Cargando…

The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system

BACKGROUND: Femoral neck fractures are the commonly encountered injury in orthopedic practice and result in significant morbidity and mortality. Currently, how to treat femoral neck fractures safely and effectively is still a challenge. The objective of this study is to evaluate the efficiency of dy...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Ya-Ping, Shu, Dong-Ping, Bei, Ming-Jian, Ji, Tao, Kan, Wu-Sheng, Li, Shao-Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5984372/
https://www.ncbi.nlm.nih.gov/pubmed/29855311
http://dx.doi.org/10.1186/s13018-018-0827-9
_version_ 1783328601703186432
author Xiao, Ya-Ping
Shu, Dong-Ping
Bei, Ming-Jian
Ji, Tao
Kan, Wu-Sheng
Li, Shao-Gang
author_facet Xiao, Ya-Ping
Shu, Dong-Ping
Bei, Ming-Jian
Ji, Tao
Kan, Wu-Sheng
Li, Shao-Gang
author_sort Xiao, Ya-Ping
collection PubMed
description BACKGROUND: Femoral neck fractures are the commonly encountered injury in orthopedic practice and result in significant morbidity and mortality. Currently, how to treat femoral neck fractures safely and effectively is still a challenge. The objective of this study is to evaluate the efficiency of dynamic compression locking system for femoral neck fractures. METHODS: This is a retrospective study conducted from May 2015 to October 2016. The study included 36 patients suffering from femoral neck fractures who underwent closed reduction and were fixed using dynamic compression locking system. All surgeries were performed by the same surgeon. The study was conducted by telephone and on-site follow-up. The Garden classification and anatomical site classification were categorized for all patients. We assessed radiographic outcomes of union, femoral neck shortening, screw back-out, and femoral head avascular necrosis. We also evaluated functional outcome using the Harris hip score. Other outcomes included the length of surgery, duration of hospital stay, injury to surgery time, intraoperative hemorrhage, time to clinical bone union, and other fracture complications. RESULTS: All patients were followed up 12 to 29 months with an average of 21.58 ± 5.41 months. All cases were caused by falls including 17 males and 19 females with an average age of 65.33 ± 9.30 years old ranging from 53 to 82 years old. Among them, injury to surgery time ranged between 1 and 4 days with an average of 2.58 ± 1.05 days. Duration of hospital stay was 8 to 21 days with an average of 15.33 ± 3.71 days. Intraoperative hemorrhage was 40 to 80 ml with an average of 61.67 ± 12.31 ml. Operation time was from 35 to 80 min with average of 50.25 ± 11.77 min. According to Garden classification, 9 cases (25%) were type II and 27 cases (75%) were type III. According to the anatomical site classification, 8 cases (22.2%) were subcapital femoral neck fractures, 19 cases (52.8%) trans-cervical, and 9 cases (25%) basi-cervical. At present, the follow-up has not found the fracture complications of femoral head avascular necrosis, fracture nonunion, and re-fracture. All patients achieved solid bone union. The mean time of clinical bone union was 3 to 4 months. Among all patients, there were only 3 cases of femoral neck shortening < 5 mm and 1 case of screw back-out = 4 mm. For Harris scoring, average Harris scale at the end of the follow-up was 93.42 ± 3.95 ranging from 85 to 98. There were 32 cases of excellent function scores on the Harris scale and 4 cases of good function scores on the Harris scale. Therefore, the excellent and good rate of Harris hip scores was 100%. CONCLUSIONS: Femoral neck dynamic compression locking system for femoral neck fractures in elderly patients can provide effective stability and reduce complications and revision rates.
format Online
Article
Text
id pubmed-5984372
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-59843722018-06-07 The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system Xiao, Ya-Ping Shu, Dong-Ping Bei, Ming-Jian Ji, Tao Kan, Wu-Sheng Li, Shao-Gang J Orthop Surg Res Research Article BACKGROUND: Femoral neck fractures are the commonly encountered injury in orthopedic practice and result in significant morbidity and mortality. Currently, how to treat femoral neck fractures safely and effectively is still a challenge. The objective of this study is to evaluate the efficiency of dynamic compression locking system for femoral neck fractures. METHODS: This is a retrospective study conducted from May 2015 to October 2016. The study included 36 patients suffering from femoral neck fractures who underwent closed reduction and were fixed using dynamic compression locking system. All surgeries were performed by the same surgeon. The study was conducted by telephone and on-site follow-up. The Garden classification and anatomical site classification were categorized for all patients. We assessed radiographic outcomes of union, femoral neck shortening, screw back-out, and femoral head avascular necrosis. We also evaluated functional outcome using the Harris hip score. Other outcomes included the length of surgery, duration of hospital stay, injury to surgery time, intraoperative hemorrhage, time to clinical bone union, and other fracture complications. RESULTS: All patients were followed up 12 to 29 months with an average of 21.58 ± 5.41 months. All cases were caused by falls including 17 males and 19 females with an average age of 65.33 ± 9.30 years old ranging from 53 to 82 years old. Among them, injury to surgery time ranged between 1 and 4 days with an average of 2.58 ± 1.05 days. Duration of hospital stay was 8 to 21 days with an average of 15.33 ± 3.71 days. Intraoperative hemorrhage was 40 to 80 ml with an average of 61.67 ± 12.31 ml. Operation time was from 35 to 80 min with average of 50.25 ± 11.77 min. According to Garden classification, 9 cases (25%) were type II and 27 cases (75%) were type III. According to the anatomical site classification, 8 cases (22.2%) were subcapital femoral neck fractures, 19 cases (52.8%) trans-cervical, and 9 cases (25%) basi-cervical. At present, the follow-up has not found the fracture complications of femoral head avascular necrosis, fracture nonunion, and re-fracture. All patients achieved solid bone union. The mean time of clinical bone union was 3 to 4 months. Among all patients, there were only 3 cases of femoral neck shortening < 5 mm and 1 case of screw back-out = 4 mm. For Harris scoring, average Harris scale at the end of the follow-up was 93.42 ± 3.95 ranging from 85 to 98. There were 32 cases of excellent function scores on the Harris scale and 4 cases of good function scores on the Harris scale. Therefore, the excellent and good rate of Harris hip scores was 100%. CONCLUSIONS: Femoral neck dynamic compression locking system for femoral neck fractures in elderly patients can provide effective stability and reduce complications and revision rates. BioMed Central 2018-05-31 /pmc/articles/PMC5984372/ /pubmed/29855311 http://dx.doi.org/10.1186/s13018-018-0827-9 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Xiao, Ya-Ping
Shu, Dong-Ping
Bei, Ming-Jian
Ji, Tao
Kan, Wu-Sheng
Li, Shao-Gang
The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title_full The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title_fullStr The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title_full_unstemmed The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title_short The clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
title_sort clinical application of a novel method of internal fixation for femoral neck fractures—dynamic locking compression system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5984372/
https://www.ncbi.nlm.nih.gov/pubmed/29855311
http://dx.doi.org/10.1186/s13018-018-0827-9
work_keys_str_mv AT xiaoyaping theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT shudongping theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT beimingjian theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT jitao theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT kanwusheng theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT lishaogang theclinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT xiaoyaping clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT shudongping clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT beimingjian clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT jitao clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT kanwusheng clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem
AT lishaogang clinicalapplicationofanovelmethodofinternalfixationforfemoralneckfracturesdynamiclockingcompressionsystem