Cargando…
A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors
Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all ti...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982697/ https://www.ncbi.nlm.nih.gov/pubmed/29789448 http://dx.doi.org/10.3390/s18051659 |
_version_ | 1783328293190107136 |
---|---|
author | Feng, Wenguang Liu, Shibin |
author_facet | Feng, Wenguang Liu, Shibin |
author_sort | Feng, Wenguang |
collection | PubMed |
description | Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all time-invariant errors is analyzed in detail, and then harmonic decomposition method is utilized to estimate the compensation coefficients. Meanwhile, the proposed nonlinear calibration algorithm is validated and compared with a classical calibration algorithm by experiments. The experimental results show that, after the nonlinear calibration, the maximum deviation of magnetic field magnitude is decreased from 1302 nT to 30 nT, which is smaller than 81 nT after the classical calibration. Furthermore, for the two-axis fluxgate sensor used as magnetic compass, the maximum error of heading is corrected from 1.86° to 0.07°, which is approximately 11% in contrast with 0.62° after the classical calibration. The results suggest an effective way to improve the calibration performance of two-axis fluxgate sensors. |
format | Online Article Text |
id | pubmed-5982697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-59826972018-06-05 A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors Feng, Wenguang Liu, Shibin Sensors (Basel) Article Nonlinearity is a prominent limitation to the calibration performance for two-axis fluxgate sensors. In this paper, a novel nonlinear calibration algorithm taking into account the nonlinearity of errors is proposed. In order to establish the nonlinear calibration model, the combined effort of all time-invariant errors is analyzed in detail, and then harmonic decomposition method is utilized to estimate the compensation coefficients. Meanwhile, the proposed nonlinear calibration algorithm is validated and compared with a classical calibration algorithm by experiments. The experimental results show that, after the nonlinear calibration, the maximum deviation of magnetic field magnitude is decreased from 1302 nT to 30 nT, which is smaller than 81 nT after the classical calibration. Furthermore, for the two-axis fluxgate sensor used as magnetic compass, the maximum error of heading is corrected from 1.86° to 0.07°, which is approximately 11% in contrast with 0.62° after the classical calibration. The results suggest an effective way to improve the calibration performance of two-axis fluxgate sensors. MDPI 2018-05-22 /pmc/articles/PMC5982697/ /pubmed/29789448 http://dx.doi.org/10.3390/s18051659 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Feng, Wenguang Liu, Shibin A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title | A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title_full | A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title_fullStr | A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title_full_unstemmed | A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title_short | A Nonlinear Calibration Algorithm Based on Harmonic Decomposition for Two-Axis Fluxgate Sensors |
title_sort | nonlinear calibration algorithm based on harmonic decomposition for two-axis fluxgate sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5982697/ https://www.ncbi.nlm.nih.gov/pubmed/29789448 http://dx.doi.org/10.3390/s18051659 |
work_keys_str_mv | AT fengwenguang anonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors AT liushibin anonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors AT fengwenguang nonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors AT liushibin nonlinearcalibrationalgorithmbasedonharmonicdecompositionfortwoaxisfluxgatesensors |