Cargando…
High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser
PURPOSE: To present refractive outcomes from consecutive cases with the Alcon Wavelight(®) EX500 excimer laser using photorefractive keratectomy (PRK) in patients with high myopia. METHODS: A retrospective chart review of consecutive cases of high myopic eyes (≥6.0 Diopters [D]) undergoing PRK with...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995275/ https://www.ncbi.nlm.nih.gov/pubmed/29922033 http://dx.doi.org/10.2147/OPTH.S164110 |
_version_ | 1783330586761363456 |
---|---|
author | Mifflin, Mark D Betts, Brent S Nguyen, Jason Pouly, Severin |
author_facet | Mifflin, Mark D Betts, Brent S Nguyen, Jason Pouly, Severin |
author_sort | Mifflin, Mark D |
collection | PubMed |
description | PURPOSE: To present refractive outcomes from consecutive cases with the Alcon Wavelight(®) EX500 excimer laser using photorefractive keratectomy (PRK) in patients with high myopia. METHODS: A retrospective chart review of consecutive cases of high myopic eyes (≥6.0 Diopters [D]) undergoing PRK with the Alcon Wavelight EX500 excimer laser (Alcon Laboratories, Fort Worth, TX, USA) was done. Moderately high myopic eyes (6.0 to <8.0 D [6 D]) were compared with high myopic eyes (8.0 D or greater [8 D]). Outcomes measured included pre- and postoperative refractive error, uncorrected distance visual acuity (UDVA), corrected distance visual acuity, spherical equivalent correction (SEQ), haze incidence, and intraocular pressure (IOP). RESULTS: One hundred eighteen eyes of 63 patients were evaluated, with 59 eyes having 12 months of follow-up. Thirty-one eyes of 19 patients had 8.0 D or more of myopia. Twelvemonth average LogMAR UDVA was −0.06 (20/17) for the 6 D group and −0.08 (20/16) for the 8 D group. Average 12-month SEQ was −0.18 D and preoperatively was −7.52 D for the 6 D group and −0.09 and −9.02 in the 8 D group. Sixty-five eyes (86%) and 24 eyes (96%) had an SEQ within 0.50 D of emmetropia at 3 months in the 6 and 8 D groups, respectively. One eye had visually significant haze developed at 8 months. Three eyes had IOP elevation that resolved with addition of short-term topical IOP-lowering medication. CONCLUSION: High myopic PRK with the Alcon Wavelight EX500 excimer laser yields excellent refractive outcomes with a low incidence of complications. |
format | Online Article Text |
id | pubmed-5995275 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-59952752018-06-19 High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser Mifflin, Mark D Betts, Brent S Nguyen, Jason Pouly, Severin Clin Ophthalmol Original Research PURPOSE: To present refractive outcomes from consecutive cases with the Alcon Wavelight(®) EX500 excimer laser using photorefractive keratectomy (PRK) in patients with high myopia. METHODS: A retrospective chart review of consecutive cases of high myopic eyes (≥6.0 Diopters [D]) undergoing PRK with the Alcon Wavelight EX500 excimer laser (Alcon Laboratories, Fort Worth, TX, USA) was done. Moderately high myopic eyes (6.0 to <8.0 D [6 D]) were compared with high myopic eyes (8.0 D or greater [8 D]). Outcomes measured included pre- and postoperative refractive error, uncorrected distance visual acuity (UDVA), corrected distance visual acuity, spherical equivalent correction (SEQ), haze incidence, and intraocular pressure (IOP). RESULTS: One hundred eighteen eyes of 63 patients were evaluated, with 59 eyes having 12 months of follow-up. Thirty-one eyes of 19 patients had 8.0 D or more of myopia. Twelvemonth average LogMAR UDVA was −0.06 (20/17) for the 6 D group and −0.08 (20/16) for the 8 D group. Average 12-month SEQ was −0.18 D and preoperatively was −7.52 D for the 6 D group and −0.09 and −9.02 in the 8 D group. Sixty-five eyes (86%) and 24 eyes (96%) had an SEQ within 0.50 D of emmetropia at 3 months in the 6 and 8 D groups, respectively. One eye had visually significant haze developed at 8 months. Three eyes had IOP elevation that resolved with addition of short-term topical IOP-lowering medication. CONCLUSION: High myopic PRK with the Alcon Wavelight EX500 excimer laser yields excellent refractive outcomes with a low incidence of complications. Dove Medical Press 2018-06-06 /pmc/articles/PMC5995275/ /pubmed/29922033 http://dx.doi.org/10.2147/OPTH.S164110 Text en © 2018 Mifflin et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Mifflin, Mark D Betts, Brent S Nguyen, Jason Pouly, Severin High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title | High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title_full | High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title_fullStr | High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title_full_unstemmed | High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title_short | High myopic photorefractive keratectomy outcomes with the Alcon Wavelight(®) EX500 excimer laser |
title_sort | high myopic photorefractive keratectomy outcomes with the alcon wavelight(®) ex500 excimer laser |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995275/ https://www.ncbi.nlm.nih.gov/pubmed/29922033 http://dx.doi.org/10.2147/OPTH.S164110 |
work_keys_str_mv | AT mifflinmarkd highmyopicphotorefractivekeratectomyoutcomeswiththealconwavelightex500excimerlaser AT bettsbrents highmyopicphotorefractivekeratectomyoutcomeswiththealconwavelightex500excimerlaser AT nguyenjason highmyopicphotorefractivekeratectomyoutcomeswiththealconwavelightex500excimerlaser AT poulyseverin highmyopicphotorefractivekeratectomyoutcomeswiththealconwavelightex500excimerlaser |