Cargando…

Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation

PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Namrata, Singhal, Deepali, Maharana, Prafulla Kumar, Jain, Rahul, Sahay, Pranita, Titiyal, Jeewan S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989504/
https://www.ncbi.nlm.nih.gov/pubmed/29785990
http://dx.doi.org/10.4103/ijo.IJO_929_17
_version_ 1783329478768852992
author Sharma, Namrata
Singhal, Deepali
Maharana, Prafulla Kumar
Jain, Rahul
Sahay, Pranita
Titiyal, Jeewan S
author_facet Sharma, Namrata
Singhal, Deepali
Maharana, Prafulla Kumar
Jain, Rahul
Sahay, Pranita
Titiyal, Jeewan S
author_sort Sharma, Namrata
collection PubMed
description PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer with plaque. METHODS: Seven eyes of seven patients presenting with VKC with shield ulcer with plaque were enrolled in this prospective case series and planned for shield ulcer debridement with ML AMT. Debridement of the ulcer base with double-layered AMT was done under the continuous guidance of iOCT. The main outcome measure was the time for complete reepithelialization. Statistical analysis was performed using the Stata-14.0 program for Windows. Data were presented as mean ± standard deviation/median (minimum-maximum) and frequency percentage as applicable. RESULTS: The surgery could be completed successfully in all cases and iOCT could provide real-time assessment of the depth of dissection during the entire procedure. The duration of complete healing and disintegration of amniotic membrane varied from 7 to 12 days. Recurrence was not seen in any case till 2 months follow-up. CONCLUSION: iOCT provides continuous monitoring of the depth of dissection and allows for a safe and complete debridement of the shield ulcer with plaque.
format Online
Article
Text
id pubmed-5989504
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-59895042018-06-15 Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation Sharma, Namrata Singhal, Deepali Maharana, Prafulla Kumar Jain, Rahul Sahay, Pranita Titiyal, Jeewan S Indian J Ophthalmol Original Article PURPOSE: The aim of this study is to describe a modified surgical technique of continuous intraoperative optical coherence tomography (iOCT)-guided shield ulcer debridement with tuck-in multilayered Amniotic membrane transplantation (ML AMT) in vernal keratoconjunctivitis (VKC) with shield ulcer with plaque. METHODS: Seven eyes of seven patients presenting with VKC with shield ulcer with plaque were enrolled in this prospective case series and planned for shield ulcer debridement with ML AMT. Debridement of the ulcer base with double-layered AMT was done under the continuous guidance of iOCT. The main outcome measure was the time for complete reepithelialization. Statistical analysis was performed using the Stata-14.0 program for Windows. Data were presented as mean ± standard deviation/median (minimum-maximum) and frequency percentage as applicable. RESULTS: The surgery could be completed successfully in all cases and iOCT could provide real-time assessment of the depth of dissection during the entire procedure. The duration of complete healing and disintegration of amniotic membrane varied from 7 to 12 days. Recurrence was not seen in any case till 2 months follow-up. CONCLUSION: iOCT provides continuous monitoring of the depth of dissection and allows for a safe and complete debridement of the shield ulcer with plaque. Medknow Publications & Media Pvt Ltd 2018-06 /pmc/articles/PMC5989504/ /pubmed/29785990 http://dx.doi.org/10.4103/ijo.IJO_929_17 Text en Copyright: © 2018 Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sharma, Namrata
Singhal, Deepali
Maharana, Prafulla Kumar
Jain, Rahul
Sahay, Pranita
Titiyal, Jeewan S
Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title_full Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title_fullStr Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title_full_unstemmed Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title_short Continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
title_sort continuous intraoperative optical coherence tomography-guided shield ulcer debridement with tuck in multilayered amniotic membrane transplantation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5989504/
https://www.ncbi.nlm.nih.gov/pubmed/29785990
http://dx.doi.org/10.4103/ijo.IJO_929_17
work_keys_str_mv AT sharmanamrata continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation
AT singhaldeepali continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation
AT maharanaprafullakumar continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation
AT jainrahul continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation
AT sahaypranita continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation
AT titiyaljeewans continuousintraoperativeopticalcoherencetomographyguidedshieldulcerdebridementwithtuckinmultilayeredamnioticmembranetransplantation