Cargando…

3D-evaluation of the maxillary sinus in cone-beam computed tomography

BACKGROUND: There are few studies measuring the dimensions of the maxillary sinus, being mostly based on computed tomography imaging and rarely being based on cone-beam computed tomography (CBCT). The aim of this study was to measure the 3D osseous and soft tissue defined volume and surface area of...

Descripción completa

Detalles Bibliográficos
Autores principales: Luz, Julia, Greutmann, Dominique, Wiedemeier, Daniel, Rostetter, Claudio, Rücker, Martin, Stadlinger, Bernd
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986688/
https://www.ncbi.nlm.nih.gov/pubmed/29869022
http://dx.doi.org/10.1186/s40729-018-0128-4
_version_ 1783328966328713216
author Luz, Julia
Greutmann, Dominique
Wiedemeier, Daniel
Rostetter, Claudio
Rücker, Martin
Stadlinger, Bernd
author_facet Luz, Julia
Greutmann, Dominique
Wiedemeier, Daniel
Rostetter, Claudio
Rücker, Martin
Stadlinger, Bernd
author_sort Luz, Julia
collection PubMed
description BACKGROUND: There are few studies measuring the dimensions of the maxillary sinus, being mostly based on computed tomography imaging and rarely being based on cone-beam computed tomography (CBCT). The aim of this study was to measure the 3D osseous and soft tissue defined volume and surface area of the maxillary sinus. Further, possible associations with patient-specific and sinus-related variables were evaluated. METHODS: A total of 128 maxillary sinuses in 64 patients were analyzed using cone-beam computed tomography data. Surface area and volume of the osseus maxillary sinuses as well as of the remaining pneumatized cavities in cases of obliterated sinuses were calculated by the implant planning software SMOP (Swissmeda AG, Baar, Switzerland). Further, patient-specific general variables such as age, gender, and dentition state as well as sinus-related factors including apical lesions, sinus pathologies, and number of teeth and roots communicating with the maxillary sinus were recorded. RESULTS: For osseus bordered sinuses, mean surface area was 39.7 cm(2) and mean volume 17.1 cm(3). For the remaining pneumatized cavities, mean surface area was 36.4 cm(2) and mean volume 15 cm(3). The calculated mean volume of obliterated sinuses (42.2% of all sinuses were obliterated) was 5.1 cm(3). Further, an association between the obliterated volume and the presence of pathologies was detected. Male patients showed a significantly higher mean osseus volume compared to female patients. No association was apparent between a patient’s age or dentition state and sinus volume, nor for communicating tooth roots and sinus pathologies or unilateral opacity and apical radiolucency. There was also no significant association between bilateral obliterated sinuses and the scan date being in autumn/winter. CONCLUSIONS: The present study showed that the CBCT is suitable for the evaluation of the maxillary sinus. The implant planning software SMOP and its included volume measuring tool are valuable for the analysis of the maxillary sinus, and possible relations with the dentition can be analyzed.
format Online
Article
Text
id pubmed-5986688
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-59866882018-06-13 3D-evaluation of the maxillary sinus in cone-beam computed tomography Luz, Julia Greutmann, Dominique Wiedemeier, Daniel Rostetter, Claudio Rücker, Martin Stadlinger, Bernd Int J Implant Dent Research BACKGROUND: There are few studies measuring the dimensions of the maxillary sinus, being mostly based on computed tomography imaging and rarely being based on cone-beam computed tomography (CBCT). The aim of this study was to measure the 3D osseous and soft tissue defined volume and surface area of the maxillary sinus. Further, possible associations with patient-specific and sinus-related variables were evaluated. METHODS: A total of 128 maxillary sinuses in 64 patients were analyzed using cone-beam computed tomography data. Surface area and volume of the osseus maxillary sinuses as well as of the remaining pneumatized cavities in cases of obliterated sinuses were calculated by the implant planning software SMOP (Swissmeda AG, Baar, Switzerland). Further, patient-specific general variables such as age, gender, and dentition state as well as sinus-related factors including apical lesions, sinus pathologies, and number of teeth and roots communicating with the maxillary sinus were recorded. RESULTS: For osseus bordered sinuses, mean surface area was 39.7 cm(2) and mean volume 17.1 cm(3). For the remaining pneumatized cavities, mean surface area was 36.4 cm(2) and mean volume 15 cm(3). The calculated mean volume of obliterated sinuses (42.2% of all sinuses were obliterated) was 5.1 cm(3). Further, an association between the obliterated volume and the presence of pathologies was detected. Male patients showed a significantly higher mean osseus volume compared to female patients. No association was apparent between a patient’s age or dentition state and sinus volume, nor for communicating tooth roots and sinus pathologies or unilateral opacity and apical radiolucency. There was also no significant association between bilateral obliterated sinuses and the scan date being in autumn/winter. CONCLUSIONS: The present study showed that the CBCT is suitable for the evaluation of the maxillary sinus. The implant planning software SMOP and its included volume measuring tool are valuable for the analysis of the maxillary sinus, and possible relations with the dentition can be analyzed. Springer Berlin Heidelberg 2018-06-05 /pmc/articles/PMC5986688/ /pubmed/29869022 http://dx.doi.org/10.1186/s40729-018-0128-4 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Luz, Julia
Greutmann, Dominique
Wiedemeier, Daniel
Rostetter, Claudio
Rücker, Martin
Stadlinger, Bernd
3D-evaluation of the maxillary sinus in cone-beam computed tomography
title 3D-evaluation of the maxillary sinus in cone-beam computed tomography
title_full 3D-evaluation of the maxillary sinus in cone-beam computed tomography
title_fullStr 3D-evaluation of the maxillary sinus in cone-beam computed tomography
title_full_unstemmed 3D-evaluation of the maxillary sinus in cone-beam computed tomography
title_short 3D-evaluation of the maxillary sinus in cone-beam computed tomography
title_sort 3d-evaluation of the maxillary sinus in cone-beam computed tomography
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986688/
https://www.ncbi.nlm.nih.gov/pubmed/29869022
http://dx.doi.org/10.1186/s40729-018-0128-4
work_keys_str_mv AT luzjulia 3devaluationofthemaxillarysinusinconebeamcomputedtomography
AT greutmanndominique 3devaluationofthemaxillarysinusinconebeamcomputedtomography
AT wiedemeierdaniel 3devaluationofthemaxillarysinusinconebeamcomputedtomography
AT rostetterclaudio 3devaluationofthemaxillarysinusinconebeamcomputedtomography
AT ruckermartin 3devaluationofthemaxillarysinusinconebeamcomputedtomography
AT stadlingerbernd 3devaluationofthemaxillarysinusinconebeamcomputedtomography