Cargando…
Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients
PURPOSE: To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). METHODS: Two hundred cataract patients (200 eyes) with preoperative measurements by wid...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Ophthalmological Society
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990639/ https://www.ncbi.nlm.nih.gov/pubmed/29770639 http://dx.doi.org/10.3341/kjo.2017.0067 |
_version_ | 1783329618047008768 |
---|---|
author | Kim, Mingue Eom, Youngsub Song, Jong Suk Kim, Hyo Myung |
author_facet | Kim, Mingue Eom, Youngsub Song, Jong Suk Kim, Hyo Myung |
author_sort | Kim, Mingue |
collection | PubMed |
description | PURPOSE: To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). METHODS: Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation. RESULTS: Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = −0.509, p < 0.001) and SD-OCT SNR (rho = −0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors. CONCLUSIONS: Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts. |
format | Online Article Text |
id | pubmed-5990639 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Ophthalmological Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-59906392018-06-12 Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients Kim, Mingue Eom, Youngsub Song, Jong Suk Kim, Hyo Myung Korean J Ophthalmol Original Article PURPOSE: To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). METHODS: Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation. RESULTS: Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = −0.509, p < 0.001) and SD-OCT SNR (rho = −0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors. CONCLUSIONS: Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts. The Korean Ophthalmological Society 2018-06 2018-05-28 /pmc/articles/PMC5990639/ /pubmed/29770639 http://dx.doi.org/10.3341/kjo.2017.0067 Text en © 2018 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Mingue Eom, Youngsub Song, Jong Suk Kim, Hyo Myung Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title | Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title_full | Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title_fullStr | Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title_full_unstemmed | Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title_short | Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients |
title_sort | effect of cataract grade according to wide-field fundus images on measurement of macular thickness in cataract patients |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990639/ https://www.ncbi.nlm.nih.gov/pubmed/29770639 http://dx.doi.org/10.3341/kjo.2017.0067 |
work_keys_str_mv | AT kimmingue effectofcataractgradeaccordingtowidefieldfundusimagesonmeasurementofmacularthicknessincataractpatients AT eomyoungsub effectofcataractgradeaccordingtowidefieldfundusimagesonmeasurementofmacularthicknessincataractpatients AT songjongsuk effectofcataractgradeaccordingtowidefieldfundusimagesonmeasurementofmacularthicknessincataractpatients AT kimhyomyung effectofcataractgradeaccordingtowidefieldfundusimagesonmeasurementofmacularthicknessincataractpatients |