Cargando…

Technology and the Glaucoma Suspect

PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Fort...

Descripción completa

Detalles Bibliográficos
Autores principales: Blumberg, Dana M., De Moraes, Carlos Gustavo, Liebmann, Jeffrey M., Garg, Reena, Chen, Cynthia, Theventhiran, Alex, Hood, Donald C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995486/
https://www.ncbi.nlm.nih.gov/pubmed/27409509
http://dx.doi.org/10.1167/iovs.15-18931
_version_ 1783330631556530176
author Blumberg, Dana M.
De Moraes, Carlos Gustavo
Liebmann, Jeffrey M.
Garg, Reena
Chen, Cynthia
Theventhiran, Alex
Hood, Donald C.
author_facet Blumberg, Dana M.
De Moraes, Carlos Gustavo
Liebmann, Jeffrey M.
Garg, Reena
Chen, Cynthia
Theventhiran, Alex
Hood, Donald C.
author_sort Blumberg, Dana M.
collection PubMed
description PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Forty-six eyes (46 patients) with suspicious optic nerves had previously undergone SD-OCT scans, 24-2 visual fields (VFs), and optic disc photographs. The average VF mean deviation was −1.97 ± 2.09 (SD) dB. Four glaucoma specialists examined the 138 individual diagnostic tests and classified the patient as likely glaucomatous or nonglaucomatous based on the results of a single test. The diagnostic performances of each of the three tests were compared to a previously determined reference standard, based on the consensus of a separate panel of four glaucoma specialists who examined all three tests together. RESULTS: Among the four specialists, the interobserver agreement across the three diagnostic tests was poor for VF and photos, with kappa (κ) values of 0.13 and 0.16, respectively, and moderate for OCT, with κ value of 0.40. Using panel consensus as reference standard, OCT had the highest discriminative ability, with an area under the curve (AUC) of 0.99 (95% 0.96–1.0) compared to photograph AUC 0.85 (95% 0.73–0.96) and VF AUC 0.86 (95% 0.76–0.96), suggestive of closer performance to that of a group of glaucoma specialists. CONCLUSIONS: Compared to VF and disc photography, SD-OCT, when used alone, had better internal agreement as well as better agreement with the consensus of clinicians using all available data. Future studies should evaluate best practices for SD-OCT interpretation.
format Online
Article
Text
id pubmed-5995486
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-59954862018-06-12 Technology and the Glaucoma Suspect Blumberg, Dana M. De Moraes, Carlos Gustavo Liebmann, Jeffrey M. Garg, Reena Chen, Cynthia Theventhiran, Alex Hood, Donald C. Invest Ophthalmol Vis Sci Articles PURPOSE: To determine and compare the diagnostic performance of spectral-domain optical coherence tomography (SD-OCT), stereoscopic disc photographs, and automated perimetry as assessed by a group of glaucoma specialists in differentiating individuals with early glaucoma from suspects. METHODS: Forty-six eyes (46 patients) with suspicious optic nerves had previously undergone SD-OCT scans, 24-2 visual fields (VFs), and optic disc photographs. The average VF mean deviation was −1.97 ± 2.09 (SD) dB. Four glaucoma specialists examined the 138 individual diagnostic tests and classified the patient as likely glaucomatous or nonglaucomatous based on the results of a single test. The diagnostic performances of each of the three tests were compared to a previously determined reference standard, based on the consensus of a separate panel of four glaucoma specialists who examined all three tests together. RESULTS: Among the four specialists, the interobserver agreement across the three diagnostic tests was poor for VF and photos, with kappa (κ) values of 0.13 and 0.16, respectively, and moderate for OCT, with κ value of 0.40. Using panel consensus as reference standard, OCT had the highest discriminative ability, with an area under the curve (AUC) of 0.99 (95% 0.96–1.0) compared to photograph AUC 0.85 (95% 0.73–0.96) and VF AUC 0.86 (95% 0.76–0.96), suggestive of closer performance to that of a group of glaucoma specialists. CONCLUSIONS: Compared to VF and disc photography, SD-OCT, when used alone, had better internal agreement as well as better agreement with the consensus of clinicians using all available data. Future studies should evaluate best practices for SD-OCT interpretation. The Association for Research in Vision and Ophthalmology 2016-07 /pmc/articles/PMC5995486/ /pubmed/27409509 http://dx.doi.org/10.1167/iovs.15-18931 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Articles
Blumberg, Dana M.
De Moraes, Carlos Gustavo
Liebmann, Jeffrey M.
Garg, Reena
Chen, Cynthia
Theventhiran, Alex
Hood, Donald C.
Technology and the Glaucoma Suspect
title Technology and the Glaucoma Suspect
title_full Technology and the Glaucoma Suspect
title_fullStr Technology and the Glaucoma Suspect
title_full_unstemmed Technology and the Glaucoma Suspect
title_short Technology and the Glaucoma Suspect
title_sort technology and the glaucoma suspect
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5995486/
https://www.ncbi.nlm.nih.gov/pubmed/27409509
http://dx.doi.org/10.1167/iovs.15-18931
work_keys_str_mv AT blumbergdanam technologyandtheglaucomasuspect
AT demoraescarlosgustavo technologyandtheglaucomasuspect
AT liebmannjeffreym technologyandtheglaucomasuspect
AT gargreena technologyandtheglaucomasuspect
AT chencynthia technologyandtheglaucomasuspect
AT theventhiranalex technologyandtheglaucomasuspect
AT hooddonaldc technologyandtheglaucomasuspect