Cargando…
Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement
The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiogr...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bioscientifica Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987181/ https://www.ncbi.nlm.nih.gov/pubmed/29743180 http://dx.doi.org/10.1530/ERP-17-0080 |
_version_ | 1783329070897954816 |
---|---|
author | Sherifi, Ines Omar, Alaa Mabrouk Salem Varghese, Mithun Weiner, Menachem Anyanwu, Ani Kovacic, Jason C Sharma, Samin Kini, Annapoorna Sengupta, Partho P |
author_facet | Sherifi, Ines Omar, Alaa Mabrouk Salem Varghese, Mithun Weiner, Menachem Anyanwu, Ani Kovacic, Jason C Sharma, Samin Kini, Annapoorna Sengupta, Partho P |
author_sort | Sherifi, Ines |
collection | PubMed |
description | The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiography (TEE) under moderate sedation is not widely utilized. The aim of our study was to compare the value of TTE in comparison with TEE guidance under moderate sedation during TAVR. The study population included 144 consecutive patients (mean age 83 ± 11 years, 78 (54%) females) who had TAVR under moderate sedation using either a TTE (n = 96) or TEE (n = 48). We compared procedural outcomes using propensity score matching. There were no significant inter-group differences in age, sex, ejection fraction, aortic valve area, pressure gradients, creatinine or type of valve used. The procedural time was significantly shorter in the TEE group (P < 0.001) and associated with a lower need for periprocedural aortograms (7.7 ± 1.9 vs 8.2 ± 1.9, P = 0.022) and a lower occurrence of acute kidney injury (1 vs 11, P = 0.047). The 1:1 propensity score matching also showed a lower procedural time (P = 0.032), number of aortograms (P = 0.014) and a trend toward lower acute kidney injury in the TEE group (P = 0.077). TAVR guidance using TEE is associated with a lower fluoroscopic time, a lower need for additional aortograms and trend in lower occurrence of post-TAVR acute kidney injury. |
format | Online Article Text |
id | pubmed-5987181 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Bioscientifica Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-59871812018-06-08 Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement Sherifi, Ines Omar, Alaa Mabrouk Salem Varghese, Mithun Weiner, Menachem Anyanwu, Ani Kovacic, Jason C Sharma, Samin Kini, Annapoorna Sengupta, Partho P Echo Res Pract Research The optimal periprocedural imaging strategy during transcathether aortic valve replacement (TAVR) performed under moderate sedation is debated. Transthoracic echocardiography (TTE) provides suboptimal views due to poorer resolution and patient positioning, whereas use of transesophageal echocardiography (TEE) under moderate sedation is not widely utilized. The aim of our study was to compare the value of TTE in comparison with TEE guidance under moderate sedation during TAVR. The study population included 144 consecutive patients (mean age 83 ± 11 years, 78 (54%) females) who had TAVR under moderate sedation using either a TTE (n = 96) or TEE (n = 48). We compared procedural outcomes using propensity score matching. There were no significant inter-group differences in age, sex, ejection fraction, aortic valve area, pressure gradients, creatinine or type of valve used. The procedural time was significantly shorter in the TEE group (P < 0.001) and associated with a lower need for periprocedural aortograms (7.7 ± 1.9 vs 8.2 ± 1.9, P = 0.022) and a lower occurrence of acute kidney injury (1 vs 11, P = 0.047). The 1:1 propensity score matching also showed a lower procedural time (P = 0.032), number of aortograms (P = 0.014) and a trend toward lower acute kidney injury in the TEE group (P = 0.077). TAVR guidance using TEE is associated with a lower fluoroscopic time, a lower need for additional aortograms and trend in lower occurrence of post-TAVR acute kidney injury. Bioscientifica Ltd 2018-05-09 /pmc/articles/PMC5987181/ /pubmed/29743180 http://dx.doi.org/10.1530/ERP-17-0080 Text en © 2018 The authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (http://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Research Sherifi, Ines Omar, Alaa Mabrouk Salem Varghese, Mithun Weiner, Menachem Anyanwu, Ani Kovacic, Jason C Sharma, Samin Kini, Annapoorna Sengupta, Partho P Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title | Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title_full | Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title_fullStr | Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title_full_unstemmed | Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title_short | Comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
title_sort | comparison of transesophageal and transthoracic echocardiography under moderate sedation for guiding transcatheter aortic valve replacement |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987181/ https://www.ncbi.nlm.nih.gov/pubmed/29743180 http://dx.doi.org/10.1530/ERP-17-0080 |
work_keys_str_mv | AT sherifiines comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT omaralaamabrouksalem comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT varghesemithun comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT weinermenachem comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT anyanwuani comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT kovacicjasonc comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT sharmasamin comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT kiniannapoorna comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement AT senguptaparthop comparisonoftransesophagealandtransthoracicechocardiographyundermoderatesedationforguidingtranscatheteraorticvalvereplacement |