Cargando…
Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters
Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987336/ https://www.ncbi.nlm.nih.gov/pubmed/29951314 http://dx.doi.org/10.1155/2018/7380527 |
_version_ | 1783329092056121344 |
---|---|
author | Adams, Suzanne Toroni, Bridget Lele, Meenal |
author_facet | Adams, Suzanne Toroni, Bridget Lele, Meenal |
author_sort | Adams, Suzanne |
collection | PubMed |
description | Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a number of hospitals. This study aimed to determine the appropriate wait time following a flush and the minimum waste volume required to obtain an undiluted blood sample when using the PIVO device and how that differed from current guidelines from SPC line draws. A clinical study was conducted examining the analyte results of samples drawn with PIVO through a SPC at varying wait times following a saline flush. Both an initial waste volume and a postwaste sample were compared to a venipuncture control. The resulting samples showed no saline dilution as measured by sodium and creatinine results at all studied wait times. These findings suggest that blood collections using the PIVO device can produce a clinically valid sample with a 30-second wait following a SPC flush and no waste volume prior to sample collection. |
format | Online Article Text |
id | pubmed-5987336 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-59873362018-06-27 Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters Adams, Suzanne Toroni, Bridget Lele, Meenal Nurs Res Pract Research Article Short peripheral catheters (SPC) are an existing conduit into many patients' veins and line draws from SPC are a desired method of routine blood collection especially in difficult venous access patients. The PIVO device facilitates blood collection through SPC and is being used clinically in a number of hospitals. This study aimed to determine the appropriate wait time following a flush and the minimum waste volume required to obtain an undiluted blood sample when using the PIVO device and how that differed from current guidelines from SPC line draws. A clinical study was conducted examining the analyte results of samples drawn with PIVO through a SPC at varying wait times following a saline flush. Both an initial waste volume and a postwaste sample were compared to a venipuncture control. The resulting samples showed no saline dilution as measured by sodium and creatinine results at all studied wait times. These findings suggest that blood collections using the PIVO device can produce a clinically valid sample with a 30-second wait following a SPC flush and no waste volume prior to sample collection. Hindawi 2018-05-22 /pmc/articles/PMC5987336/ /pubmed/29951314 http://dx.doi.org/10.1155/2018/7380527 Text en Copyright © 2018 Suzanne Adams et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Adams, Suzanne Toroni, Bridget Lele, Meenal Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title | Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title_full | Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title_fullStr | Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title_full_unstemmed | Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title_short | Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters |
title_sort | effect of the pivo device on the procedure of phlebotomy from peripheral iv catheters |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5987336/ https://www.ncbi.nlm.nih.gov/pubmed/29951314 http://dx.doi.org/10.1155/2018/7380527 |
work_keys_str_mv | AT adamssuzanne effectofthepivodeviceontheprocedureofphlebotomyfromperipheralivcatheters AT toronibridget effectofthepivodeviceontheprocedureofphlebotomyfromperipheralivcatheters AT lelemeenal effectofthepivodeviceontheprocedureofphlebotomyfromperipheralivcatheters |