A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience

This study aimed to identify cardiotocography patterns that discriminate fetal acidemia newborns by comprehensively evaluating the parameters obtained from Holter monitoring during delivery. Between June 1, 2015, and August 1, 2016, a prospective observational study of 85 patients was conducted usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Ning, Zhang, Weiyuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5985095/
https://www.ncbi.nlm.nih.gov/pubmed/29888259
http://dx.doi.org/10.1155/2018/3478925
_version_ 1783328704260210688
author Tian, Ning
Zhang, Weiyuan
author_facet Tian, Ning
Zhang, Weiyuan
author_sort Tian, Ning
collection PubMed
description This study aimed to identify cardiotocography patterns that discriminate fetal acidemia newborns by comprehensively evaluating the parameters obtained from Holter monitoring during delivery. Between June 1, 2015, and August 1, 2016, a prospective observational study of 85 patients was conducted using fetal Holter monitoring at the Beijing Obstetrics and Gynecology Hospital, Capital Medical University, China. Umbilical cord blood was sampled immediately after delivery and fetal acidemia was defined as umbilical cord arterial blood pH < 7.20. Fetal electrocardiogram- (FECG-) derived parameters, including basal fetal heart rate (BFHR), short-term variation (STV), large acceleration (LA), deceleration capacity (DC), acceleration capacity (AC), proportion of episodes of high variation (PEHV), and proportion of episodes of low variation (PELV), were compared between 16 fetuses with acidemia and 47 without. The areas under the curve (AUC) of receiver operating characteristics (ROC) were calculated. Although all the computerized parameters showed predictive values for acidemia (all AUC > 0.50), STV (AUC = 0.84, P < 0.001), DC (AUC = 0.84, P < 0.001), AC (AUC = 0.80, P < 0.001), and PELV (AUC = 0.71, P = 0.012) were more strongly associated with fetal acidemia. Our institutional experience suggests that FECG-derived parameters from Holter monitoring are beneficial in reducing the incidence of neonatal acidemia.
format Online
Article
Text
id pubmed-5985095
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-59850952018-06-10 A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience Tian, Ning Zhang, Weiyuan Biomed Res Int Research Article This study aimed to identify cardiotocography patterns that discriminate fetal acidemia newborns by comprehensively evaluating the parameters obtained from Holter monitoring during delivery. Between June 1, 2015, and August 1, 2016, a prospective observational study of 85 patients was conducted using fetal Holter monitoring at the Beijing Obstetrics and Gynecology Hospital, Capital Medical University, China. Umbilical cord blood was sampled immediately after delivery and fetal acidemia was defined as umbilical cord arterial blood pH < 7.20. Fetal electrocardiogram- (FECG-) derived parameters, including basal fetal heart rate (BFHR), short-term variation (STV), large acceleration (LA), deceleration capacity (DC), acceleration capacity (AC), proportion of episodes of high variation (PEHV), and proportion of episodes of low variation (PELV), were compared between 16 fetuses with acidemia and 47 without. The areas under the curve (AUC) of receiver operating characteristics (ROC) were calculated. Although all the computerized parameters showed predictive values for acidemia (all AUC > 0.50), STV (AUC = 0.84, P < 0.001), DC (AUC = 0.84, P < 0.001), AC (AUC = 0.80, P < 0.001), and PELV (AUC = 0.71, P = 0.012) were more strongly associated with fetal acidemia. Our institutional experience suggests that FECG-derived parameters from Holter monitoring are beneficial in reducing the incidence of neonatal acidemia. Hindawi 2018-05-17 /pmc/articles/PMC5985095/ /pubmed/29888259 http://dx.doi.org/10.1155/2018/3478925 Text en Copyright © 2018 Ning Tian and Weiyuan Zhang. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Tian, Ning
Zhang, Weiyuan
A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title_full A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title_fullStr A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title_full_unstemmed A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title_short A Comprehensive Evaluation of the Predictive Abilities of Fetal Electrocardiogram-Derived Parameters during Labor in Newborn Acidemia: Our Institutional Experience
title_sort comprehensive evaluation of the predictive abilities of fetal electrocardiogram-derived parameters during labor in newborn acidemia: our institutional experience
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5985095/
https://www.ncbi.nlm.nih.gov/pubmed/29888259
http://dx.doi.org/10.1155/2018/3478925
work_keys_str_mv AT tianning acomprehensiveevaluationofthepredictiveabilitiesoffetalelectrocardiogramderivedparametersduringlaborinnewbornacidemiaourinstitutionalexperience
AT zhangweiyuan acomprehensiveevaluationofthepredictiveabilitiesoffetalelectrocardiogramderivedparametersduringlaborinnewbornacidemiaourinstitutionalexperience
AT tianning comprehensiveevaluationofthepredictiveabilitiesoffetalelectrocardiogramderivedparametersduringlaborinnewbornacidemiaourinstitutionalexperience
AT zhangweiyuan comprehensiveevaluationofthepredictiveabilitiesoffetalelectrocardiogramderivedparametersduringlaborinnewbornacidemiaourinstitutionalexperience