Cargando…

A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women

Prenatal detection of the fetal RHD status can be useful in the management of RhD incompatibility to identify fetuses at risk of hemolytic disease. Hemolytic disease causes morbidity and mortality of the fetus in the neonatal period. The routine use of antenatal and postnatal anti-D prophylaxis has...

Descripción completa

Detalles Bibliográficos
Autores principales: Dündar Yenilmez, Ebru, Kökbaş, Umut, Kartlaşmış, Kezban, Kayrın, Levent, Tuli, Abdullah
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991352/
https://www.ncbi.nlm.nih.gov/pubmed/29874251
http://dx.doi.org/10.1371/journal.pone.0197855
_version_ 1783329799949778944
author Dündar Yenilmez, Ebru
Kökbaş, Umut
Kartlaşmış, Kezban
Kayrın, Levent
Tuli, Abdullah
author_facet Dündar Yenilmez, Ebru
Kökbaş, Umut
Kartlaşmış, Kezban
Kayrın, Levent
Tuli, Abdullah
author_sort Dündar Yenilmez, Ebru
collection PubMed
description Prenatal detection of the fetal RHD status can be useful in the management of RhD incompatibility to identify fetuses at risk of hemolytic disease. Hemolytic disease causes morbidity and mortality of the fetus in the neonatal period. The routine use of antenatal and postnatal anti-D prophylaxis has reduced the incidence of hemolytic disease of the fetus and newborn. This study describe the detection of fetal RhD antigens in blood of RhD negative pregnant women using a nanopolymer coated electrochemical biosensor for medical diagnosis. Cell free fetal DNA in maternal plasma was also used to genotyping fetal RHD status using multiplex real-time PCR. Twenty-six RhD negative pregnant women in different gestational ages were included in the study. RhD positive fetal antibodies detected with a developed biosensor in maternal blood of RhD negative mothers. The electrochemical measurements were performed on a PalmSens potentiostat, and corundum ceramic based screen printed gold electrode combined with the reference Ag/AgCl electrode, and the auxiliary Au/Pd (98/2%) electrode. Fetal RHD genotyping performed using fluorescence-based multiplex real-time PCR exons 5 and 7 of the RHD gene. The fetal RHD status of 26 RhD negative cases were detected 21 as RhD positive and 5 as RhD negative with electrochemical biosensor. Fetal RHD status confirmed with extracted fetal DNA in maternal plasma using multiplex real-time PCR RHD genotyping and by serological test after delivery. The new method for fetal RhD detection in early pregnancy is useful and can be carry out rapidly in clinical diagnosis. Using automated biosensors are reproducible, quick and results can be generated within a few minutes compared to noninvasive fetal RHD genotyping from maternal plasma with real-time PCR-based techniques. We suggest the biosensor techniques could become an alternative part of fetal RHD genotyping from maternal plasma as a prenatal screening in the management of RhD incompatibility.
format Online
Article
Text
id pubmed-5991352
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-59913522018-06-08 A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women Dündar Yenilmez, Ebru Kökbaş, Umut Kartlaşmış, Kezban Kayrın, Levent Tuli, Abdullah PLoS One Research Article Prenatal detection of the fetal RHD status can be useful in the management of RhD incompatibility to identify fetuses at risk of hemolytic disease. Hemolytic disease causes morbidity and mortality of the fetus in the neonatal period. The routine use of antenatal and postnatal anti-D prophylaxis has reduced the incidence of hemolytic disease of the fetus and newborn. This study describe the detection of fetal RhD antigens in blood of RhD negative pregnant women using a nanopolymer coated electrochemical biosensor for medical diagnosis. Cell free fetal DNA in maternal plasma was also used to genotyping fetal RHD status using multiplex real-time PCR. Twenty-six RhD negative pregnant women in different gestational ages were included in the study. RhD positive fetal antibodies detected with a developed biosensor in maternal blood of RhD negative mothers. The electrochemical measurements were performed on a PalmSens potentiostat, and corundum ceramic based screen printed gold electrode combined with the reference Ag/AgCl electrode, and the auxiliary Au/Pd (98/2%) electrode. Fetal RHD genotyping performed using fluorescence-based multiplex real-time PCR exons 5 and 7 of the RHD gene. The fetal RHD status of 26 RhD negative cases were detected 21 as RhD positive and 5 as RhD negative with electrochemical biosensor. Fetal RHD status confirmed with extracted fetal DNA in maternal plasma using multiplex real-time PCR RHD genotyping and by serological test after delivery. The new method for fetal RhD detection in early pregnancy is useful and can be carry out rapidly in clinical diagnosis. Using automated biosensors are reproducible, quick and results can be generated within a few minutes compared to noninvasive fetal RHD genotyping from maternal plasma with real-time PCR-based techniques. We suggest the biosensor techniques could become an alternative part of fetal RHD genotyping from maternal plasma as a prenatal screening in the management of RhD incompatibility. Public Library of Science 2018-06-06 /pmc/articles/PMC5991352/ /pubmed/29874251 http://dx.doi.org/10.1371/journal.pone.0197855 Text en © 2018 DuÈndar Yenilmez et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Dündar Yenilmez, Ebru
Kökbaş, Umut
Kartlaşmış, Kezban
Kayrın, Levent
Tuli, Abdullah
A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title_full A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title_fullStr A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title_full_unstemmed A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title_short A new biosensor for noninvasive determination of fetal RHD status in maternal blood of RhD negative pregnant women
title_sort new biosensor for noninvasive determination of fetal rhd status in maternal blood of rhd negative pregnant women
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991352/
https://www.ncbi.nlm.nih.gov/pubmed/29874251
http://dx.doi.org/10.1371/journal.pone.0197855
work_keys_str_mv AT dundaryenilmezebru anewbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kokbasumut anewbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kartlasmıskezban anewbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kayrınlevent anewbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT tuliabdullah anewbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT dundaryenilmezebru newbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kokbasumut newbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kartlasmıskezban newbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT kayrınlevent newbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen
AT tuliabdullah newbiosensorfornoninvasivedeterminationoffetalrhdstatusinmaternalbloodofrhdnegativepregnantwomen