A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy

Conventional radiological and endoscopic techniques utilizing long tubes were ineffective in visualizing the small bowel mucosa until the development of wireless capsule endoscopy (WCE). WCE is a revolutionary endoscopic technology that can diagnose the complete gastrointestinal tract. However, the...

Descripción completa

Detalles Bibliográficos
Formato: Online Artículo Texto
Lenguaje:English
Publicado: IEEE 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991866/
https://www.ncbi.nlm.nih.gov/pubmed/29888143
http://dx.doi.org/10.1109/JTEHM.2018.2837895
_version_ 1783329921448280064
collection PubMed
description Conventional radiological and endoscopic techniques utilizing long tubes were ineffective in visualizing the small bowel mucosa until the development of wireless capsule endoscopy (WCE). WCE is a revolutionary endoscopic technology that can diagnose the complete gastrointestinal tract. However, the existing capsule technologies are passive, and thus they cannot be navigated to or held in a specific location. The design of an active capsule will present the opportunity to move and stop a device at any targeted locations leading to numerous medical applications such as drug delivery or collecting tissue samples for examinations in the laboratory. This paper implements a new locomotion methodology for WCE systems using an electromagnetic platform. The platform produces a dynamic electromagnetic field to control the motion of the capsule. The strength and the direction of the electromagnetic field that is generated by the platform are continuously adjusted in order to maintain the equilibrium state during the capsule movement. We present the detailed design of the proposed platform with an experimental setup with polyvinyl chloride tubes and ex vivo to demonstrate the performance of the capsule motion.
format Online
Article
Text
id pubmed-5991866
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher IEEE
record_format MEDLINE/PubMed
spelling pubmed-59918662018-06-10 A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy IEEE J Transl Eng Health Med Article Conventional radiological and endoscopic techniques utilizing long tubes were ineffective in visualizing the small bowel mucosa until the development of wireless capsule endoscopy (WCE). WCE is a revolutionary endoscopic technology that can diagnose the complete gastrointestinal tract. However, the existing capsule technologies are passive, and thus they cannot be navigated to or held in a specific location. The design of an active capsule will present the opportunity to move and stop a device at any targeted locations leading to numerous medical applications such as drug delivery or collecting tissue samples for examinations in the laboratory. This paper implements a new locomotion methodology for WCE systems using an electromagnetic platform. The platform produces a dynamic electromagnetic field to control the motion of the capsule. The strength and the direction of the electromagnetic field that is generated by the platform are continuously adjusted in order to maintain the equilibrium state during the capsule movement. We present the detailed design of the proposed platform with an experimental setup with polyvinyl chloride tubes and ex vivo to demonstrate the performance of the capsule motion. IEEE 2018-05-21 /pmc/articles/PMC5991866/ /pubmed/29888143 http://dx.doi.org/10.1109/JTEHM.2018.2837895 Text en 2168-2372 © 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission. See http://www.ieee.org/publications_standards/publications/rights/index.html for more information.
spellingShingle Article
A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title_full A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title_fullStr A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title_full_unstemmed A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title_short A Locomotion Control Platform With Dynamic Electromagnetic Field for Active Capsule Endoscopy
title_sort locomotion control platform with dynamic electromagnetic field for active capsule endoscopy
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5991866/
https://www.ncbi.nlm.nih.gov/pubmed/29888143
http://dx.doi.org/10.1109/JTEHM.2018.2837895
work_keys_str_mv AT alocomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy
AT alocomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy
AT alocomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy
AT locomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy
AT locomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy
AT locomotioncontrolplatformwithdynamicelectromagneticfieldforactivecapsuleendoscopy