Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments
The superior soft tissue contrast provided by magnetic resonance (MR) images on the 1.5T MR-linac allows for the incorporation of patient anatomy information. In this retrospective case study, we present the simulated dosimetric effects and timings of full online replanning as compared to the five p...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cureus
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5988167/ https://www.ncbi.nlm.nih.gov/pubmed/29876153 http://dx.doi.org/10.7759/cureus.2431 |
_version_ | 1783329242765852672 |
---|---|
author | Winkel, Dennis Bol, Gijsbert H Kiekebosch, Ilse H Van Asselen, Bram Kroon, Petra S Jürgenliemk-Schulz, Ina M Raaymakers, Bas W |
author_facet | Winkel, Dennis Bol, Gijsbert H Kiekebosch, Ilse H Van Asselen, Bram Kroon, Petra S Jürgenliemk-Schulz, Ina M Raaymakers, Bas W |
author_sort | Winkel, Dennis |
collection | PubMed |
description | The superior soft tissue contrast provided by magnetic resonance (MR) images on the 1.5T MR-linac allows for the incorporation of patient anatomy information. In this retrospective case study, we present the simulated dosimetric effects and timings of full online replanning as compared to the five plan adaptation methods currently available on the 1.5T MR-linac treatment system. For this case, it is possible to create treatment plans with all six methods within a time slot suitable for an online treatment procedure. However, large dosimetric differences between the plan adaptation methods and full online replanning are present with regards to target coverage and dose to organs at risk (OARs). |
format | Online Article Text |
id | pubmed-5988167 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Cureus |
record_format | MEDLINE/PubMed |
spelling | pubmed-59881672018-06-06 Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments Winkel, Dennis Bol, Gijsbert H Kiekebosch, Ilse H Van Asselen, Bram Kroon, Petra S Jürgenliemk-Schulz, Ina M Raaymakers, Bas W Cureus Medical Physics The superior soft tissue contrast provided by magnetic resonance (MR) images on the 1.5T MR-linac allows for the incorporation of patient anatomy information. In this retrospective case study, we present the simulated dosimetric effects and timings of full online replanning as compared to the five plan adaptation methods currently available on the 1.5T MR-linac treatment system. For this case, it is possible to create treatment plans with all six methods within a time slot suitable for an online treatment procedure. However, large dosimetric differences between the plan adaptation methods and full online replanning are present with regards to target coverage and dose to organs at risk (OARs). Cureus 2018-04-05 /pmc/articles/PMC5988167/ /pubmed/29876153 http://dx.doi.org/10.7759/cureus.2431 Text en Copyright © 2018, Winkel et al. http://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Medical Physics Winkel, Dennis Bol, Gijsbert H Kiekebosch, Ilse H Van Asselen, Bram Kroon, Petra S Jürgenliemk-Schulz, Ina M Raaymakers, Bas W Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title | Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title_full | Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title_fullStr | Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title_full_unstemmed | Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title_short | Evaluation of Online Plan Adaptation Strategies for the 1.5T MR-linac Based on “First-In-Man” Treatments |
title_sort | evaluation of online plan adaptation strategies for the 1.5t mr-linac based on “first-in-man” treatments |
topic | Medical Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5988167/ https://www.ncbi.nlm.nih.gov/pubmed/29876153 http://dx.doi.org/10.7759/cureus.2431 |
work_keys_str_mv | AT winkeldennis evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT bolgijsberth evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT kiekeboschilseh evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT vanasselenbram evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT kroonpetras evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT jurgenliemkschulzinam evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments AT raaymakersbasw evaluationofonlineplanadaptationstrategiesforthe15tmrlinacbasedonfirstinmantreatments |