Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement

The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiogr...

Descripción completa

Detalles Bibliográficos
Autores principales: Sherifi, Ines, Omar, Alaa Mabrouk Salem, Varghese, Mithun, Weiner, Menachem, Anyanwu, Ani, Kovacic, Jason C, Sharma, Samin, Kini, Annapoorna, Sengupta, Partho P
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bioscientifica Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987181/
https://www.ncbi.nlm.nih.gov/pubmed/29743180
http://dx.doi.org/10.1530/ERP-17-0080
_version_ 1783329070897954816
author Sherifi, Ines
Omar, Alaa Mabrouk Salem
Varghese, Mithun
Weiner, Menachem
Anyanwu, Ani
Kovacic, Jason C
Sharma, Samin
Kini, Annapoorna
Sengupta, Partho P
author_facet Sherifi, Ines
Omar, Alaa Mabrouk Salem
Varghese, Mithun
Weiner, Menachem
Anyanwu, Ani
Kovacic, Jason C
Sharma, Samin
Kini, Annapoorna
Sengupta, Partho P
author_sort Sherifi, Ines
collection PubMed
description The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiography (TEE) under moderate sedation is not widely utilized. The aim of our study was to compare the value of TTE in comparison with TEE guidance under moderate sedation during TAVR. The study population included 144 consecutive patients (mean age 83 ± 11 years, 78 (54%) females) who had TAVR under moderate sedation using either a TTE (n = 96) or TEE (n = 48). We compared procedural outcomes using propensity score matching. There were no significant inter-group differences in age, sex, ejection fraction, aortic valve area, pressure gradients, creatinine or type of valve used. The procedural time was significantly shorter in the TEE group (P < 0.001) and associated with a lower need for periprocedural aortograms (7.7 ± 1.9 vs 8.2 ± 1.9, P = 0.022) and a lower occurrence of acute kidney injury (1 vs 11, P = 0.047). The 1:1 propensity score matching also showed a lower procedural time (P = 0.032), number of aortograms (P = 0.014) and a trend toward lower acute kidney injury in the TEE group (P = 0.077). TAVR guidance using TEE is associated with a lower fluoroscopic time, a lower need for additional aortograms and trend in lower occurrence of post-TAVR acute kidney injury.
format Online
Article
Text
id pubmed-5987181
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Bioscientifica Ltd
record_format MEDLINE/PubMed
spelling pubmed-59871812018-06-08 Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement Sherifi, Ines Omar, Alaa Mabrouk Salem Varghese, Mithun Weiner, Menachem Anyanwu, Ani Kovacic, Jason C Sharma, Samin Kini, Annapoorna Sengupta, Partho P Echo Res Pract Research The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiography (TEE) under moderate sedation is not widely utilized. The aim of our study was to compare the value of TTE in comparison with TEE guidance under moderate sedation during TAVR. The study population included 144 consecutive patients (mean age 83 ± 11 years, 78 (54%) females) who had TAVR under moderate sedation using either a TTE (n = 96) or TEE (n = 48). We compared procedural outcomes using propensity score matching. There were no significant inter-group differences in age, sex, ejection fraction, aortic valve area, pressure gradients, creatinine or type of valve used. The procedural time was significantly shorter in the TEE group (P < 0.001) and associated with a lower need for periprocedural aortograms (7.7 ± 1.9 vs 8.2 ± 1.9, P = 0.022) and a lower occurrence of acute kidney injury (1 vs 11, P = 0.047). The 1:1 propensity score matching also showed a lower procedural time (P = 0.032), number of aortograms (P = 0.014) and a trend toward lower acute kidney injury in the TEE group (P = 0.077). TAVR guidance using TEE is associated with a lower fluoroscopic time, a lower need for additional aortograms and trend in lower occurrence of post-TAVR acute kidney injury. Bioscientifica Ltd 2018-05-09 /pmc/articles/PMC5987181/ /pubmed/29743180 http://dx.doi.org/10.1530/ERP-17-0080 Text en © 2018 The authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Research
Sherifi, Ines
Omar, Alaa Mabrouk Salem
Varghese, Mithun
Weiner, Menachem
Anyanwu, Ani
Kovacic, Jason C
Sharma, Samin
Kini, Annapoorna
Sengupta, Partho P
Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title_full Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title_fullStr Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title_full_unstemmed Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title_short Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
title_sort comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987181/
https://www.ncbi.nlm.nih.gov/pubmed/29743180
http://dx.doi.org/10.1530/ERP-17-0080
work_keys_str_mv AT sherifiines comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT omaralaamabrouksalem comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT varghesemithun comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT weinermenachem comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT anyanwuani comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT kovacicjasonc comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT sharmasamin comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT kiniannapoorna comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement
AT senguptaparthop comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement