Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography
The composition of multicomponent determination by colorimetric titration is difficult. This complexity is easily overcome by using Gas Chromatography technique instead of wet method for multi-component mixture analysis. In Gas Chromatography, first the standard chart is prepared by using the known...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5996402/ https://www.ncbi.nlm.nih.gov/pubmed/29900261 http://dx.doi.org/10.1016/j.dib.2018.03.111 |
_version_ | 1783330844855762944 |
---|---|
author | Mekala, Mallaiah Goli, Venkat Reddy |
author_facet | Mekala, Mallaiah Goli, Venkat Reddy |
author_sort | Mekala, Mallaiah |
collection | PubMed |
description | The composition of multicomponent determination by colorimetric titration is difficult. This complexity is easily overcome by using Gas Chromatography technique instead of wet method for multi-component mixture analysis. In Gas Chromatography, first the standard chart is prepared by using the known amount sample concentration as the reference. Once calibration chart is prepared the unknown sample concentration easily measured by using the standard chart. In the present study a standard calibration chart developed for the four component system of acetic acid–methanol–methyl acetate–water. The samples were taken at various concentrations of all components and different chromatograms obtained under various concentrations respectively. The method of optimization was first carried out to get the sharp peaks of individual components and binary pairs also. By using those conditions, the multi components concentrations were estimated. From the present results, the area under gas chromatogram is linearly varying with mole% of the components compared to mass%. |
format | Online Article Text |
id | pubmed-5996402 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-59964022018-06-13 Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography Mekala, Mallaiah Goli, Venkat Reddy Data Brief Chemistry The composition of multicomponent determination by colorimetric titration is difficult. This complexity is easily overcome by using Gas Chromatography technique instead of wet method for multi-component mixture analysis. In Gas Chromatography, first the standard chart is prepared by using the known amount sample concentration as the reference. Once calibration chart is prepared the unknown sample concentration easily measured by using the standard chart. In the present study a standard calibration chart developed for the four component system of acetic acid–methanol–methyl acetate–water. The samples were taken at various concentrations of all components and different chromatograms obtained under various concentrations respectively. The method of optimization was first carried out to get the sharp peaks of individual components and binary pairs also. By using those conditions, the multi components concentrations were estimated. From the present results, the area under gas chromatogram is linearly varying with mole% of the components compared to mass%. Elsevier 2018-03-29 /pmc/articles/PMC5996402/ /pubmed/29900261 http://dx.doi.org/10.1016/j.dib.2018.03.111 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Chemistry Mekala, Mallaiah Goli, Venkat Reddy Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title | Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title_full | Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title_fullStr | Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title_full_unstemmed | Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title_short | Data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column Gas Chromatography |
title_sort | data on acetic acid–methanol–methyl acetate–water mixture analysised by dual packed column gas chromatography |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5996402/ https://www.ncbi.nlm.nih.gov/pubmed/29900261 http://dx.doi.org/10.1016/j.dib.2018.03.111 |
work_keys_str_mv | AT mekalamallaiah dataonaceticacidmethanolmethylacetatewatermixtureanalysisedbydualpackedcolumngaschromatography AT golivenkatreddy dataonaceticacidmethanolmethylacetatewatermixtureanalysisedbydualpackedcolumngaschromatography |