Cargando…

Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction

Posterior cruciate ligament (PCL) ruptures account for 1% to 44% of all acute ligament injuries of the knee. In this paper we wanted to try out a system for femural fixation. Hamstring tendons are harvested and standard tibial tunnel is prepared using the transtibial PCL guide; by identifying the PC...

Descripción completa

Detalles Bibliográficos
Autores principales: Adriani, Ezio, Di Paola, Berardino, Alfieri, Andrea, De Fenu, Edoardo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5984359/
https://www.ncbi.nlm.nih.gov/pubmed/29868394
http://dx.doi.org/10.1016/j.eats.2017.09.004
_version_ 1783328598648684544
author Adriani, Ezio
Di Paola, Berardino
Alfieri, Andrea
De Fenu, Edoardo
author_facet Adriani, Ezio
Di Paola, Berardino
Alfieri, Andrea
De Fenu, Edoardo
author_sort Adriani, Ezio
collection PubMed
description Posterior cruciate ligament (PCL) ruptures account for 1% to 44% of all acute ligament injuries of the knee. In this paper we wanted to try out a system for femural fixation. Hamstring tendons are harvested and standard tibial tunnel is prepared using the transtibial PCL guide; by identifying the PCL footprint, the femoral half tunnel 27 to 30 mm with in-out technique is performed. The femoral rod of a curve cross-pin system is inserted into the anterolateral access within the femoral half tunnel. The guide block is placed 2.5 cm anterior (in a coronal plane) and 2.5 cm proximal to the lateral epicondyle. The arc attachment is assembled and the bone stock assessed with the bone gauge pin in contact with the cortex of the medial femoral condyle. Then the first sleeve over trocar is assembled, and the graft is passed through the tunnel and fixed on the femur with the pins and on the tibia with interferential screw. After biomechanical studies we obtained a maximum load at 930.95 N and maximum stiffness at 58.92 N/mm.
format Online
Article
Text
id pubmed-5984359
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-59843592018-06-04 Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction Adriani, Ezio Di Paola, Berardino Alfieri, Andrea De Fenu, Edoardo Arthrosc Tech Technical Note Posterior cruciate ligament (PCL) ruptures account for 1% to 44% of all acute ligament injuries of the knee. In this paper we wanted to try out a system for femural fixation. Hamstring tendons are harvested and standard tibial tunnel is prepared using the transtibial PCL guide; by identifying the PCL footprint, the femoral half tunnel 27 to 30 mm with in-out technique is performed. The femoral rod of a curve cross-pin system is inserted into the anterolateral access within the femoral half tunnel. The guide block is placed 2.5 cm anterior (in a coronal plane) and 2.5 cm proximal to the lateral epicondyle. The arc attachment is assembled and the bone stock assessed with the bone gauge pin in contact with the cortex of the medial femoral condyle. Then the first sleeve over trocar is assembled, and the graft is passed through the tunnel and fixed on the femur with the pins and on the tibia with interferential screw. After biomechanical studies we obtained a maximum load at 930.95 N and maximum stiffness at 58.92 N/mm. Elsevier 2018-03-05 /pmc/articles/PMC5984359/ /pubmed/29868394 http://dx.doi.org/10.1016/j.eats.2017.09.004 Text en © 2017 by the Arthroscopy Association of North America. Published by Elsevier. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Adriani, Ezio
Di Paola, Berardino
Alfieri, Andrea
De Fenu, Edoardo
Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title_full Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title_fullStr Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title_full_unstemmed Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title_short Femoral Fixation With Curve Cross-Pin System in Arthroscopic Posterior Cruciate Ligament Reconstruction
title_sort femoral fixation with curve cross-pin system in arthroscopic posterior cruciate ligament reconstruction
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5984359/
https://www.ncbi.nlm.nih.gov/pubmed/29868394
http://dx.doi.org/10.1016/j.eats.2017.09.004
work_keys_str_mv AT adrianiezio femoralfixationwithcurvecrosspinsysteminarthroscopicposteriorcruciateligamentreconstruction
AT dipaolaberardino femoralfixationwithcurvecrosspinsysteminarthroscopicposteriorcruciateligamentreconstruction
AT alfieriandrea femoralfixationwithcurvecrosspinsysteminarthroscopicposteriorcruciateligamentreconstruction
AT defenuedoardo femoralfixationwithcurvecrosspinsysteminarthroscopicposteriorcruciateligamentreconstruction