SHM systems, involves the use of a single PZT for exciting and sensing of the host structure. In this paper, studies applied for the past decade related to the EMI technique have been reviewed to understand its trend. In addition, new concepts and ideas proposed by various authors are also surveyed, and the paper concludes with a discussion of the potential directions for future works. MDPI 2018-04-24 /pmc/articles/PMC5982675/ /pubmed/29695067 http://dx.doi.org/10.3390/s18051307 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Na, Wongi S. Baek, Jongdae A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title | A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title_full | A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title_fullStr | A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title_full_unstemmed | A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title_short | A Review of the Piezoelectric Electromechanical Impedance Based Structural Health Monitoring Technique for Engineering Structures |
title_sort | review of the piezoelectric electromechanical impedance based structural health monitoring technique for engineering structures |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982675/ https://www.ncbi.nlm.nih.gov/pubmed/29695067 http://dx.doi.org/10.3390/s18051307 |
work_keys_str_mv | AT nawongis areviewofthepiezoelectricelectromechanicalimpedancebasedstructuralhealthmonitoringtechniqueforengineeringstructures AT baekjongdae areviewofthepiezoelectricelectromechanicalimpedancebasedstructuralhealthmonitoringtechniqueforengineeringstructures AT nawongis reviewofthepiezoelectricelectromechanicalimpedancebasedstructuralhealthmonitoringtechniqueforengineeringstructures AT baekjongdae reviewofthepiezoelectricelectromechanicalimpedancebasedstructuralhealthmonitoringtechniqueforengineeringstructures |