Cargando…
Technology and the Glaucoma Suspect
PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Fort...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995486/ https://www.ncbi.nlm.nih.gov/pubmed/27409509 http://dx.doi.org/10.1167/iovs.15-18931 |
_version_ | 1783330631556530176 |
---|---|
author | Blumberg, Dana M. De Moraes, Carlos Gustavo Liebmann, Jeffrey M. Garg, Reena Chen, Cynthia Theventhiran, Alex Hood, Donald C. |
author_facet | Blumberg, Dana M. De Moraes, Carlos Gustavo Liebmann, Jeffrey M. Garg, Reena Chen, Cynthia Theventhiran, Alex Hood, Donald C. |
author_sort | Blumberg, Dana M. |
collection | PubMed |
description | PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Forty-six eyes (46 patients) with suspicious optic nerves had previously undergone SD-OCT scans, 24-2 visual fields (VFs), and optic disc photographs. The average VF mean deviation was −1.97 ± 2.09 (SD) dB. Four glaucoma specialists examined the 138 individual diagnostic tests and classified the patient as likely glaucomatous or nonglaucomatous based on the results of a single test. The diagnostic performances of each of the three tests were compared to a previously determined reference standard, based on the consensus of a separate panel of four glaucoma specialists who examined all three tests together. RESULTS: Among the four specialists, the interobserver agreement across the three diagnostic tests was poor for VF and photos, with kappa (κ) values of 0.13 and 0.16, respectively, and moderate for OCT, with κ value of 0.40. Using panel consensus as reference standard, OCT had the highest discriminative ability, with an area under the curve (AUC) of 0.99 (95% 0.96–1.0) compared to photograph AUC 0.85 (95% 0.73–0.96) and VF AUC 0.86 (95% 0.76–0.96), suggestive of closer performance to that of a group of glaucoma specialists. CONCLUSIONS: Compared to VF and disc photography, SD-OCT, when used alone, had better internal agreement as well as better agreement with the consensus of clinicians using all available data. Future studies should evaluate best practices for SD-OCT interpretation. |
format | Online Article Text |
id | pubmed-5995486 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-59954862018-06-12 Technology and the Glaucoma Suspect Blumberg, Dana M. De Moraes, Carlos Gustavo Liebmann, Jeffrey M. Garg, Reena Chen, Cynthia Theventhiran, Alex Hood, Donald C. Invest Ophthalmol Vis Sci Articles PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Forty-six eyes (46 patients) with suspicious optic nerves had previously undergone SD-OCT scans, 24-2 visual fields (VFs), and optic disc photographs. The average VF mean deviation was −1.97 ± 2.09 (SD) dB. Four glaucoma specialists examined the 138 individual diagnostic tests and classified the patient as likely glaucomatous or nonglaucomatous based on the results of a single test. The diagnostic performances of each of the three tests were compared to a previously determined reference standard, based on the consensus of a separate panel of four glaucoma specialists who examined all three tests together. RESULTS: Among the four specialists, the interobserver agreement across the three diagnostic tests was poor for VF and photos, with kappa (κ) values of 0.13 and 0.16, respectively, and moderate for OCT, with κ value of 0.40. Using panel consensus as reference standard, OCT had the highest discriminative ability, with an area under the curve (AUC) of 0.99 (95% 0.96–1.0) compared to photograph AUC 0.85 (95% 0.73–0.96) and VF AUC 0.86 (95% 0.76–0.96), suggestive of closer performance to that of a group of glaucoma specialists. CONCLUSIONS: Compared to VF and disc photography, SD-OCT, when used alone, had better internal agreement as well as better agreement with the consensus of clinicians using all available data. Future studies should evaluate best practices for SD-OCT interpretation. The Association for Research in Vision and Ophthalmology 2016-07 /pmc/articles/PMC5995486/ /pubmed/27409509 http://dx.doi.org/10.1167/iovs.15-18931 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Articles Blumberg, Dana M. De Moraes, Carlos Gustavo Liebmann, Jeffrey M. Garg, Reena Chen, Cynthia Theventhiran, Alex Hood, Donald C. Technology and the Glaucoma Suspect |
title | Technology and the Glaucoma Suspect |
title_full | Technology and the Glaucoma Suspect |
title_fullStr | Technology and the Glaucoma Suspect |
title_full_unstemmed | Technology and the Glaucoma Suspect |
title_short | Technology and the Glaucoma Suspect |
title_sort | technology and the glaucoma suspect |
topic | Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995486/ https://www.ncbi.nlm.nih.gov/pubmed/27409509 http://dx.doi.org/10.1167/iovs.15-18931 |
work_keys_str_mv | AT blumbergdanam technologyandtheglaucomasuspect AT demoraescarlosgustavo technologyandtheglaucomasuspect AT liebmannjeffreym technologyandtheglaucomasuspect AT gargreena technologyandtheglaucomasuspect AT chencynthia technologyandtheglaucomasuspect AT theventhiranalex technologyandtheglaucomasuspect AT hooddonaldc technologyandtheglaucomasuspect |