Cargando…

Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters

[Image: see text] Model coliphages (e.g., ΦX174, MS2, and PRD1) have been widely used as surrogates to study the fate and transport of pathogenic viruses in the environment and during wastewater treatment. Two groups of coliphages (F-specific and somatic) are being explored as indicators of viral fe...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Xiao, Lin, Xingyu, Urmann, Katharina, Li, Lijie, Xie, Xing, Jiang, Sunny, Hoffmann, Michael R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990930/
https://www.ncbi.nlm.nih.gov/pubmed/29738236
http://dx.doi.org/10.1021/acs.est.8b00241
_version_ 1783329702227738624
author Huang, Xiao
Lin, Xingyu
Urmann, Katharina
Li, Lijie
Xie, Xing
Jiang, Sunny
Hoffmann, Michael R.
author_facet Huang, Xiao
Lin, Xingyu
Urmann, Katharina
Li, Lijie
Xie, Xing
Jiang, Sunny
Hoffmann, Michael R.
author_sort Huang, Xiao
collection PubMed
description [Image: see text] Model coliphages (e.g., ΦX174, MS2, and PRD1) have been widely used as surrogates to study the fate and transport of pathogenic viruses in the environment and during wastewater treatment. Two groups of coliphages (F-specific and somatic) are being explored as indicators of viral fecal pollution in ambient water. However, the detection and quantification of coliphages still largely rely on time-consuming culture-based plaque assays. In this study, we developed an in-gel loop-mediated isothermal amplification (gLAMP) system enabling coliphage MS2 quantification within 30 min using standard laboratory devices. Viral particles (MS2) were immobilized with LAMP reagents in polyethylene glycol hydrogel, and then viral RNAs were amplified through a LAMP reaction. Due to the restriction effect of the hydrogel matrix, one viral particle would only produce one amplicon dot. Therefore, the sample virus concentrations can be determined based on the number of fluorescent amplicon dots using a smartphone for imaging. The method was validated by using artificially spiked and naturally contaminated water samples. gLAMP results were shown to correlate well with plaque assay counts (R(2) = 0.984, p < 0.05) and achieved similar sensitivity to quantitative reverse-transcription polymerase chain reaction (RT-qPCR; 1 plaque-forming unit per reaction). Moreover, gLAMP demonstrated a high level of tolerance against inhibitors naturally present in wastewater, in which RT-qPCR was completely inhibited. Besides MS2, gLAMP can also be used for the quantification of other microbial targets (e.g., Escherichia coli and Salmonella). Considering its simplicity, sensitivity, rapidity, and versatility, gLAMP holds great potential for microbial water-quality analysis, especially in resource-limited settings.
format Online
Article
Text
id pubmed-5990930
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-59909302018-06-08 Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters Huang, Xiao Lin, Xingyu Urmann, Katharina Li, Lijie Xie, Xing Jiang, Sunny Hoffmann, Michael R. Environ Sci Technol [Image: see text] Model coliphages (e.g., ΦX174, MS2, and PRD1) have been widely used as surrogates to study the fate and transport of pathogenic viruses in the environment and during wastewater treatment. Two groups of coliphages (F-specific and somatic) are being explored as indicators of viral fecal pollution in ambient water. However, the detection and quantification of coliphages still largely rely on time-consuming culture-based plaque assays. In this study, we developed an in-gel loop-mediated isothermal amplification (gLAMP) system enabling coliphage MS2 quantification within 30 min using standard laboratory devices. Viral particles (MS2) were immobilized with LAMP reagents in polyethylene glycol hydrogel, and then viral RNAs were amplified through a LAMP reaction. Due to the restriction effect of the hydrogel matrix, one viral particle would only produce one amplicon dot. Therefore, the sample virus concentrations can be determined based on the number of fluorescent amplicon dots using a smartphone for imaging. The method was validated by using artificially spiked and naturally contaminated water samples. gLAMP results were shown to correlate well with plaque assay counts (R(2) = 0.984, p < 0.05) and achieved similar sensitivity to quantitative reverse-transcription polymerase chain reaction (RT-qPCR; 1 plaque-forming unit per reaction). Moreover, gLAMP demonstrated a high level of tolerance against inhibitors naturally present in wastewater, in which RT-qPCR was completely inhibited. Besides MS2, gLAMP can also be used for the quantification of other microbial targets (e.g., Escherichia coli and Salmonella). Considering its simplicity, sensitivity, rapidity, and versatility, gLAMP holds great potential for microbial water-quality analysis, especially in resource-limited settings. American Chemical Society 2018-05-08 2018-06-05 /pmc/articles/PMC5990930/ /pubmed/29738236 http://dx.doi.org/10.1021/acs.est.8b00241 Text en Copyright © 2018 American Chemical Society This is an open access article published under a Creative Commons Attribution (CC-BY) License (http://pubs.acs.org/page/policy/authorchoice_ccby_termsofuse.html) , which permits unrestricted use, distribution and reproduction in any medium, provided the author and source are cited.
spellingShingle Huang, Xiao
Lin, Xingyu
Urmann, Katharina
Li, Lijie
Xie, Xing
Jiang, Sunny
Hoffmann, Michael R.
Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title_full Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title_fullStr Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title_full_unstemmed Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title_short Smartphone-Based in-Gel Loop-Mediated Isothermal Amplification (gLAMP) System Enables Rapid Coliphage MS2 Quantification in Environmental Waters
title_sort smartphone-based in-gel loop-mediated isothermal amplification (glamp) system enables rapid coliphage ms2 quantification in environmental waters
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5990930/
https://www.ncbi.nlm.nih.gov/pubmed/29738236
http://dx.doi.org/10.1021/acs.est.8b00241
work_keys_str_mv AT huangxiao smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT linxingyu smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT urmannkatharina smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT lilijie smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT xiexing smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT jiangsunny smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters
AT hoffmannmichaelr smartphonebasedingelloopmediatedisothermalamplificationglampsystemenablesrapidcoliphagems2quantificationinenvironmentalwaters