Cargando…
Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer wit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989504/ https://www.ncbi.nlm.nih.gov/pubmed/29785990 http://dx.doi.org/10.4103/ijo.IJO_929_17 |
_version_ | 1783329478768852992 |
---|---|
author | Sharma, Namrata Singhal, Deepali Maharana, Prafulla Kumar Jain, Rahul Sahay, Pranita Titiyal, Jeewan S |
author_facet | Sharma, Namrata Singhal, Deepali Maharana, Prafulla Kumar Jain, Rahul Sahay, Pranita Titiyal, Jeewan S |
author_sort | Sharma, Namrata |
collection | PubMed |
description | PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer with plaque. METHODS: Seven eyes of seven patients presenting with VKC with shield ulcer with plaque were enrolled in this prospective case series and planned for shield ulcer debridement with ML AMT. Debridement of the ulcer base with double-layered AMT was done under the continuous guidance of iOCT. The main outcome measure was the time for complete reepithelialization. Statistical analysis was performed using the Stata-14.0 program for Windows. Data were presented as mean ± standard deviation/median (minimum-maximum) and frequency percentage as applicable. RESULTS: The surgery could be completed successfully in all cases and iOCT could provide real-time assessment of the depth of dissection during the entire procedure. The duration of complete healing and disintegration of amniotic membrane varied from 7 to 12 days. Recurrence was not seen in any case till 2 months follow-up. CONCLUSION: iOCT provides continuous monitoring of the depth of dissection and allows for a safe and complete debridement of the shield ulcer with plaque. |
format | Online Article Text |
id | pubmed-5989504 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-59895042018-06-15 Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation Sharma, Namrata Singhal, Deepali Maharana, Prafulla Kumar Jain, Rahul Sahay, Pranita Titiyal, Jeewan S Indian J Ophthalmol Original Article PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer with plaque. METHODS: Seven eyes of seven patients presenting with VKC with shield ulcer with plaque were enrolled in this prospective case series and planned for shield ulcer debridement with ML AMT. Debridement of the ulcer base with double-layered AMT was done under the continuous guidance of iOCT. The main outcome measure was the time for complete reepithelialization. Statistical analysis was performed using the Stata-14.0 program for Windows. Data were presented as mean ± standard deviation/median (minimum-maximum) and frequency percentage as applicable. RESULTS: The surgery could be completed successfully in all cases and iOCT could provide real-time assessment of the depth of dissection during the entire procedure. The duration of complete healing and disintegration of amniotic membrane varied from 7 to 12 days. Recurrence was not seen in any case till 2 months follow-up. CONCLUSION: iOCT provides continuous monitoring of the depth of dissection and allows for a safe and complete debridement of the shield ulcer with plaque. Medknow Publications & Media Pvt Ltd 2018-06 /pmc/articles/PMC5989504/ /pubmed/29785990 http://dx.doi.org/10.4103/ijo.IJO_929_17 Text en Copyright: © 2018 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Sharma, Namrata Singhal, Deepali Maharana, Prafulla Kumar Jain, Rahul Sahay, Pranita Titiyal, Jeewan S Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title | Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title_full | Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title_fullStr | Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title_full_unstemmed | Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title_short | Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
title_sort | continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989504/ https://www.ncbi.nlm.nih.gov/pubmed/29785990 http://dx.doi.org/10.4103/ijo.IJO_929_17 |
work_keys_str_mv | AT sharmanamrata continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation AT singhaldeepali continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation AT maharanaprafullakumar continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation AT jainrahul continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation AT sahaypranita continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation AT titiyaljeewans continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation |