Cargando…

A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors

Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all ti...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Wenguang, Liu, Shibin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982697/
https://www.ncbi.nlm.nih.gov/pubmed/29789448
http://dx.doi.org/10.3390/s18051659
_version_ 1783328293190107136
author Feng, Wenguang
Liu, Shibin
author_facet Feng, Wenguang
Liu, Shibin
author_sort Feng, Wenguang
collection PubMed
description Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all time-invariant errors is analyzed in detail, and then harmonic decomposition method is utilized to estimate the compensation coefficients. Meanwhile, the proposed nonlinear calibration algorithm is validated and compared with a classical calibration algorithm by experiments. The experimental results show that, after the nonlinear calibration, the maximum deviation of magnetic field magnitude is decreased from 1302 nT to 30 nT, which is smaller than 81 nT after the classical calibration. Furthermore, for the two-axis fluxgate sensor used as magnetic compass, the maximum error of heading is corrected from 1.86° to 0.07°, which is approximately 11% in contrast with 0.62° after the classical calibration. The results suggest an effective way to improve the calibration performance of two-axis fluxgate sensors.
format Online
Article
Text
id pubmed-5982697
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-59826972018-06-05 A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors Feng, Wenguang Liu, Shibin Sensors (Basel) Article Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all time-invariant errors is analyzed in detail, and then harmonic decomposition method is utilized to estimate the compensation coefficients. Meanwhile, the proposed nonlinear calibration algorithm is validated and compared with a classical calibration algorithm by experiments. The experimental results show that, after the nonlinear calibration, the maximum deviation of magnetic field magnitude is decreased from 1302 nT to 30 nT, which is smaller than 81 nT after the classical calibration. Furthermore, for the two-axis fluxgate sensor used as magnetic compass, the maximum error of heading is corrected from 1.86° to 0.07°, which is approximately 11% in contrast with 0.62° after the classical calibration. The results suggest an effective way to improve the calibration performance of two-axis fluxgate sensors. MDPI 2018-05-22 /pmc/articles/PMC5982697/ /pubmed/29789448 http://dx.doi.org/10.3390/s18051659 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Feng, Wenguang
Liu, Shibin
A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title_full A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title_fullStr A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title_full_unstemmed A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title_short A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
title_sort nonlinear calibration algorithm based on harmonic decomposition for two-axis fluxgate sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982697/
https://www.ncbi.nlm.nih.gov/pubmed/29789448
http://dx.doi.org/10.3390/s18051659
work_keys_str_mv AT fengwenguang anonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors
AT liushibin anonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors
AT fengwenguang nonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors
AT liushibin nonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors