Cargando…
Custom-Made Direct Metal Laser Sintering Titanium Subperiosteal Implants: A Retrospective Clinical Study on 70 Patients
PURPOSE: To present a digital technique for the fabrication of custom-made subperiosteal implants and to report on the survival and complication rates encountered when using these fixtures. METHODS: The data used for this retrospective clinical study were derived from the medical records of five dif...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5994585/ https://www.ncbi.nlm.nih.gov/pubmed/29998133 http://dx.doi.org/10.1155/2018/5420391 |
Sumario: | PURPOSE: To present a digital technique for the fabrication of custom-made subperiosteal implants and to report on the survival and complication rates encountered when using these fixtures. METHODS: The data used for this retrospective clinical study were derived from the medical records of five different private dental practices. Inclusion criteria were patients over the age of 60, treated with custom-made direct metal laser sintering (DMLS) titanium subperiosteal implants (Eagle-Grid®, BTK, Dueville, Vicenza) during a two-year period (2014-2015) and restored with fixed restorations; all enrolled patients needed to have complete pre- and postoperative clinical and radiographic documentation, with at least 2 years of follow-up. Exclusion criteria were smoking and bruxism. The main outcomes looked at were implant survival and complications. RESULTS: Seventy patients (39 males and 31 females, aged 62-79 years) who had been treated with custom-made DMLS titanium subperiosteal implants were enrolled in this study. After 2 years of follow-up, three implants were lost due to recurrent, untreatable infections; the survival rate was therefore 95.8% (67/70 implants). Four patients reported pain/discomfort/swelling after implant placement; the incidence of immediate postoperative complications was therefore 5.7% (4/70 implants). During the follow-up period, one patient suffered from recurrent infections classified as a biologic complication; the incidence of biologic complications was therefore 1.4% (1/67 surviving implants). Finally, four patients experienced prosthetic problems with their implant-supported restorations during the provisional phase (fracture of the acrylic restoration) and two patients had ceramic chipping of the definitive restoration; the incidence of prosthetic complications was therefore 8.9% (6/67 surviving implants). CONCLUSIONS: Within the limits of the present study (limited follow-up time and low number of patients treated, retrospective design), the application of custom-made DMLS titanium subperiosteal implants showed satisfactory implant survival (95.8%) and low complication rates. Further studies are needed to confirm the positive outcomes found in this research. |
---|