Cargando…

Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases

BACKGROUND: This study aimed to evaluate the overall accuracy of the beam commissioning criteria of targeted image-guided radiation therapy (TiGRT) treatment planning system (TPS) based on the American Association of Physicists in Medicine (AAPM) Task Group Report 119 (TG-119). METHODS: The work was...

Descripción completa

Detalles Bibliográficos
Autores principales: Saeb, Mohsen, Shahbazi-Gahrouei, Daryoush, Monadi, Shahram
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5992903/
https://www.ncbi.nlm.nih.gov/pubmed/29928634
_version_ 1783330129874780160
author Saeb, Mohsen
Shahbazi-Gahrouei, Daryoush
Monadi, Shahram
author_facet Saeb, Mohsen
Shahbazi-Gahrouei, Daryoush
Monadi, Shahram
author_sort Saeb, Mohsen
collection PubMed
description BACKGROUND: This study aimed to evaluate the overall accuracy of the beam commissioning criteria of targeted image-guided radiation therapy (TiGRT) treatment planning system (TPS) based on the American Association of Physicists in Medicine (AAPM) Task Group Report 119 (TG-119). METHODS: The work was performed using 6 MV energy LINAC with a variable dose rate of 200 MU/min which equipped with the high-quality external TiGRT dynamic multileaf collimator model H. The AAPM TG-119 intensity-modulated radiation therapy (IMRT) commissioning tests are composed of two preliminary tests and four clinical test cases. The clinical tests consisted of mock prostate, mock head and neck, C-shaped target, and multitarget. EDR2 film was used for evaluating the IMRT plans and point dose measured by a Pinpoint chamber positioned in slab phantom. The film analysis was done with the Sun Nuclear Corporation patient software. The dose prescription for each fraction was 200 cGy in mock prostate, mock head and neck, C-shaped target, and multitarget. Dose distributions were analyzed using gamma criteria of 3% and 2% dose difference (DD) and 3 and 2 mm distance to agreement. RESULTS: In all test cases, the gamma criteria for 2%/2 and 3%/3 were found to be 94% and 98%, respectively. Results showed that the average gamma criteria result was in the range of 99.1% to 93% (3%/3, 2%/2) overall test cases. CONCLUSIONS: Findings were favorable and in some tests were comparable with the other studies. The dose point values were within the mean values of the range reported by TG-119. Overall, the TiGRT TPS is needed to apply IMRT technique in radiation therapy centers.
format Online
Article
Text
id pubmed-5992903
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-59929032018-06-20 Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases Saeb, Mohsen Shahbazi-Gahrouei, Daryoush Monadi, Shahram J Med Signals Sens Original Article BACKGROUND: This study aimed to evaluate the overall accuracy of the beam commissioning criteria of targeted image-guided radiation therapy (TiGRT) treatment planning system (TPS) based on the American Association of Physicists in Medicine (AAPM) Task Group Report 119 (TG-119). METHODS: The work was performed using 6 MV energy LINAC with a variable dose rate of 200 MU/min which equipped with the high-quality external TiGRT dynamic multileaf collimator model H. The AAPM TG-119 intensity-modulated radiation therapy (IMRT) commissioning tests are composed of two preliminary tests and four clinical test cases. The clinical tests consisted of mock prostate, mock head and neck, C-shaped target, and multitarget. EDR2 film was used for evaluating the IMRT plans and point dose measured by a Pinpoint chamber positioned in slab phantom. The film analysis was done with the Sun Nuclear Corporation patient software. The dose prescription for each fraction was 200 cGy in mock prostate, mock head and neck, C-shaped target, and multitarget. Dose distributions were analyzed using gamma criteria of 3% and 2% dose difference (DD) and 3 and 2 mm distance to agreement. RESULTS: In all test cases, the gamma criteria for 2%/2 and 3%/3 were found to be 94% and 98%, respectively. Results showed that the average gamma criteria result was in the range of 99.1% to 93% (3%/3, 2%/2) overall test cases. CONCLUSIONS: Findings were favorable and in some tests were comparable with the other studies. The dose point values were within the mean values of the range reported by TG-119. Overall, the TiGRT TPS is needed to apply IMRT technique in radiation therapy centers. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5992903/ /pubmed/29928634 Text en Copyright: © 2018 Journal of Medical Signals & Sensors http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Saeb, Mohsen
Shahbazi-Gahrouei, Daryoush
Monadi, Shahram
Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title_full Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title_fullStr Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title_full_unstemmed Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title_short Evaluation of Targeted Image-Guided Radiation Therapy Treatment Planning System by Use of American Association of Physicists in Medicine Task Group-119 Test Cases
title_sort evaluation of targeted image-guided radiation therapy treatment planning system by use of american association of physicists in medicine task group-119 test cases
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5992903/
https://www.ncbi.nlm.nih.gov/pubmed/29928634
work_keys_str_mv AT saebmohsen evaluationoftargetedimageguidedradiationtherapytreatmentplanningsystembyuseofamericanassociationofphysicistsinmedicinetaskgroup119testcases
AT shahbazigahroueidaryoush evaluationoftargetedimageguidedradiationtherapytreatmentplanningsystembyuseofamericanassociationofphysicistsinmedicinetaskgroup119testcases
AT monadishahram evaluationoftargetedimageguidedradiationtherapytreatmentplanningsystembyuseofamericanassociationofphysicistsinmedicinetaskgroup119testcases