Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey

OBJECTIVE: To examine the prevalence and characteristics of medical device–related pressure injuries (MDR PIs) in a large, generalizable database. METHODS: This study is a retrospective analysis of the 2016 International Pressure Ulcer Prevalence data. Data were limited to US and Canadian facilities...

Descripción completa

Detalles Bibliográficos
Autores principales: Kayser, Susan A., VanGilder, Catherine A., Ayello, Elizabeth A., Lachenbruch, Charlie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991189/
https://www.ncbi.nlm.nih.gov/pubmed/29782417
http://dx.doi.org/10.1097/01.ASW.0000532475.11971.aa
_version_ 1783329752757567488
author Kayser, Susan A.
VanGilder, Catherine A.
Ayello, Elizabeth A.
Lachenbruch, Charlie
author_facet Kayser, Susan A.
VanGilder, Catherine A.
Ayello, Elizabeth A.
Lachenbruch, Charlie
author_sort Kayser, Susan A.
collection PubMed
description OBJECTIVE: To examine the prevalence and characteristics of medical device–related pressure injuries (MDR PIs) in a large, generalizable database. METHODS: This study is a retrospective analysis of the 2016 International Pressure Ulcer Prevalence data. Data were limited to US and Canadian facilities. Facilities included acute care, long-term care, rehabilitation, long-term acute care hospitals, and hospice. Analysis included 102,865 adult patients; 99,876 had complete data and were the focus of the analysis and are reported in the results below. RESULTS: The overall PI prevalence was 7.2% (n = 7189), and the facility-acquired prevalence was 3.1% (n = 3113). The prevalence of MDR PIs was 0.60% (n = 601), which included both mucosal and nonmucosal MDR PIs. In this study, 75% of MDR PIs were facility acquired, whereas non-MDR PIs were most commonly present on admission. Facility-acquired MDR PIs formed 3 days faster than facility-acquired non-MDR PIs (12 vs 15 days; P < .05). By stage, most MDR PIs were superficial (58% were Stage 1 or 2), 15% were deep-tissue PIs, and 22% were full-thickness PIs (Stage 3 or 4 or unstageable). The most common anatomic locations for MDR PIs were the ears (29%) and the feet (12%). The most common devices associated with MDR PIs were nasal oxygen tubes, 26%; other, 19%; cast/splints, 12%; and continuous positive airway pressure/bilevel positive airway pressure masks, 9%. CONCLUSIONS: Because MDR PIs form faster than non-MDR PIs, timely proactive assessment and prevention measures are critical. Most MDR PIs occurred at the face and head region, and the ears specifically. The most common devices linked with MDR PIs were oxygen tubing and masks, making assessment and prevention efforts critical for patients who require those devices.
format Online
Article
Text
id pubmed-5991189
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-59911892018-06-19 Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey Kayser, Susan A. VanGilder, Catherine A. Ayello, Elizabeth A. Lachenbruch, Charlie Adv Skin Wound Care Features: Original Investigations OBJECTIVE: To examine the prevalence and characteristics of medical device–related pressure injuries (MDR PIs) in a large, generalizable database. METHODS: This study is a retrospective analysis of the 2016 International Pressure Ulcer Prevalence data. Data were limited to US and Canadian facilities. Facilities included acute care, long-term care, rehabilitation, long-term acute care hospitals, and hospice. Analysis included 102,865 adult patients; 99,876 had complete data and were the focus of the analysis and are reported in the results below. RESULTS: The overall PI prevalence was 7.2% (n = 7189), and the facility-acquired prevalence was 3.1% (n = 3113). The prevalence of MDR PIs was 0.60% (n = 601), which included both mucosal and nonmucosal MDR PIs. In this study, 75% of MDR PIs were facility acquired, whereas non-MDR PIs were most commonly present on admission. Facility-acquired MDR PIs formed 3 days faster than facility-acquired non-MDR PIs (12 vs 15 days; P < .05). By stage, most MDR PIs were superficial (58% were Stage 1 or 2), 15% were deep-tissue PIs, and 22% were full-thickness PIs (Stage 3 or 4 or unstageable). The most common anatomic locations for MDR PIs were the ears (29%) and the feet (12%). The most common devices associated with MDR PIs were nasal oxygen tubes, 26%; other, 19%; cast/splints, 12%; and continuous positive airway pressure/bilevel positive airway pressure masks, 9%. CONCLUSIONS: Because MDR PIs form faster than non-MDR PIs, timely proactive assessment and prevention measures are critical. Most MDR PIs occurred at the face and head region, and the ears specifically. The most common devices linked with MDR PIs were oxygen tubing and masks, making assessment and prevention efforts critical for patients who require those devices. Lippincott Williams & Wilkins 2018-06 2018-05-22 /pmc/articles/PMC5991189/ /pubmed/29782417 http://dx.doi.org/10.1097/01.ASW.0000532475.11971.aa Text en Copyright © 2018 Wolters Kluwer Health, Inc. All rights reserved.
spellingShingle Features: Original Investigations
Kayser, Susan A.
VanGilder, Catherine A.
Ayello, Elizabeth A.
Lachenbruch, Charlie
Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title_full Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title_fullStr Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title_full_unstemmed Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title_short Prevalence and Analysis of Medical Device-Related Pressure Injuries: Results from the International Pressure Ulcer Prevalence Survey
title_sort prevalence and analysis of medical device-related pressure injuries: results from the international pressure ulcer prevalence survey
topic Features: Original Investigations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991189/
https://www.ncbi.nlm.nih.gov/pubmed/29782417
http://dx.doi.org/10.1097/01.ASW.0000532475.11971.aa
work_keys_str_mv AT kaysersusana prevalenceandanalysisofmedicaldevicerelatedpressureinjuriesresultsfromtheinternationalpressureulcerprevalencesurvey
AT vangildercatherinea prevalenceandanalysisofmedicaldevicerelatedpressureinjuriesresultsfromtheinternationalpressureulcerprevalencesurvey
AT ayelloelizabetha prevalenceandanalysisofmedicaldevicerelatedpressureinjuriesresultsfromtheinternationalpressureulcerprevalencesurvey
AT lachenbruchcharlie prevalenceandanalysisofmedicaldevicerelatedpressureinjuriesresultsfromtheinternationalpressureulcerprevalencesurvey