Cargando…

Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI

Predictive computational modeling has revolutionized classical engineering disciplines and is in the process of transforming cardiovascular research. This is particularly relevant for investigating emergent therapies for heart failure, which remains a leading cause of death globally. The creation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Sack, Kevin L., Aliotta, Eric, Ennis, Daniel B., Choy, Jenny S., Kassab, Ghassan S., Guccione, Julius M., Franz, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986944/
https://www.ncbi.nlm.nih.gov/pubmed/29896107
http://dx.doi.org/10.3389/fphys.2018.00539
_version_ 1783329021365321728
author Sack, Kevin L.
Aliotta, Eric
Ennis, Daniel B.
Choy, Jenny S.
Kassab, Ghassan S.
Guccione, Julius M.
Franz, Thomas
author_facet Sack, Kevin L.
Aliotta, Eric
Ennis, Daniel B.
Choy, Jenny S.
Kassab, Ghassan S.
Guccione, Julius M.
Franz, Thomas
author_sort Sack, Kevin L.
collection PubMed
description Predictive computational modeling has revolutionized classical engineering disciplines and is in the process of transforming cardiovascular research. This is particularly relevant for investigating emergent therapies for heart failure, which remains a leading cause of death globally. The creation of subject-specific biventricular computational cardiac models has been a long-term endeavor within the biomedical engineering community. Using high resolution (0.3 × 0.3 × 0.8 mm) ex vivo data, we constructed a precise fully subject-specific biventricular finite-element model of healthy and failing swine hearts. Each model includes fully subject-specific geometries, myofiber architecture and, in the case of the failing heart, fibrotic tissue distribution. Passive and active material properties are prescribed using hyperelastic strain energy functions that define a nearly incompressible, orthotropic material capable of contractile function. These materials were calibrated using a sophisticated multistep approach to match orthotropic tri-axial shear data as well as subject-specific hemodynamic ventricular targets for pressure and volume to ensure realistic cardiac function. Each mechanically beating heart is coupled with a lumped-parameter representation of the circulatory system, allowing for a closed-loop definition of cardiovascular flow. The circulatory model incorporates unidirectional fluid exchanges driven by pressure gradients of the model, which in turn are driven by the mechanically beating heart. This creates a computationally meaningful representation of the dynamic beating of the heart coupled with the circulatory system. Each model was calibrated using subject-specific experimental data and compared with independent in vivo strain data obtained from echocardiography. Our methods produced highly detailed representations of swine hearts that function mechanically in a remarkably similar manner to the in vivo subject-specific strains on a global and regional comparison. The degree of subject-specificity included in the models represents a milestone for modeling efforts that captures realism of the whole heart. This study establishes a foundation for future computational studies that can apply these validated methods to advance cardiac mechanics research.
format Online
Article
Text
id pubmed-5986944
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-59869442018-06-12 Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI Sack, Kevin L. Aliotta, Eric Ennis, Daniel B. Choy, Jenny S. Kassab, Ghassan S. Guccione, Julius M. Franz, Thomas Front Physiol Physiology Predictive computational modeling has revolutionized classical engineering disciplines and is in the process of transforming cardiovascular research. This is particularly relevant for investigating emergent therapies for heart failure, which remains a leading cause of death globally. The creation of subject-specific biventricular computational cardiac models has been a long-term endeavor within the biomedical engineering community. Using high resolution (0.3 × 0.3 × 0.8 mm) ex vivo data, we constructed a precise fully subject-specific biventricular finite-element model of healthy and failing swine hearts. Each model includes fully subject-specific geometries, myofiber architecture and, in the case of the failing heart, fibrotic tissue distribution. Passive and active material properties are prescribed using hyperelastic strain energy functions that define a nearly incompressible, orthotropic material capable of contractile function. These materials were calibrated using a sophisticated multistep approach to match orthotropic tri-axial shear data as well as subject-specific hemodynamic ventricular targets for pressure and volume to ensure realistic cardiac function. Each mechanically beating heart is coupled with a lumped-parameter representation of the circulatory system, allowing for a closed-loop definition of cardiovascular flow. The circulatory model incorporates unidirectional fluid exchanges driven by pressure gradients of the model, which in turn are driven by the mechanically beating heart. This creates a computationally meaningful representation of the dynamic beating of the heart coupled with the circulatory system. Each model was calibrated using subject-specific experimental data and compared with independent in vivo strain data obtained from echocardiography. Our methods produced highly detailed representations of swine hearts that function mechanically in a remarkably similar manner to the in vivo subject-specific strains on a global and regional comparison. The degree of subject-specificity included in the models represents a milestone for modeling efforts that captures realism of the whole heart. This study establishes a foundation for future computational studies that can apply these validated methods to advance cardiac mechanics research. Frontiers Media S.A. 2018-05-29 /pmc/articles/PMC5986944/ /pubmed/29896107 http://dx.doi.org/10.3389/fphys.2018.00539 Text en Copyright © 2018 Sack, Aliotta, Ennis, Choy, Kassab, Guccione and Franz. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Sack, Kevin L.
Aliotta, Eric
Ennis, Daniel B.
Choy, Jenny S.
Kassab, Ghassan S.
Guccione, Julius M.
Franz, Thomas
Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title_full Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title_fullStr Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title_full_unstemmed Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title_short Construction and Validation of Subject-Specific Biventricular Finite-Element Models of Healthy and Failing Swine Hearts From High-Resolution DT-MRI
title_sort construction and validation of subject-specific biventricular finite-element models of healthy and failing swine hearts from high-resolution dt-mri
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5986944/
https://www.ncbi.nlm.nih.gov/pubmed/29896107
http://dx.doi.org/10.3389/fphys.2018.00539
work_keys_str_mv AT sackkevinl constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT aliottaeric constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT ennisdanielb constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT choyjennys constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT kassabghassans constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT guccionejuliusm constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri
AT franzthomas constructionandvalidationofsubjectspecificbiventricularfiniteelementmodelsofhealthyandfailingswineheartsfromhighresolutiondtmri