Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques
This study aimed to evaluate whether a prototype echo planar imaging sequence with integrated-shimming (iShim-EPI) can improve image quality in the thyroid gland in comparison to 3D-volume shimming echo planar imaging (3D-Shim-EPI), and to compare ADC values derived from iShim-EPI with those of 3D-S...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Impact Journals LLC
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995232/ https://www.ncbi.nlm.nih.gov/pubmed/29899853 http://dx.doi.org/10.18632/oncotarget.25279 |
_version_ | 1783330576820862976 |
---|---|
author | Chen, Luguang Sun, Peipei Hao, Qiang Yin, Wei Xu, Bing Ma, Chao Stemmer, Alto Fu, Caixia Wang, Minjie Lu, Jianping |
author_facet | Chen, Luguang Sun, Peipei Hao, Qiang Yin, Wei Xu, Bing Ma, Chao Stemmer, Alto Fu, Caixia Wang, Minjie Lu, Jianping |
author_sort | Chen, Luguang |
collection | PubMed |
description | This study aimed to evaluate whether a prototype echo planar imaging sequence with integrated-shimming (iShim-EPI) can improve image quality in the thyroid gland in comparison to 3D-volume shimming echo planar imaging (3D-Shim-EPI), and to compare ADC values derived from iShim-EPI with those of 3D-Shim-EPI. Twenty-one patients with thyroid disease were enrolled and underwent axial DWIs with iShim-EPI and 3D-Shim-EPI using a 3 Tesla magnetic resonance scanner in this prospective study. Both sets of DWI images were evaluated by two independent observers who identified susceptibility and ghost artifacts and evaluated the images' capacity to detect thyroid nodules using quantitative scores. The ADC values of the thyroid nodules and the normal thyroid gland were measured two times within a 4-week period. The reproducibility was evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman plots. There were significant differences in the image quality scores for susceptibility (2.81 ± 0.37 vs. 1.93 ± 0.29, p < 0.001), ghost artifacts (2.95 ± 0.15 vs. 1.93 ± 0.29, p < 0.001) and the detectability of thyroid nodules (3.00 ± 0.00 vs. 2.55 ± 0.75, p = 0.008) between the iShim-EPI and 3D-Shim-EPI techniques, except for the ADC values of the thyroid nodules (1.607 ± 0.466×10(−3) mm(2)/s vs. 1.561 ± 0.483 × 10(−3) mm(2)/s, p = 0.184) and contralateral normal thyroid gland (1.295 ± 0.340 × 10(−3) mm(2)/s vs.1.279 ± 0.411 × 10(−3) mm(2)/s, p = 0.777). Both techniques demonstrated excellent agreement between the ADC values using the ICC (range, 0.963 to 0.999) and Bland-Altman plots. The iShim-EPI technique demonstrated significantly higher image quality compared with the conventional 3D-Shim-EPI technique, with no significant differences in the ADC values. |
format | Online Article Text |
id | pubmed-5995232 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Impact Journals LLC |
record_format | MEDLINE/PubMed |
spelling | pubmed-59952322018-06-13 Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques Chen, Luguang Sun, Peipei Hao, Qiang Yin, Wei Xu, Bing Ma, Chao Stemmer, Alto Fu, Caixia Wang, Minjie Lu, Jianping Oncotarget Clinical Research Paper This study aimed to evaluate whether a prototype echo planar imaging sequence with integrated-shimming (iShim-EPI) can improve image quality in the thyroid gland in comparison to 3D-volume shimming echo planar imaging (3D-Shim-EPI), and to compare ADC values derived from iShim-EPI with those of 3D-Shim-EPI. Twenty-one patients with thyroid disease were enrolled and underwent axial DWIs with iShim-EPI and 3D-Shim-EPI using a 3 Tesla magnetic resonance scanner in this prospective study. Both sets of DWI images were evaluated by two independent observers who identified susceptibility and ghost artifacts and evaluated the images' capacity to detect thyroid nodules using quantitative scores. The ADC values of the thyroid nodules and the normal thyroid gland were measured two times within a 4-week period. The reproducibility was evaluated using the intraclass correlation coefficient (ICC) and Bland-Altman plots. There were significant differences in the image quality scores for susceptibility (2.81 ± 0.37 vs. 1.93 ± 0.29, p < 0.001), ghost artifacts (2.95 ± 0.15 vs. 1.93 ± 0.29, p < 0.001) and the detectability of thyroid nodules (3.00 ± 0.00 vs. 2.55 ± 0.75, p = 0.008) between the iShim-EPI and 3D-Shim-EPI techniques, except for the ADC values of the thyroid nodules (1.607 ± 0.466×10(−3) mm(2)/s vs. 1.561 ± 0.483 × 10(−3) mm(2)/s, p = 0.184) and contralateral normal thyroid gland (1.295 ± 0.340 × 10(−3) mm(2)/s vs.1.279 ± 0.411 × 10(−3) mm(2)/s, p = 0.777). Both techniques demonstrated excellent agreement between the ADC values using the ICC (range, 0.963 to 0.999) and Bland-Altman plots. The iShim-EPI technique demonstrated significantly higher image quality compared with the conventional 3D-Shim-EPI technique, with no significant differences in the ADC values. Impact Journals LLC 2018-05-25 /pmc/articles/PMC5995232/ /pubmed/29899853 http://dx.doi.org/10.18632/oncotarget.25279 Text en Copyright: © 2018 Chen et al. http://creativecommons.org/licenses/by/3.0/ This article is distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0/) (CC-BY), which permits unrestricted use and redistribution provided that the original author and source are credited. |
spellingShingle | Clinical Research Paper Chen, Luguang Sun, Peipei Hao, Qiang Yin, Wei Xu, Bing Ma, Chao Stemmer, Alto Fu, Caixia Wang, Minjie Lu, Jianping Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title | Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title_full | Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title_fullStr | Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title_full_unstemmed | Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title_short | Diffusion-weighted MRI in the evaluation of the thyroid nodule: Comparison between integrated-shimming EPI and conventional 3D-shimming EPI techniques |
title_sort | diffusion-weighted mri in the evaluation of the thyroid nodule: comparison between integrated-shimming epi and conventional 3d-shimming epi techniques |
topic | Clinical Research Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995232/ https://www.ncbi.nlm.nih.gov/pubmed/29899853 http://dx.doi.org/10.18632/oncotarget.25279 |
work_keys_str_mv | AT chenluguang diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT sunpeipei diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT haoqiang diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT yinwei diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT xubing diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT machao diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT stemmeralto diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT fucaixia diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT wangminjie diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques AT lujianping diffusionweightedmriintheevaluationofthethyroidnodulecomparisonbetweenintegratedshimmingepiandconventional3dshimmingepitechniques |