Cargando…

Neuro-fuzzy inference system Prediction of stability indices and Sodium absorption ratio in Lordegan rural drinking water resources in west Iran

According to World Health Organization guidelines, corrosion control is an important aspect of safe drinking-water supplies. Water always includes ingredients, dissolved gases and suspended materials. Although some of these water ingredients is indispensable for human beings, these elements more tha...

Descripción completa

Detalles Bibliográficos
Autores principales: Takdastan, Afshin, Mirzabeygi (Radfard), Majid, Yousefi, Mahmood, Abbasnia, Abbas, Khodadadia, Rouhollah, Soleimani, Hamed, Mahvi, Amir Hossein, Naghan, Davood Jalili
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5996134/
https://www.ncbi.nlm.nih.gov/pubmed/29896514
http://dx.doi.org/10.1016/j.dib.2018.02.075
Descripción
Sumario:According to World Health Organization guidelines, corrosion control is an important aspect of safe drinking-water supplies. Water always includes ingredients, dissolved gases and suspended materials. Although some of these water ingredients is indispensable for human beings, these elements more than permissible limits, could be endanger human health. The aim of this study is to assess physical and chemical parameters of drinking water in the rural areas of Lordegan city, also to determine corrosion indices. This cross-sectional study has carried out with 141 taken samples during 2017 with 13 parameters, which has been analyzed based on standard method and to estimate the water quality indices from groundwater using ANFIS. Also with regard to standard conditions, results of this paper are compared with Environmental Protection Agency and Iran national standards. Five indices, Ryznar Stability Index (RSI), Langlier Saturation Index (LSI), Larson-Skold Index (LS), Puckorius Scaling Index (PSI), and Aggressive Index (AI) programmed by using Microsoft Excel software. Owing to its simplicity, the program, can easily be used by researchers and operators. Parameters included Sulfate, Sodium, Chloride, and Electrical Conductivity respectively were 13.5, 28, 10.5, and 15% more than standard level. The amount of Nitrate, in 98% of cases were in permissible limits and about 2% were more than standard level. Result of presented research indicate that water is corrosive at 10.6%,89.4%,87.2%,59.6% and 14.9% of drinking water supply reservoirs, according to LSI, RSI, PSI, LS and AI, respectively.