Cargando…

Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort

BACKGROUND: Heart rate variability (HRV) is an indicator of dynamic adaptability of the autonomic nervous system. Few interventions target upstream, cerebral cortex components of the heart–brain system for autonomic management. We report changes in HRV and baroreflex sensitivity (BRS), associated wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Shaltout, Hossam A., Lee, Sung W., Tegeler, Catherine L., Hirsch, Joshua R., Simpson, Sean L., Gerdes, Lee, Tegeler, Charles H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5996903/
https://www.ncbi.nlm.nih.gov/pubmed/29922641
http://dx.doi.org/10.3389/fpubh.2018.00116
_version_ 1783330968267915264
author Shaltout, Hossam A.
Lee, Sung W.
Tegeler, Catherine L.
Hirsch, Joshua R.
Simpson, Sean L.
Gerdes, Lee
Tegeler, Charles H.
author_facet Shaltout, Hossam A.
Lee, Sung W.
Tegeler, Catherine L.
Hirsch, Joshua R.
Simpson, Sean L.
Gerdes, Lee
Tegeler, Charles H.
author_sort Shaltout, Hossam A.
collection PubMed
description BACKGROUND: Heart rate variability (HRV) is an indicator of dynamic adaptability of the autonomic nervous system. Few interventions target upstream, cerebral cortex components of the heart–brain system for autonomic management. We report changes in HRV and baroreflex sensitivity (BRS), associated with use of a noninvasive, closed-loop, allostatic, computer-guided, acoustic stimulation neurotechnology. METHODS: Over 5 years, 220 subjects with heterogeneous neurological, cardiovascular, and psychophysiological conditions consecutively enrolled in a naturalistic, single-arm study exploring clinical effects associated with use of the neurotechnology. Of those, 202 completed the study protocol and 160 had recordings adequate to analyze HRV and BRS. Mean age was 44.0 (SD 19.4), with 130 women. Participants received a mean of 16.1 (5.2) sessions, over 24.2 days (23.3), with 9.5 (3.8) actual intervention days. Sessions included real-time analysis of brain electrical activity and software algorithm-guided translation of selected frequencies into patterns of acoustic stimulation (audible tones of variable pitch and timing), to facilitate auto-calibration of neural oscillations. Outcomes including 10-min supine, at-rest recordings of blood pressure and heart rate, and inventories for insomnia (ISI) and depression (CES-D or BDI-II), were obtained at baseline and 15.3 (16.7) days after the last session. RESULTS: Compared to baseline, significant increases (all p < 0.001) were observed for measures of HRV across all participants including the mean percentage change for SDNN 24.2% (SE 0.04), and RMSSD, 42.2% (0.08), and BRS [Sequence Up, 55.5% (0.09), Sequence Down, 77.6% (0.23), and Sequence All, 53.7% (0.07)]. Significant improvements were noted in SAP, MAP, and DAP, as well as natural log of HF, and total power. Self-reported ISI was reduced (ISI, −6.4 points, SD 5.6, p < 0.001). The proportion reporting clinically significant depressive symptoms reduced from 48.2% at baseline to 22.1% at follow-up. Linear regression showed that rightward asymmetry predicted lower SDNN (p = 0.02). Exploratory analysis showed a trend for improved balance of temporal lobe high-frequency amplitudes over the course of initial sessions. CONCLUSION: These findings indicate that use of a noninvasive, allostatic, closed-loop neurotechnology appears to have robust potential for public health efforts to support greater flexibility in autonomic cardiovascular regulation, through self-optimization of electrical activity at the level of the brain.
format Online
Article
Text
id pubmed-5996903
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-59969032018-06-19 Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort Shaltout, Hossam A. Lee, Sung W. Tegeler, Catherine L. Hirsch, Joshua R. Simpson, Sean L. Gerdes, Lee Tegeler, Charles H. Front Public Health Public Health BACKGROUND: Heart rate variability (HRV) is an indicator of dynamic adaptability of the autonomic nervous system. Few interventions target upstream, cerebral cortex components of the heart–brain system for autonomic management. We report changes in HRV and baroreflex sensitivity (BRS), associated with use of a noninvasive, closed-loop, allostatic, computer-guided, acoustic stimulation neurotechnology. METHODS: Over 5 years, 220 subjects with heterogeneous neurological, cardiovascular, and psychophysiological conditions consecutively enrolled in a naturalistic, single-arm study exploring clinical effects associated with use of the neurotechnology. Of those, 202 completed the study protocol and 160 had recordings adequate to analyze HRV and BRS. Mean age was 44.0 (SD 19.4), with 130 women. Participants received a mean of 16.1 (5.2) sessions, over 24.2 days (23.3), with 9.5 (3.8) actual intervention days. Sessions included real-time analysis of brain electrical activity and software algorithm-guided translation of selected frequencies into patterns of acoustic stimulation (audible tones of variable pitch and timing), to facilitate auto-calibration of neural oscillations. Outcomes including 10-min supine, at-rest recordings of blood pressure and heart rate, and inventories for insomnia (ISI) and depression (CES-D or BDI-II), were obtained at baseline and 15.3 (16.7) days after the last session. RESULTS: Compared to baseline, significant increases (all p < 0.001) were observed for measures of HRV across all participants including the mean percentage change for SDNN 24.2% (SE 0.04), and RMSSD, 42.2% (0.08), and BRS [Sequence Up, 55.5% (0.09), Sequence Down, 77.6% (0.23), and Sequence All, 53.7% (0.07)]. Significant improvements were noted in SAP, MAP, and DAP, as well as natural log of HF, and total power. Self-reported ISI was reduced (ISI, −6.4 points, SD 5.6, p < 0.001). The proportion reporting clinically significant depressive symptoms reduced from 48.2% at baseline to 22.1% at follow-up. Linear regression showed that rightward asymmetry predicted lower SDNN (p = 0.02). Exploratory analysis showed a trend for improved balance of temporal lobe high-frequency amplitudes over the course of initial sessions. CONCLUSION: These findings indicate that use of a noninvasive, allostatic, closed-loop neurotechnology appears to have robust potential for public health efforts to support greater flexibility in autonomic cardiovascular regulation, through self-optimization of electrical activity at the level of the brain. Frontiers Media S.A. 2018-04-25 /pmc/articles/PMC5996903/ /pubmed/29922641 http://dx.doi.org/10.3389/fpubh.2018.00116 Text en Copyright © 2018 Shaltout, Lee, Tegeler, Hirsch, Simpson, Gerdes and Tegeler. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Public Health
Shaltout, Hossam A.
Lee, Sung W.
Tegeler, Catherine L.
Hirsch, Joshua R.
Simpson, Sean L.
Gerdes, Lee
Tegeler, Charles H.
Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title_full Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title_fullStr Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title_full_unstemmed Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title_short Improvements in Heart Rate Variability, Baroreflex Sensitivity, and Sleep After Use of Closed-Loop Allostatic Neurotechnology by a Heterogeneous Cohort
title_sort improvements in heart rate variability, baroreflex sensitivity, and sleep after use of closed-loop allostatic neurotechnology by a heterogeneous cohort
topic Public Health
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5996903/
https://www.ncbi.nlm.nih.gov/pubmed/29922641
http://dx.doi.org/10.3389/fpubh.2018.00116
work_keys_str_mv AT shaltouthossama improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT leesungw improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT tegelercatherinel improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT hirschjoshuar improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT simpsonseanl improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT gerdeslee improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort
AT tegelercharlesh improvementsinheartratevariabilitybaroreflexsensitivityandsleepafteruseofclosedloopallostaticneurotechnologybyaheterogeneouscohort